Shift crew procedures
From PolWiki
Compton Procedures Sheet (short version for shift workers)
General Compton running:
- At least once every hour restart a new CODA run. CODA should be open on one of the desktops of ccomptl1.
- At least once every hour check the status of the HV. If a trip occurred, see below.
- Check whether the laser is still flipping (EPICS channel cComptCavityPower).
- This should be obvious from the camera as well. If not flipping, call an expert. This EPICS PV should be visible on the desktop of Striptools on ccomptl1.
- Monitor the background scintillator rates. cComptScintRateNorm should stay below 200 Hz/uA.
After a photon detector HV trip:
- Check that the normalized rate on the background scintillator (EPICS channel cComptScintRateNorm, or manually normalize hcrate14) is still below 150 Hz/uA (200 Hz/uA is tolerable, <150 Hz/uA is "good").
- This EPICS PV should be visible on the desktop of Striptools on ccomptl1. If not, call an expert.
- This EPICS PV should be visible on the desktop of Striptools on ccomptl1. If not, call an expert.
- Wait 5 minutes after the trip and turn on the HV on the photon detector to 1600 V (channel PhotonDet_6).
- The HV controls should be open on one of the ccomptl1 desktops. If not log on to cdaql4 as cvxwrks and cd to $EPSHV/tk then run /HV_compton.tcl and turn on PhotonDet_6.
- The HV controls should be open on one of the ccomptl1 desktops. If not log on to cdaql4 as cvxwrks and cd to $EPSHV/tk then run /HV_compton.tcl and turn on PhotonDet_6.
- If the photon detector HV trips again within 15 minutes, call an expert.
Experts on call
Experts: Call or page in the order below. Wait a few minutes before moving on to the next name on the list.
- Dave Gaskell, pager gaskelld-page@jlab.org, cell 719-5482
- Don Jones, cell 768-1148
- Wouter Deconinck, pager 238-4235, cell 927-2413
- Amrendra Narayan (electron detector) cell 952-6126