Difference between revisions of "Spring 2018 Commissioning"

From HallCWiki
Jump to navigationJump to search
Line 24: Line 24:
  
 
= DAQ/Trigger Run Plans =
 
= DAQ/Trigger Run Plans =
 +
 +
== Single Arm & Coincidence Dead Time Studies ==
 +
 +
=== Run Conditions ===
 +
 +
*  Kinematics that provide ~1.5 kHz at 1-5 uA in each spectrometer arm and coincidence mode
 +
* These runs can be performed parasitically
 +
 +
=== Run Plans ===
 +
 +
* Single arm runs
 +
# 5 uA, ~1.5 kHz, EDTM off, ~10 min (1 mil events)
 +
# 5 uA, ~1.5 kHz, EDTM off, ~10 min (1 mil events)
  
 
== SHMS & HMS Mode 10 Runs ==
 
== SHMS & HMS Mode 10 Runs ==
 +
 +
=== Run Conditions ===
 +
 +
* At 1.5 kHz these runs should take ~1 min
 +
* These runs can be performed parasitically
 +
 +
=== Run Plans ===
  
 
* SHMS Runs
 
* SHMS Runs
Line 35: Line 55:
  
 
== Single Arm and Coincidence EDTM Studies ==
 
== Single Arm and Coincidence EDTM Studies ==
 +
 +
=== Run Conditions ===
 +
 +
* EDTM 10 Hz runs should be taken when the run lengths are > 30 minutes
 +
* EDTM 100 Hz runs should be taken when the run lengths are < 30 minutes
 +
* If short runs are being performed then the EDTM can be run at 1 kHz
 +
* These runs can be performed parasitically although folks will need to know how to cut the EDTM events out of the data
 +
 +
=== Run Plans ===
  
 
* SHMS Single arm EDTM runs at various rates
 
* SHMS Single arm EDTM runs at various rates
Line 47: Line 76:
  
 
== Trigger PID Threshold Scans ==
 
== Trigger PID Threshold Scans ==
 +
 +
=== Run Conditions ===
 +
 +
* Runs should contain ~500k events which at 1.5 kHz trigger rate will take 5 minutes per run
 +
* These runs can be performed parasitically
 +
 +
=== Run Plans ===
  
 
* SHMS PID threshold scan with NGC in trigger (HGC was previously utilized)
 
* SHMS PID threshold scan with NGC in trigger (HGC was previously utilized)
Line 57: Line 93:
  
 
* HMS PID threshold scan
 
* HMS PID threshold scan
# CER 40, PRSH-LO 40, PRSH-HI 60, SH-LO 40 ---> These are the initial settings
+
# CER 40, PRSH-LO 40, PRSH-HI 60, SH-LO 40
 
# CER 30, PRSH-LO 30, PRSH-HI 50, SH-LO 30
 
# CER 30, PRSH-LO 30, PRSH-HI 50, SH-LO 30
 
# CER 25, PRSH-LO 25, PRSH-HI 40, SH-LO 25
 
# CER 25, PRSH-LO 25, PRSH-HI 40, SH-LO 25
Line 65: Line 101:
  
 
== Single arm SHMS & HMS runs with EL-REAL and EL-CLEAN being readout (need to time these in at the TI front panel) ==
 
== Single arm SHMS & HMS runs with EL-REAL and EL-CLEAN being readout (need to time these in at the TI front panel) ==
 +
 +
=== Run Conditions ===
 +
 +
* Runs should contain ~500k events which at 1.5 kHz trigger rate will take 5 minutes per run
 +
* These runs can be performed parasitically
 +
 +
=== Run Plans ===
  
 
* SHMS single arm multi-trigger type studies
 
* SHMS single arm multi-trigger type studies

Revision as of 10:21, 9 January 2018

Overview

Topics which are relevant to the DAQ/Trigger for the Spring 2018 commissioning run are discussed here.

To-Do

  • High Priority
    • Configure Dave G. Dead time measurement scheme (Arrington’s and/or Morhings thesis)
    • Configure NGC into SHMS PID trigger leg in place of HGC
    • Sanity check SHMS hodoscope CAMAC power supply (noticed unstable behavior during end of fall run)
    • Add SHMS PRSHWRSUM in trigger apparatus (FADC leaf)
    • Remove layer B from HMS pre-shower sum
  • Medium Priority
    • Figure out DAC to mV conversion factor, find old talk regarding setting the DAC values to obtain pedestals a pre-determined value
    • Include multi-hit capability in the trigger apparatus for reference times
    • Integrate TI scalers into report files
    • Configure OR of hodoscope trigger logic into TDC’s and scalers
    • Change trigger leaf names to PRLO from PRSHWRLO etc. (needs to match xscaler)
  • Low Priority
    • Add number of FADC error flags to the report files (front and center)
    • Add number of pulses identified in the window to data tree

DAQ/Trigger Run Plans

Single Arm & Coincidence Dead Time Studies

Run Conditions

  • Kinematics that provide ~1.5 kHz at 1-5 uA in each spectrometer arm and coincidence mode
  • These runs can be performed parasitically

Run Plans

  • Single arm runs
  1. 5 uA, ~1.5 kHz, EDTM off, ~10 min (1 mil events)
  2. 5 uA, ~1.5 kHz, EDTM off, ~10 min (1 mil events)

SHMS & HMS Mode 10 Runs

Run Conditions

  • At 1.5 kHz these runs should take ~1 min
  • These runs can be performed parasitically

Run Plans

  • SHMS Runs
Any kinematics, 100k events
Any kinematics, 100k events, EDTM on at 100 Hz
  • HMS Runs
Any kinematics, 100k events
Any kinematics, 100k events, EDTM on at 100 Hz

Single Arm and Coincidence EDTM Studies

Run Conditions

  • EDTM 10 Hz runs should be taken when the run lengths are > 30 minutes
  • EDTM 100 Hz runs should be taken when the run lengths are < 30 minutes
  • If short runs are being performed then the EDTM can be run at 1 kHz
  • These runs can be performed parasitically although folks will need to know how to cut the EDTM events out of the data

Run Plans

  • SHMS Single arm EDTM runs at various rates
  1. SHMS Run: Any kinematics, EDTM at 10 Hz
  2. SHMS Run: Any kinematics, EDTM at 100 Hz
  • HMS Single arm EDTM runs at various rates
  1. HMS Run: Any kinematics, EDTM at 10 Hz
  2. HMS Run: Any kinematics, EDTM at 100 Hz
  • Coincidence EDTM runs at various rates
  1. Coincidence Run: Any kinematics, EDTM at 10 Hz
  2. Coincidence Run: Any kinematics, EDTM at 100 Hz

Trigger PID Threshold Scans

Run Conditions

  • Runs should contain ~500k events which at 1.5 kHz trigger rate will take 5 minutes per run
  • These runs can be performed parasitically

Run Plans

  • SHMS PID threshold scan with NGC in trigger (HGC was previously utilized)
  1. NGCER 40, PRSH-LO 40, PRSH-HI 60
  2. NGCER 30, PRSH-LO 30, PRSH-HI 50
  3. NGCER 25, PRSH-LO 25, PRSH-HI 40
  4. NGCER 20, PRSH-LO 20, PRSH-HI 30
  5. NGCER 15, PRSH-LO 15, PRSH-HI 20
  6. NGCER 10, PRSH-LO 10, PRSH-HI 10
  • HMS PID threshold scan
  1. CER 40, PRSH-LO 40, PRSH-HI 60, SH-LO 40
  2. CER 30, PRSH-LO 30, PRSH-HI 50, SH-LO 30
  3. CER 25, PRSH-LO 25, PRSH-HI 40, SH-LO 25
  4. CER 20, PRSH-LO 20, PRSH-HI 30, SH-LO 20
  5. CER 15, PRSH-LO 15, PRSH-HI 20, SH-LO 15
  6. CER 10, PRSH-LO 10, PRSH-HI 10, SH-LO 10

Single arm SHMS & HMS runs with EL-REAL and EL-CLEAN being readout (need to time these in at the TI front panel)

Run Conditions

  • Runs should contain ~500k events which at 1.5 kHz trigger rate will take 5 minutes per run
  • These runs can be performed parasitically

Run Plans

  • SHMS single arm multi-trigger type studies
  1. Any kinematics, 500k events, EDTM off
  2. Any kinematics, 500k events, EDTM on at 10 Hz
  • HMS single arm multi-trigger type studies
  1. Any kinematics, 500k events, EDTM off
  2. Any kinematics, 500k events, EDTM on at 10 Hz

Talks