Difference between revisions of "RC Meeting, Thursday, January 13, 2022"

From HallCWiki
Jump to: navigation, search
 
(9 intermediate revisions by the same user not shown)
Line 28: Line 28:
 
* [https://jlab-org.zoomgov.com/j/1611843361?pwd=YU55WVVwVS9ZVDEvT1I5M1VIbnJyQT09 OPS 7:45 RC meeting Zoom link]
 
* [https://jlab-org.zoomgov.com/j/1611843361?pwd=YU55WVVwVS9ZVDEvT1I5M1VIbnJyQT09 OPS 7:45 RC meeting Zoom link]
 
* [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 OPS daily 8:00 meeting and Wed 1:30 new Zoom link]
 
* [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 OPS daily 8:00 meeting and Wed 1:30 new Zoom link]
 +
* Zoom link for remote shifts: https://jlab-org.zoomgov.com/j/1613876340?pwd=WG1pOFVsaXdGaHJvbG15QVBjL3k5Zz09
  
  
 
= Announcements =
 
= Announcements =
* '''Social distancing requirements back in place as of yesterday.''' Please maintain a separation of 6 feet during shifts.
+
* '''Social distancing requirements back in place.''' Please maintain a separation of 6 feet during shifts.
* See updated guidance on COVID isolation and quarantine protocols: https://www.jlab.org/memo/jlab-covid-19-isolation-and-quarantine-requirements
+
* See updated guidance on JLab COVID-19 isolation and quarantine protocols: https://www.jlab.org/memo/jlab-covid-19-isolation-and-quarantine-requirements
** Communicate with Occupational Medicine if you have COVID symptoms, a positive test, or have been exposed (jnewman@jlab.org or jbanks@jlab.org)
+
** Communicate with Occupational Medicine if you have COVID-19 symptoms, have tested positive for COVID-19, or have been exposed to someone who has tested positive for COVID-19:  (jnewman@jlab.org or jbanks@jlab.org).
 +
* Please keep an eye on the HMS NMR during shift.  Due to the NMR locking instability, the alarm has been been disabled, so slow drifts of the NMR signal may be missed.
  
 
= Current Status =
 
= Current Status =
Line 39: Line 41:
  
 
* SHMS Q1 lead flow controller replaced yesterday (thanks Heidi and Jerry): https://logbooks.jlab.org/entry/3970550
 
* SHMS Q1 lead flow controller replaced yesterday (thanks Heidi and Jerry): https://logbooks.jlab.org/entry/3970550
* Dave Meekins found an issue with target - heat load issue improved: https://logbooks.jlab.org/entry/3970600
+
* Dave Meekins found an issue with target - heat load issue improved (but not totally resolved): https://logbooks.jlab.org/entry/3970600
 
* Started production after end of Controlled Access
 
* Started production after end of Controlled Access
** Took a little time for MCC to deliver required current
+
** Took a little time for MCC to deliver requested current
 
** Current limited to 42 uA due to SHMS singles rates: https://logbooks.jlab.org/entry/3970746
 
** Current limited to 42 uA due to SHMS singles rates: https://logbooks.jlab.org/entry/3970746
 
** Have ~2500 good e-pi evens at this setting (Q2=3.85 W=3.07, low epsilon, LH2)
 
** Have ~2500 good e-pi evens at this setting (Q2=3.85 W=3.07, low epsilon, LH2)
Line 58: Line 60:
 
* With LHe alarms it is good to check the cameras for plumes. If no plume and it is below the LO alarm and above LOLO then monitor with a plot and halog the problem.
 
* With LHe alarms it is good to check the cameras for plumes. If no plume and it is below the LO alarm and above LOLO then monitor with a plot and halog the problem.
 
* With LNitrogen alarms are not that critical. Just need to start monitoring the problem with plot and Halog.
 
* With LNitrogen alarms are not that critical. Just need to start monitoring the problem with plot and Halog.
 +
* HMS NMR is not locking stably - the alarm is turned off.  Please check on the NMR readback (while it is locked) intermittently to make sure the HMS dipole field is not drifting,
  
 
= Current Issues =
 
= Current Issues =
* Vertical beam position on target has changed a little - will ask Dave Meekins to adjust target ladder positions when beam returns
+
* Vertical beam position on target has changed a little: Dave Meekins is not concerned about an offset of this size (<0.5 mm).
 
* There is a rotation issue that has come up if moving HMS between 19 to 25 degrees. It usually gets stuck around this range, please be wary of this issue. We will likely skip settings in this range if this drive controller error cannot be solved. For singles it will not be a big deal to skip settings for HMS at those angles. We need a longer access to address this issue.
 
* There is a rotation issue that has come up if moving HMS between 19 to 25 degrees. It usually gets stuck around this range, please be wary of this issue. We will likely skip settings in this range if this drive controller error cannot be solved. For singles it will not be a big deal to skip settings for HMS at those angles. We need a longer access to address this issue.
 
*The Raster Coil pair Ax and Ay are off
 
*The Raster Coil pair Ax and Ay are off
Line 72: Line 75:
  
 
= Planned Accesses to the Hall =
 
= Planned Accesses to the Hall =
* Controlled access today for target cooldown
+
* None
  
 
= Planned Accelerator Configuration Changes =
 
= Planned Accelerator Configuration Changes =

Latest revision as of 11:17, 13 January 2022

RC Meeting Information

RC Daily Meetings are at 10 AM, remote

  • Zoom remote connection information:
 Join ZoomGov Meeting
 https://jlab-org.zoomgov.com/j/1607100885?pwd=ZFBsRTFsYm5Zb0laZ0tyZXNjcEE0QT09
 Meeting ID: 160 710 0885
 Passcode: 595071
 One tap mobile
 +16692545252,,1607100885# US (San Jose)
 +16468287666,,1607100885# US (New York)
 Dial by your location
       +1 669 254 5252 US (San Jose)
       +1 646 828 7666 US (New York)
       +1 669 216 1590 US (San Jose)
       +1 551 285 1373 US
       833 568 8864 US Toll-free
 Meeting ID: 160 710 0885
 Find your local number: https://jlab-org.zoomgov.com/u/ab2CekLXgQ

Useful Links


Announcements

  • Social distancing requirements back in place. Please maintain a separation of 6 feet during shifts.
  • See updated guidance on JLab COVID-19 isolation and quarantine protocols: https://www.jlab.org/memo/jlab-covid-19-isolation-and-quarantine-requirements
    • Communicate with Occupational Medicine if you have COVID-19 symptoms, have tested positive for COVID-19, or have been exposed to someone who has tested positive for COVID-19: (jnewman@jlab.org or jbanks@jlab.org).
  • Please keep an eye on the HMS NMR during shift. Due to the NMR locking instability, the alarm has been been disabled, so slow drifts of the NMR signal may be missed.

Current Status

Current RC: Dave Gaskell

Future plans

  • Production! Need ~16 hours of high efficiency running to get full statistics

Current Run Plan

  • Continue Q2=3.85, W=3.07, low epsilon data taking on LH2. Switch to dummy on owl shift?
    • SHMS settings: theta = 5.50 degrees, P=6.538 GeV
    • HMS settings: theta = 35.12 degree, P=-1.332 GeV
    • Targets = LH2, dummy, LD2

Notices in Effect for Shift Crew

  • The Raster Coil pair Ax and Ay are off. Raster needs to be at 4x4. Raster gui has been updated - can now request 2x2.
  • With LHe alarms it is good to check the cameras for plumes. If no plume and it is below the LO alarm and above LOLO then monitor with a plot and halog the problem.
  • With LNitrogen alarms are not that critical. Just need to start monitoring the problem with plot and Halog.
  • HMS NMR is not locking stably - the alarm is turned off. Please check on the NMR readback (while it is locked) intermittently to make sure the HMS dipole field is not drifting,

Current Issues

  • Vertical beam position on target has changed a little: Dave Meekins is not concerned about an offset of this size (<0.5 mm).
  • There is a rotation issue that has come up if moving HMS between 19 to 25 degrees. It usually gets stuck around this range, please be wary of this issue. We will likely skip settings in this range if this drive controller error cannot be solved. For singles it will not be a big deal to skip settings for HMS at those angles. We need a longer access to address this issue.
  • The Raster Coil pair Ax and Ay are off
  • Diffuser limit at 46uA (Note: is this still valid?)


Crew Chiefs, We have permission to raise the Hall C diffuser raster limit to allow running >46uA to Hall C. This limit is normally imposed when one of the two rasters is not operative. Since the hall was able to double the running raster current to get the same size raster on the target as having both rasters, Keith is allowing us to raise the limit. To get to the setting, open the Hall C diffuser interlocks screen. Go to the bottom right corner and open the Expert screen. Just below and to the right of the FSD bits, raise the "Raster 1 OK Limit" to slightly above the highest current the hall wants to run at. Do not change the Raster 2 limit. Make a log entry with screen shots. Make an ABIL entry, System MPS and an expected removal date of 3 Jan. 2022. Paul

Planned Accesses to the Hall

  • None

Planned Accelerator Configuration Changes

  • None

Special Requests

  • None