Although I expected the physics rate to double between LiD and He2D (since we doubled the number of accepted deuterons), the difference in the total rate seems weird.
 
  
 
=Cross Section Checks=
 
=Cross Section Checks=
  
To look into the matter, I started looking at the cross sections and the luminosity*cross sections to see how different Li was from HeD
+
I also looked at the cross sections and the luminosity*cross sections to see how different Li was from HeD
  
 
[[Image:2014-03-21-cs-check.png|700px]]
 
[[Image:2014-03-21-cs-check.png|700px]]
Line 26: Line 24:
 
! SHMS low x !! SHMS mid x !! SHMS high x !! HMS
 
! SHMS low x !! SHMS mid x !! SHMS high x !! HMS
 
|-
 
|-
| [[Image:2014-03-21-cs-check-shms1.png|300px]] || [[Image:2014-03-21-cs-check-shms2.png|300px]] || [[Image:2014-03-21-cs-check-shms3.png|300px]] || [[Image:2014-03-21-cs-check-hms.png|300px]]
+
| [[Image:2014-03-21-cs-check-shms1.png|400px]] || [[Image:2014-03-21-cs-check-shms2.png|400px]] || [[Image:2014-03-21-cs-check-shms3.png|400px]] || [[Image:2014-03-21-cs-check-hms.png|400px]]
 
|}
 
|}
 +
 +
For each piece (with the possible exception of the SHMS mid x point), the Li dominates slightly over the HeD, which would cause the LiD rates to come out slightly higher than the HeD rates, but it's nearly negligible.
 +
 +
=Conclusion=
 +
 +
If we assume that everything that occurs during the experiment is identical except for target material, then LiD looks like it would be better suited for the b1 measurement if we could consider the Li as tightly-bound HeD, such that LiD --> HeDD. If that's a bad assumption (and everything else is the same), then we can do a better measurement with ND3.

Latest revision as of 09:05, 24 March 2014

LiD

I added LiD into my b1 rates calculations, since from the workshop it sounded like it might be a viable alternative for achieving higher polarization than ND3. Below are the results of ND3, LiD, and LiD-as-He2D (since lithium could be thought of as a tightly bound 4He & deuteron) in the calculations. Each calculation assumes identical target geometry (beads & packing fraction), Pzz, and detector acceptance with the only difference being the material itself.

ND3
2014-03-21-ND3-b1.png
LiD
2014-03-21-LiD-b1.png
He2D
2014-03-21-He2D-b1.png

Cross Section Checks

I also looked at the cross sections and the luminosity*cross sections to see how different Li was from HeD

2014-03-21-cs-check.png

By Spectrometer

Since it's a little difficult to tell exactly where Li and HeD we overlapping for which spectrometer, I broke it down into each:

SHMS low x SHMS mid x SHMS high x HMS
2014-03-21-cs-check-shms1.png 2014-03-21-cs-check-shms2.png 2014-03-21-cs-check-shms3.png 2014-03-21-cs-check-hms.png

For each piece (with the possible exception of the SHMS mid x point), the Li dominates slightly over the HeD, which would cause the LiD rates to come out slightly higher than the HeD rates, but it's nearly negligible.

Conclusion

If we assume that everything that occurs during the experiment is identical except for target material, then LiD looks like it would be better suited for the b1 measurement if we could consider the Li as tightly-bound HeD, such that LiD --> HeDD. If that's a bad assumption (and everything else is the same), then we can do a better measurement with ND3.