To reset the hall C target motion, several devices need to be rebooted.

WARNING: After iochc26 boots up, the target will home itself, so you need to mask the FSD first!!

First, use hcreboot5 to turn off the iochc26 VME crate (outlet 2).

Next, use hcreboot6 to reboot portservhc26 (outlet 1) and the VXM-1 Motor controller (outlet 2)

Finally, use hcreboot5 to turn iochc26 (outlet 2 again) back on.