One edge of the detector is placed 0.5 cm from the primary beam and the location is 4'' in front of the 4th dipole.
+
One edge of the detector is placed 0.5 cm from the primary beam and the location is 4inches in front of the 4th dipole.

Revision as of 17:06, 7 January 2010

 El det syst.png


  • The electron detector is moved in and out of the beam by the motion system showed below:
 El det vac motion.png


  • The electron detector is composed of four 2.1cmx2.1cm planes separated by 1cm and staggered 100 µm with respect to each other. Each plane contains 96 horizontal diamond strips (polycrystalline CVD diamond). Each strip is 180 µm wide and they are separated by a 20 µm gap. Metalization was done on each plane with Titanium-Platinum-Gold (TiPtAu). The carrier boards are in Ceramic (alumina).
 El det diamond.png

One edge of the detector is placed 0.5 cm from the primary beam and the location is 4inches in front of the 4th dipole.