E-Detector Motion System

From PolWiki
Revision as of 15:26, 19 August 2010 by Narayan (talk | contribs)
Jump to navigationJump to search
  • The electron detector is connected to the QWAD using the custom made Flex-cable. The detector is placed inside the vacuum-can whereas the QWAD is placed outside using appropriate flanges used between the Flex-cable and the QWAD. The connection between e-detector and the QWAD (if the vacuum - can was transparent) can be depicted as in the attached picture.
  • The electron detector vacuum - can has a motion mechanism to allow us to move the detector vertically in and out of the beam along with the ability to rotate the detector facing the beam. A schematic view of the assembly can be seen here.
  • We are using a stepping motor identified as KML062S04 for vertical motion ( data sheet ) of detector using a MDC accuator ( specifications ). This motor is being controlled by a single axis IDC Controller (User Manual)

Current Controller Settings:

Current: 1.5A 
Resolution: 18000 
Inductance: 16 mH 
Direction: positive 
Distance Unit: inch
Velocity: inch/s
Acceleration Unit: in/s^2
Gear Ratio: (GR) = 25:1