November 29, 2010: Busted laser safety box: ([https://hallcweb.jlab.org/hclog/1012_archive/101208141812.html log entry]).
+
November 5, 2010: First photon detector removed: ([https://hallcweb.jlab.org/hclog/1011_archive/101105154946.html hclog entry]). The second one must have been installed the same day or shortly thereafter.
  
Decemebr 7, 2010: Replaced Arshak's paddle with Moller scint. ([https://hallcweb.jlab.org/hclog/1012_archive/101207223030.html log entry]). I believe a second scintillator was hooked up to channel 11 at the same time.
+
November 19, 2010: Mark added 1 mm of lead in front of the photon detector: ([https://hallcweb.jlab.org/hclog/1011_archive/101119165813.html hclog entry]).
  
Decemebr 8, 2010: Locked cavity in opposite laser helicity ([https://hallcweb.jlab.org/hclog/1012_archive/101208141812.html log]). Can't find log entry about restoration of original helicity - I'm pretty sure it was the next day.
+
November 29, 2010: Busted laser safety box: ([https://hallcweb.jlab.org/hclog/1012_archive/101208141812.html hclog entry]).
  
December 9, 2010: Removed gamma-det. HV from patch ([https://hallcweb.jlab.org/hclog/1012_archive/101209154450.html log entry])
+
December ??, 2010: At some poitn this month, we stopped running the signal going into the FADC through the NIM FIFO, and ran it thorugh a passive 50:50 splitter instead. I can't remember when this happened and there was no log entry.
 +
 
 +
December 7, 2010: Replaced Arshak's paddle with Moller scint. ([https://hallcweb.jlab.org/hclog/1012_archive/101207223030.html hclog entry]). I believe a second scintillator was hooked up to channel 11 at the same time.
 +
 
 +
December 8, 2010: Locked cavity in opposite laser helicity ([https://hallcweb.jlab.org/hclog/1012_archive/101208141812.html hclog]). Can't find log entry about restoration of original helicity - I'm pretty sure it was the next day.
 +
 
 +
December 9, 2010: Removed gamma-det. HV from patch ([https://hallcweb.jlab.org/hclog/1012_archive/101209154450.html hclog entry])
 +
 
 +
January 6, 2011: Placed 2 mm lead in front of photon detector: ([https://hallcweb.jlab.org/hclog/1101_archive/110106160035.html hclog entry]).
 +
 
 +
January 13, 2011: I checked the passive splitter Mark made ([https://qweak.jlab.org/elog/Photon+Detector/39 elog entry]). The long delay cable was removed that night and the timing adjusted ([https://hallcweb.jlab.org/hclog/1101_archive/110114015720.html hclog entry]). NOTE: it's not clear we have any useful samples once this change was done until January 26, when Wouter and Juan Carlos looked at the timing again.
 +
 
 +
January 18, 2011: Removed 1 mm lead from photon detector, now just 1 mm: ([https://hallcweb.jlab.org/hclog/1101_archive/110106160035.html hclog entry]).
 +
 
 +
February 23, 2011: Removed passive splitter - replaced with linear FAN-IN/FAN-OUT: ([https://hallcweb.jlab.org/hclog/1102_archive/110223171127.html hclog entry]).

Latest revision as of 14:17, 1 March 2011

Hardware, configuration changes during Q-Weak running

November 5, 2010: First photon detector removed: (hclog entry). The second one must have been installed the same day or shortly thereafter.

November 19, 2010: Mark added 1 mm of lead in front of the photon detector: (hclog entry).

November 29, 2010: Busted laser safety box: (hclog entry).

December ??, 2010: At some poitn this month, we stopped running the signal going into the FADC through the NIM FIFO, and ran it thorugh a passive 50:50 splitter instead. I can't remember when this happened and there was no log entry.

December 7, 2010: Replaced Arshak's paddle with Moller scint. (hclog entry). I believe a second scintillator was hooked up to channel 11 at the same time.

December 8, 2010: Locked cavity in opposite laser helicity (hclog). Can't find log entry about restoration of original helicity - I'm pretty sure it was the next day.

December 9, 2010: Removed gamma-det. HV from patch (hclog entry)

January 6, 2011: Placed 2 mm lead in front of photon detector: (hclog entry).

January 13, 2011: I checked the passive splitter Mark made (elog entry). The long delay cable was removed that night and the timing adjusted (hclog entry). NOTE: it's not clear we have any useful samples once this change was done until January 26, when Wouter and Juan Carlos looked at the timing again.

January 18, 2011: Removed 1 mm lead from photon detector, now just 1 mm: (hclog entry).

February 23, 2011: Removed passive splitter - replaced with linear FAN-IN/FAN-OUT: (hclog entry).