Difference between revisions of "Monitoring/Analysis Instructions During A Shift"

From HallCWiki
Jump to navigationJump to search
Line 5: Line 5:
 
Overview:  
 
Overview:  
 
  The plan is to take SHMS singles, so set the HMS/SHMS angle  
 
  The plan is to take SHMS singles, so set the HMS/SHMS angle  
  and momentum settings in the Run Sheet provided or
+
  and momentum settings in the  
  [https://hallcweb.jlab.org/wiki/images/c/c9/E12_10_003_RunSheetV2.pdf  here.]
+
  [https://hallcweb.jlab.org/wiki/images/c/c9/E12_10_003_RunSheetV2.pdf  Kinematics Sheet]
 
2. In the middle of the run, check online plots for the detectors  
 
2. In the middle of the run, check online plots for the detectors  
  

Revision as of 17:12, 30 March 2018

Instructions for D(e,e'p)n Experiment (E12-10-003)


H(e,e'p) Check and Aluminum Dummy Instructions

Overview:

The plan is to take SHMS singles, so set the HMS/SHMS angle 
and momentum settings in the 
Kinematics Sheet

2. In the middle of the run, check online plots for the detectors

  Login to cdaql1 machine and go to hallc_replay directory:
  > ssh cdaql1 
  > go_analysis 
  for SHMS detector check: ./run_coin_shms.sh <run_number>
  for HMS detector check: ./run_coin_hms.sh <run_number>



3. After full run, check the Good events and Update the file on Google docs

a. Login to cdaql1 machine
b. Update the file " standard.Kinematics " : usually opened in HIGH VOLTAGE Monitor (HCDESK 2 )

  path : 
/net/cdaqfs/home/cdaq/hallc-online/hallc_replay/DBASE/COIN/STD/standard.kinematics
c. Analyze the run with :