Difference between revisions of "Shift Checklist Help"
From HallCWiki
Jump to navigationJump to searchLine 3: | Line 3: | ||
= Shift Checklist Help = | = Shift Checklist Help = | ||
* The [[How-to]] page is extremely helpful. Use Firefox's "Page search" to help find what you are looking for. | * The [[How-to]] page is extremely helpful. Use Firefox's "Page search" to help find what you are looking for. | ||
− | * There is also an [https://hallcweb.jlab.org/document/Checklist/CurrentChecklist.pdf older Shift Checklist help file], which may help to locate items. (But it is a stale document.) | + | * There is also an [https://hallcweb.jlab.org/document/Checklist/CurrentChecklist.pdf older Shift Checklist help file], which may help to locate items. (But it is a stale document.) Below is an updated table. |
+ | |||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! What | ||
+ | ! Where to find it | ||
+ | ! How to do it | ||
+ | |- | ||
+ | | DATE (day-month-year) | ||
+ | | As given by Run Control | ||
+ | | Enter as DD-MM-YY | ||
+ | |- | ||
+ | | Time (24-hour clock) | ||
+ | | As given by Run Control | ||
+ | | Write the time into the cell | ||
+ | |- | ||
+ | | Your Name | ||
+ | | As given by your parents | ||
+ | | Write legibly | ||
+ | |- | ||
+ | | colspan="3" style="text-align: center;" | '''Beam Conditions from Overview Screen, DAQ, MEDMs, and Scalers''' | ||
+ | |- | ||
+ | | Beam Energy (MeV) | ||
+ | | This '''summary screen''' should already be displayed on the wall. If not, do | ||
+ | ''jmenu'' → ''Operations'' → ''WallMenu'' | ||
+ | | Write down the Hall C beam energy | ||
+ | |- | ||
+ | | Beam Current (uA) | ||
+ | | '''Same as above''' | ||
+ | | MPS and Hall C BCM readings should be similar. Record the | ||
+ | reading | ||
+ | |- | ||
+ | |Beam position lock on? | ||
+ | | Use ''jmenu'' and search for 'lock.' Then choose 'Orbit Locks Normal View | ||
+ | and look for 'HallCOrb.' It should be in green and show 'Running.' | ||
+ | | Write 'yes' or 'no' in the cell | ||
+ | |- | ||
+ | |Beam energy lock on? | ||
+ | | Use ''jmenu'' and search for 'lock.' Then choose 'Energy Locks.' | ||
+ | | Write down the three colors: one for '0R, 1A, 2A.' (They should all be green. This indicates 'yes.') | ||
+ | |- | ||
+ | | colspan="3" style="text-align: center;" | '''DAQ Quantities''' | ||
+ | |- | ||
+ | |HMS Trigger Rate | ||
+ | | On the CODA GUI Screen, next to the appropriate prescaler value (ps1 through ps6). | ||
+ | | Record the typical instantaneous rate | ||
+ | |- | ||
+ | |SHMS Trigger Rate | ||
+ | | On the CODA GUI Screen, next to the appropriate prescaler value (ps1 through ps6). | ||
+ | | Record the typical instantaneous rate | ||
+ | |} |
Revision as of 12:32, 1 October 2019
Direct link to the Hall C Shift Checklist
Shift Checklist Help
- The How-to page is extremely helpful. Use Firefox's "Page search" to help find what you are looking for.
- There is also an older Shift Checklist help file, which may help to locate items. (But it is a stale document.) Below is an updated table.
What | Where to find it | How to do it |
---|---|---|
DATE (day-month-year) | As given by Run Control | Enter as DD-MM-YY |
Time (24-hour clock) | As given by Run Control | Write the time into the cell |
Your Name | As given by your parents | Write legibly |
Beam Conditions from Overview Screen, DAQ, MEDMs, and Scalers | ||
Beam Energy (MeV) | This summary screen should already be displayed on the wall. If not, do
jmenu → Operations → WallMenu |
Write down the Hall C beam energy |
Beam Current (uA) | Same as above | MPS and Hall C BCM readings should be similar. Record the
reading |
Beam position lock on? | Use jmenu and search for 'lock.' Then choose 'Orbit Locks Normal View
and look for 'HallCOrb.' It should be in green and show 'Running.' |
Write 'yes' or 'no' in the cell |
Beam energy lock on? | Use jmenu and search for 'lock.' Then choose 'Energy Locks.' | Write down the three colors: one for '0R, 1A, 2A.' (They should all be green. This indicates 'yes.') |
DAQ Quantities | ||
HMS Trigger Rate | On the CODA GUI Screen, next to the appropriate prescaler value (ps1 through ps6). | Record the typical instantaneous rate |