Difference between revisions of "J/psi-007 Instructions for Shift Takers"

From HallCWiki
Jump to navigationJump to search
Line 5: Line 5:
 
1. Keep an eye on the Hall C Scaler Data GUI and make sure the rates with beam ON are steady
 
1. Keep an eye on the Hall C Scaler Data GUI and make sure the rates with beam ON are steady
  
2. In the middle of the run, check online plots for the detectors  
+
2. After 50K triggers, check online plots for the detectors  
  
 
a. Login to cdaql1 machine and go to hallc_replay directory if you are not there already:
 
a. Login to cdaql1 machine and go to hallc_replay directory if you are not there already:
Line 22: Line 22:
 
See the [[Run plan for J/psi-007|run plan]] to check which DAQ should be running.
 
See the [[Run plan for J/psi-007|run plan]] to check which DAQ should be running.
  
c. At 50k events, run scripts
+
c. WHen running coin DAQ, at 50k events, run scripts
  
 
   for SHMS detector check: ./run_coin_shms.sh <run_number>
 
   for SHMS detector check: ./run_coin_shms.sh <run_number>
  
 
   for HMS detector check: ./run_coin_hms.sh <run_number>
 
   for HMS detector check: ./run_coin_hms.sh <run_number>
 +
c. WHen running two single arm DAQs, at 50k events, run scripts
 +
 +
  for SHMS detector check: ./run_shms.sh <run_number>
 +
 +
  for HMS detector check: ./run_hms.sh <run_number>
  
 
Note electron tracking efficiency for HMS and hadron tracking efficiency for SHMS from resulting report files.
 
Note electron tracking efficiency for HMS and hadron tracking efficiency for SHMS from resulting report files.

Revision as of 08:47, 9 February 2019

Main | Online | RC | Run Plan | Official Website | Redmine | Index | Nav
Jpsi007.png

Instructions for J/ψ-007


1. Keep an eye on the Hall C Scaler Data GUI and make sure the rates with beam ON are steady

2. After 50K triggers, check online plots for the detectors

a. Login to cdaql1 machine and go to hallc_replay directory if you are not there already:

  > ssh cdaql1 
  > go_analysis 

b. Update the file " standard.Kinematics ":

For COIN runs, this is:

   $HOME/hallc-online/hallc_replay/DBASE/COIN/standard.kinematics

For runs taken with the separate DAQs during detector checkout and calibrations, the paths are

   $HOME/hallc-online/hallc_replay/DBASE/HMS/standard.kinematics
   $HOME/hallc-online/hallc_replay/DBASE/SHMS/standard.kinematics

See the run plan to check which DAQ should be running.

c. WHen running coin DAQ, at 50k events, run scripts

  for SHMS detector check: ./run_coin_shms.sh <run_number>
  for HMS detector check: ./run_coin_hms.sh <run_number>

c. WHen running two single arm DAQs, at 50k events, run scripts

  for SHMS detector check: ./run_shms.sh <run_number>
  for HMS detector check: ./run_hms.sh <run_number>

Note electron tracking efficiency for HMS and hadron tracking efficiency for SHMS from resulting report files.