Difference between revisions of "Charge Feedback Parity DAQ"

From HallCWiki
Jump to navigationJump to search
(Created page with "The Charge Asymmetry Feedback system is controlled by the Hall A Parity DAQ. When Hall A is in production mode, the Hall A shift crew will manage the Parity DAQ and control f...")
 
 
(22 intermediate revisions by 3 users not shown)
Line 4: Line 4:
  
 
If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running.
 
If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running.
 +
 +
*; This '''must''' be running for all 3He production data!  (And should be running in general.)
 +
** The state of this system is monitored in the Hall C alarm handler, and can be overseen by the Hall C Shift crew using the stripchart on the left large wall display (see below).
 +
[[Image:qasym.jpg|400px|Qasym Stripcharts]]
  
 
== Instructions ==
 
== Instructions ==
 
*; [https://logbooks.jlab.org/entry/3819509 Parity DAQ Running - with Hall C Feedback passively running] (Aug 02, 2020 HClog entry)
 
*; [https://logbooks.jlab.org/entry/3819509 Parity DAQ Running - with Hall C Feedback passively running] (Aug 02, 2020 HClog entry)
 
** Bring up this vnc session using <code>go_parity_feedback</code> under the cdaq account.
 
** Bring up this vnc session using <code>go_parity_feedback</code> under the cdaq account.
[[Image:parity-daq1.jpg|600px|System running under VNC session from Aug 2020]]
+
[[Image:parity-daq1.jpg|400px|System running under VNC session from Aug 2020]]
  
 
*; [https://logbooks.jlab.org/entry/3782536 Hall C running parity DAQ for charge feedback]  (Feb 12, 2020 HCLog entry) -- OLD, just for reference.
 
*; [https://logbooks.jlab.org/entry/3782536 Hall C running parity DAQ for charge feedback]  (Feb 12, 2020 HCLog entry) -- OLD, just for reference.
[[Image:parity-daq2.jpg|600px|System run via ssh tunneling in Feb 2020]]
+
[[Image:parity-daq2.jpg|400px|System run via ssh tunneling in Feb 2020]]
 +
 
 +
=== Useful Commands (on cdaq machines) ===
 +
* <code>go_parity</code>  Injector parity settings (IHWP status, Hall Laser IA settings, etc)
 +
* <code>go_parity_feedback</code> Bring up the Parity DAQ charge feedback VNC session (if Hall C is running alone; see below)
 +
* <code>go_Qasym_stripchart</code> Bring up the Hall C Charge Asym monitoring stripcharts (these should always be up on the big wall screens)
 +
 
 +
=== Procedure to run the flipper script (from the Hall A VNC session) ===
 +
*This script needs to be run when the IHWP state changes and Hall A is not controlling our feedback.
 +
*Call Hall B at least 30 minutes before flipping to give them a heads up.
 +
*When ready to flip:
 +
**'''stop the CODA run''' for the parity DAQ (VNC open on HCDesk2 workspace 2).
 +
**Then call Hall B again to let them know the flip is about to start.
 +
**Then call MCC and ask them to flip the IHWP.
 +
*Confirm the IHWP has been flipped.
 +
* <code> Open (or locate) a terminal in the VNC session from above (VNC open on HCDesk2 workspace 2).  It should be running as apar@adaq2</code>.
 +
* <code> cd ~/feedback2019</code>
 +
* <code> ./FlipPCvaluesHallC</code> You should see the hallc_IACell_setting variable change on the wall
 +
* <code> ./checkPCvaules</code>
 +
*'''start a run''' (parity daq)
 +
* Make an HCLOG entry
 +
 
  
 +
* Log entry with some extra information on restarting the processes if the IA Cell stops updating: https://logbooks.jlab.org/entry/3852609
  
 
== Contacts ==
 
== Contacts ==

Latest revision as of 05:00, 21 September 2020

The Charge Asymmetry Feedback system is controlled by the Hall A Parity DAQ.

When Hall A is in production mode, the Hall A shift crew will manage the Parity DAQ and control feedback for both Hall A and Hall C beams.

If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running.

  • This must be running for all 3He production data! (And should be running in general.)
    • The state of this system is monitored in the Hall C alarm handler, and can be overseen by the Hall C Shift crew using the stripchart on the left large wall display (see below).

Qasym Stripcharts

Instructions

System running under VNC session from Aug 2020

System run via ssh tunneling in Feb 2020

Useful Commands (on cdaq machines)

  • go_parity Injector parity settings (IHWP status, Hall Laser IA settings, etc)
  • go_parity_feedback Bring up the Parity DAQ charge feedback VNC session (if Hall C is running alone; see below)
  • go_Qasym_stripchart Bring up the Hall C Charge Asym monitoring stripcharts (these should always be up on the big wall screens)

Procedure to run the flipper script (from the Hall A VNC session)

  • This script needs to be run when the IHWP state changes and Hall A is not controlling our feedback.
  • Call Hall B at least 30 minutes before flipping to give them a heads up.
  • When ready to flip:
    • stop the CODA run for the parity DAQ (VNC open on HCDesk2 workspace 2).
    • Then call Hall B again to let them know the flip is about to start.
    • Then call MCC and ask them to flip the IHWP.
  • Confirm the IHWP has been flipped.
  • Open (or locate) a terminal in the VNC session from above (VNC open on HCDesk2 workspace 2). It should be running as apar@adaq2.
  • cd ~/feedback2019
  • ./FlipPCvaluesHallC You should see the hallc_IACell_setting variable change on the wall
  • ./checkPCvaules
  • start a run (parity daq)
  • Make an HCLOG entry


Contacts

  • Bill Henry (Hall C)
  • Cameron Clarke (Hall A)
  • Caryn Palatchi (Hall A)