== Source code == | == Source code == | ||
− | *[http://www.jlab.org/Hall-C/upgrade/ | + | *[http://www.jlab.org/Hall-C/upgrade/mc_shms_single_april2012.tar.gz mc_shms_single_april2012.tar.gz] is the tarball. |
* On JLab ifarm64 machines execute : "setup cernlib/2005" before doing "make" | * On JLab ifarm64 machines execute : "setup cernlib/2005" before doing "make" | ||
+ | |||
==Comments on code == | ==Comments on code == | ||
*Designed to be used for studying optics and acceptance of the SHMS. | *Designed to be used for studying optics and acceptance of the SHMS. |
Revision as of 10:49, 5 April 2012
Source code
- mc_shms_single_april2012.tar.gz is the tarball.
- On JLab ifarm64 machines execute : "setup cernlib/2005" before doing "make"
Comments on code
- Designed to be used for studying optics and acceptance of the SHMS.
- Materials hit when multiple scattering flag turned on.
- Target
- When target length greater than 3cm, assumes a beer can target with diameter of 3.37cm and wall thickness of 0.005 inches
- Need to enter the radiation length of target material in the input file.
- Scattering chamber window is 0.016inches of aluminum
- 15 cm of air between scattering chamber and snout. Since snout is not designed this is a guess.
- SHMS entrance window is 0.020 inches of aluminum.
- SHMS exit window is 0.020 inches of aluminum.
- Three options for after the SHMS exit window
- Argon/Neon Cerenkov. Set the cer_flag=1 ( line 22 in input file). The vac_flag ( line 23 in input file) is ignored.
- Helium bag replaces the Argon/Neon Cerenkov. This is the assumed mode of option at low momentum. Set the cer_flag=0 ( line 22 in input file) and set the vac_flag=0 ( line 23 in input file).
- For study, vacuum pipe replaces the Argon/Neon Cerenkov. Set the cer_flag=0 ( line 22 in input file) and set the vac_flag=1 ( line 23 in input file).
- SHMS wire chambers
- Target
- SHMS wire chamber resolution is 200 microns
- SHMS collimator is in place and cuts events.
- Events cut if outside area of drift chambers, S1 and S2 scintillators and the calorimeter in mc_shms_hut.f.