Moller Polarimeter/NPS

From PolWiki
Jump to navigationJump to search

Summary Plot of NPS Moller Measurements

Nps by day 23jan2024.png

Global fit to Hall A, B, C Moller Measurements + Mott Measurement

Nps global fit 23jan2024.png

Moller measurement summaries

Note that this is the first experiment to use the new cryogen-free superconducting target magnet.

September 22, 2023

  • IHWP IN: P = -80.06 +/- 0.54 %
  • IHWP OUT: P = 80.55 +/- 0.58 %
  • Tune up at 5 pass. Had a hard time seeing scintillators - thought they were gain matched ok (but maybe they weren't), so thought there might be problems with DAQ.
    • Q1 = 126.86 A
    • Q2/Q3 = -1318.0 A
    • Final collimator settings: https://logbooks.jlab.org/entry/4185462, NOTE: these are wrong - chose wrong collimator 3 setting!
      • 1/2 = -0.60/-0.60
      • 3/4 = -1.80/-2.40
      • 5=0.0
      • 6/7=-2.90/-2.80
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1787      -         -           -48.3     -               First run after gain matching calorimeters, 1 um foil
1788      -         -           -48.3     -               Changed ADC/TDC prescale
1789      -         -           -48.3     -               All scintillators turned on
1790      -         -           -48.3     -               Q3 reduced from 1338 to 1318 A
1791      -         -           -48.3     -               Changed memory delay from 4->3
1792      -         -           -48.3     -               Changed memory delay from 3->5
1793      -         -           -48.3     -               junk
1794      -         -           -48.3     -               After rebooting all
1795      -         -           -48.3     -               Added delay to memory strobe (16 ns, 8 ns)
1796      -         -           -48.3     -               Changed defaults in CRL
1797      -         -           -48.3     -               Set memory delay to 7 (WSI was unplugged - woops)
1798      -         -           -48.3     -               Delay=7
1799      -         -           -48.3     -               Delay=3
1800      -         -           -48.3     -               Delay=2
1801      -         -           -48.3     -               Delay=4, 4 um target
1802      -         -           -48.3     -               changed prescale, before collimator scan
1803     -79.93     0.77        -48.3     10539.04        IHWP=IN
1804     -80.18     0.77        -48.3     10538.97        IHWP=IN
1805      80.18     0.82        -48.3     10538.83        IHWP=OUT
1806      78.62     2.84        -48.3     10539.53        IHWP=OUT
1807      81.13     0.86        -48.3     10539.14        IHWP=OUT

October 8, 2023

  • IHWP IN: P = -81.03 +/- 0.54 %
  • IHWP OUT: P = 81.21 +/- 0.57 %
  • Attempted to improve gain matching scintillators. Performed short Q2/Q3 scan (rates). Accidentally used wrong collimator positions:
    • 1/2=-1.7 cm
    • 3/4=-2.5 cm
    • 7/8=-2.4 cm
  • Summary log entry: https://logbooks.jlab.org/entry/4195556
  • Runs on 10/8/2023 (QE=0.2791%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1823      -         -           -48.3     -               DAQ test
1824      -         -           -48.3     -               Gain matched Left-5 triggered on coins, then used scin trigger for others
1825      -         -           -48.3     -               Increased all scintillator HV 50 V - looks a little better
1826      -         -           -48.3     -               Increased L4 and L9 even more. 1st point of Q3 (=1318 A)scan (4.7 kHz/uA)
1827      -         -           -48.3     -               Q3 scan: 1298 A (4.7 kHz/uA)
1828      -         -           -48.3     -               Q3 scan: 1278 A (4.5 kHz/uA)
1829      -         -           -48.3     -               Q3 scan: 1338 A (4.5 kHz/uA)
1830      -         -           -48.3     -               Q3 scan: 1318 A (4.7 kHz/uA)
1831     -81.33     0.77        -48.3     10538.73        IHWP=IN
1832     -80.73     0.77        -48.3     10538.69        IHWP=IN
1833      -         -           -48.3     -               IHWP=OUT (junk - Hall A performing NMR)
1834      81.53     1.51        -48.3     10538.66        IHWP=OUT helicity error - only got part of run
1835      81.25     0.78        -48.3     10538.71        IHWP=OUT
1836      81.00     1.00        -48.3     10538.71        IHWP=OUT
1837      -         -           -48.3     -               Bleed-thru run (laser off) coin rate=1 Hz

October 17, 2023

  • IHWP IN: P = -80.34 +/- 0.52 %
  • IHWP OUT: P = 80.92 +/- 0.53 %
  • Had HV troubles at beginning - had to load in backup from A1n. Found the scintillators had been set at very voltages. Finally saw good tune plot.
  • Did another collimator scan
    • 1/2 = -1.0/-1.0
    • 3/4 = -2.4/-2.4
    • 6/7 = -2.6/-2.4
  • Summary log entry: https://logbooks.jlab.org/entry/4201825
  • Runs on 10/17/2023 (QE = 0.2563%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1839      -         -           -48.3     -               DAQ test
1840      -         -           -48.3     -               Tune plot run
1841     -80.43     0.73        -48.3     10537.67        IHWP=IN
1842     -80.15     0.75        -48.3     10537.72        IHWP=IN
1843     -83.04     3.72        -48.3     10537.69        IHWP=IN, Helicity error
1844      81.64     0.75        -48.3     10537.84        IHWP=OUT
1845      80.20     0.75        -48.3     10537.74        IHWP=OUT
1846      81.78     2.17        -48.3     10537.70        IHWP=OUT

October 27, 2023

  • IHWP IN: P = -80.58 +/- 0.53 %
  • IHWP OUT: P = 80.71 +/- 0.58 %
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1847      -         -           -48.3     -               DAQ test
1848      -         -           -48.3     -               Tune plot run
1849      80.27     0.76        -48.3     10537.80        IHWP=OUT
1850      81.21     0.81        -48.3     10537.63        IHWP=OUT
1851     -81.52     0.74        -48.3     10537.69        IHWP=IN
1852     -79.61     0.75        -48.3     10537.72        IHWP=IN
1853      -         -           -48.3     -               Bleed thru: 0.5-3 Hz (4.6 kHz signal)

November 6, 2023

  • IHWP IN: P = -78.53 +/- 0.55 %
  • IHWP OUT: P = 78.45 +/- 55 %
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1856      -         -           -15.3     -               Tune plot run
1857      -         -           -15.3     -               junk
1858      -         -           -15.3     -               junk - beam needed to be resteered
1859     -79.37     0.80        -15.3     10539.66        IHWP=IN
1860     -77.80     0.75        -15.3     10539.62        IHWP=IN
1861      78.00     0.78        -15.3     10539.62        IHWP=OUT
1862      78.88     0.77        -15.3     10537.72        IHWP=OUT

November 18, 2023

  • HWP=OUT: P=68.10 +/- 0.53 %
  • IHWP=IN: P=-68.27 +/- 0.52 %
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1863      -         -           -30.0      -              Tune run: Q3=910 A
1864      -         -           -30.0      -              Tune run: Q3=920 A
1865      -         -           -30.0      -              Tune run: Q3=915 A
1866      -         -           -30.0      -              Tune run: Q3=910 A
1867      -         -           -30.0      -              Helicity errors, junk
1869      -         -           -30.0      -              Helicity errors, junk
1869      -         -           -30.0      -              Helicity errors, junk
1870      68.22     0.75        -30.0      8457.27        IHWP=OUT
1871      67.96     0.76        -30.0      8456.97        IHWP=OUT
1872     -67.83     0.76        -30.0      8458.16        IHWP=IN
1873     -68.65     0.71        -30.0      8456.35        IHWP=IN

December 6, 2023

  • IHWP=IN: P=-86.23 +/- 0.50 %
  • IHWP=OUT: P=86.68 +/- 0.51 %
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1877      -         -           -50.0      -              Tune run
1878     -85.35     0.68        -50.0      8453.81        IHWP=IN
1879     -87.24     0.73        -50.0      8454.24        IHWP=IN
1880      86.29     0.71        -50.0      8454.54        IHWP=OUT
1881      87.09     0.72        -50.0      8453.86        IHWP=OUT

December 13, 2023

  • IHWP=IN: N/A
  • IHWP=OUT: P= 87.53 +/- 0.51 %
  • IHWP=OUT measurement only
  • Runs on 12/13/2023 (QE = 0.4653%.)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1883      -         -           -50.0      -              Tune run
1884      87.00     0.73        -50.0      8453.36        IHWP=OUT
1885      88.04     0.72        -50.0      8454.49        IHWP=OUT

January 22, 2024

  • IHWP=IN: P=-77.99 +/- 0.44 %
  • IHWP=OUT: P= 78.49 +/- 0.44 %
  • Beam energy drifted about 4 MeV during Moller running from production value
  • Runs on 1/22/2023 (QE = 1.0025%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1887      -         -           -13.2      -              Tune run
1888      79.99     0.77        -13.2      10539.65       IHWP=OUT
1889      77.57     0.68        -13.2      10539.97       IHWP=OUT
1890      78.52     1.09        -13.2      10540.36       IHWP=OUT, noticed 2nd scaler bank wasn't counting, reset crate
1891      77.56     1.31        -13.2      10540.27       IHWP=OUT
1892     -78.42     0.71        -13.2      10540.18       IHWP=IN
1893     -78.33     0.71        -13.2      10541.54       IHWP=IN
1894      -         -           -13.2      -              Junk
1895     -76.68     0.93        -13.2      10541.72       IHWP=IN
1896      -         -           -13.2      -              Bleedthru check - none

February 2, 2024

  • IHWP=IN: P= -80.96 +/- 0.50 %
  • IHWP=OUT: P= 80.98 +/- 0.48%
  • Used SLM energy lock
  • Runs on 2/2/2024 (QE = 0.9734%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1898      -         -           -13.2      -              Tune run
1899     -81.40     0.68        -13.2      10536.76       IHWP=IN
1900     -82.35     1.47        -13.2      10536.08       IHWP=IN, energy lock was off
1901      -         -           -13.2      -              Junk
1902     -81.69     1.35        -13.2      10536.59       IHWP=IN, end for steering
1903     -79.92     0.87        -13.2      10536.64       IHWP=IN
1904      81.49     0.69        -13.2      10536.31       IHWP=OUT
1905      -         -           -13.2      -              Junk (helicity panic)
1906      80.50     0.67        -13.2      10536.49       IHWP=OUT

February 15, 2024

  • IHWP=IN: P= -81.68 +/- 0.59%
  • IHWP=OUT: P= 82.19 +/- 0.54%
  • Runs on 2/15/2024 (QE = 0.9617%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1908      -         -           -47.6      -              DAQ test
1909      -         -           -47.6      -              Tune run
1910      82.26     0.75        -47.6      10538.88       IHWP=OUT
1911      -         -           -47.6      -              Short run - energy drifting 
1912      82.12     0.78        -47.6      10540.01       IHWP=OUT
1913     -81.84     0.90        -47.6      10538.94       IHWP=IN  
1914     -81.57     0.77        -47.6      10539.70       IHWP=IN           

March 5, 2024

  • IHWP=IN: P=-79.79 +/- 0.55%
  • IHWP=OUT: P=80.44 +/- 0.54%
  • Runs on 3/5/2024 (QE = 0.9143%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1915      -         -           -47.6      -              DAQ test  
1916      -         -           -47.6      -              Tune run  
1917     -79.42     0.77        -47.6     10536.48        IHWP=IN      
1918     -80.16     0.78        -47.6     10536.46        IHWP=IN 
1919      80.46     0.77        -47.6     10536.69        IHWP=OUT
1920      80.42     0.75        -47.6     10536.51        IHWP=OUT         

March 12, 2024

  • IHWP=IN: P=-84.05 +/- 0.41%
  • IHWP=OUT: P=84.29 +/- 0.41%
  • First measurement at 3 pass
  • Runs on 3/12/2024 (QE = 0.8473%)
Run	  Pol (%)   Error (%)	Hwien     HALC:p(MeV)     Comment
1921      -         -           -47.6      -              DAQ test  
1922      -         -           -47.6      -              Tune run  
1923      83.42     0.66         10.0      6368.68        IHWP=OUT  
1924      83.87     0.71         10.0      6368.63        IHWP=OUT 
1925      85.74     0.73         10.0      6368.54        IHWP=OUT 
1926     -82.83     0.69         10.0      6368.51        IHWP=IN 
1927     -85.42     0.72         10.0      6368.50        IHWP=IN 
1928     -84.00     0.72         10.0      6368.51        IHWP=IN