Difference between revisions of "J/psi-007 Instructions for Shift Takers"

From HallCWiki
Jump to navigationJump to search
(Created page with "=='''Instructions for J/ψ-007'''== ------------------------------------------------ 1. Keep an eye on the Hall C Scaler Data GUI and make sure the rates with beam ON are s...")
 
Line 12: Line 12:
 
   
 
   
 
For COIN runs, this is:
 
For COIN runs, this is:
$HOME/hallc-online/hallc_replay/DBASE/COIN/standard.kinematics
+
    $HOME/hallc-online/hallc_replay/DBASE/COIN/standard.kinematics
  
 
For runs taken with the separate DAQs during detector checkout and calibrations, the paths are
 
For runs taken with the separate DAQs during detector checkout and calibrations, the paths are
$HOME/hallc-online/hallc_replay/DBASE/HMS/standard.kinematics
+
    $HOME/hallc-online/hallc_replay/DBASE/HMS/standard.kinematics
$HOME/hallc-online/hallc_replay/DBASE/SHMS/standard.kinematics
+
    $HOME/hallc-online/hallc_replay/DBASE/SHMS/standard.kinematics
  
 
See the [[Run plan for J/psi-007|run plan]] to check which DAQ should be running.
 
See the [[Run plan for J/psi-007|run plan]] to check which DAQ should be running.

Revision as of 07:31, 8 February 2019

Instructions for J/ψ-007


1. Keep an eye on the Hall C Scaler Data GUI and make sure the rates with beam ON are steady

2. In the middle of the run, check online plots for the detectors

a. Login to cdaql1 machine and go to hallc_replay directory if you are not there already:

  > ssh cdaql1 
  > go_analysis 

b. Update the file " standard.Kinematics ":

For COIN runs, this is:

   $HOME/hallc-online/hallc_replay/DBASE/COIN/standard.kinematics

For runs taken with the separate DAQs during detector checkout and calibrations, the paths are

   $HOME/hallc-online/hallc_replay/DBASE/HMS/standard.kinematics
   $HOME/hallc-online/hallc_replay/DBASE/SHMS/standard.kinematics

See the run plan to check which DAQ should be running.

c. At 50k events, run scripts

  for SHMS detector check: ./run_coin_shms.sh <run_number>
  for HMS detector check: ./run_coin_hms.sh <run_number>

Note electron tracking efficiency for HMS and hadron tracking efficiency for SHMS from resulting report files.