Jump to navigationJump to search (Created page with "The Charge Asymmetry Feedback system is controlled by the Hall A Parity DAQ. When Hall A is in production mode, the Hall A shift crew will manage the Parity DAQ and control f...") |
|||
Line 4: | Line 4: | ||
If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running. | If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running. | ||
+ | |||
+ | *; This '''must''' be running for all 3He production data! (And should be running in general.) | ||
+ | ** The state of this system is monitored in the Hall C alarm handler, and can be overseen by the Hall C Shift crew using the stripchart on the left large wall display (see below). | ||
+ | [[Image:qasym.jpg|400px|Qasym Stripcharts]] | ||
== Instructions == | == Instructions == | ||
*; [https://logbooks.jlab.org/entry/3819509 Parity DAQ Running - with Hall C Feedback passively running] (Aug 02, 2020 HClog entry) | *; [https://logbooks.jlab.org/entry/3819509 Parity DAQ Running - with Hall C Feedback passively running] (Aug 02, 2020 HClog entry) | ||
** Bring up this vnc session using <code>go_parity_feedback</code> under the cdaq account. | ** Bring up this vnc session using <code>go_parity_feedback</code> under the cdaq account. | ||
− | [[Image:parity-daq1.jpg| | + | [[Image:parity-daq1.jpg|400px|System running under VNC session from Aug 2020]] |
*; [https://logbooks.jlab.org/entry/3782536 Hall C running parity DAQ for charge feedback] (Feb 12, 2020 HCLog entry) -- OLD, just for reference. | *; [https://logbooks.jlab.org/entry/3782536 Hall C running parity DAQ for charge feedback] (Feb 12, 2020 HCLog entry) -- OLD, just for reference. | ||
− | [[Image:parity-daq2.jpg| | + | [[Image:parity-daq2.jpg|400px|System run via ssh tunneling in Feb 2020]] |
+ | |||
+ | === Useful Commands === | ||
+ | * <code>go_parity</code> Injector parity settings (IHWP status, Hall Laser IA settings, etc) | ||
+ | * <code>go_parity_feedback</code> Bring up the Parity DAQ charge feedback VNC session (if Hall C is running alone; see below) | ||
+ | * <code>go_Qasym_stripchart</code> Bring up the Hall C Charge Asym monitoring stripcharts (these should always be up on the big wall screens) | ||
Revision as of 15:53, 2 August 2020
The Charge Asymmetry Feedback system is controlled by the Hall A Parity DAQ.
When Hall A is in production mode, the Hall A shift crew will manage the Parity DAQ and control feedback for both Hall A and Hall C beams.
If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running.
- This must be running for all 3He production data! (And should be running in general.)
- The state of this system is monitored in the Hall C alarm handler, and can be overseen by the Hall C Shift crew using the stripchart on the left large wall display (see below).
Instructions
- Parity DAQ Running - with Hall C Feedback passively running (Aug 02, 2020 HClog entry)
- Bring up this vnc session using
go_parity_feedback
under the cdaq account.
- Hall C running parity DAQ for charge feedback (Feb 12, 2020 HCLog entry) -- OLD, just for reference.
Useful Commands
go_parity
Injector parity settings (IHWP status, Hall Laser IA settings, etc)go_parity_feedback
Bring up the Parity DAQ charge feedback VNC session (if Hall C is running alone; see below)go_Qasym_stripchart
Bring up the Hall C Charge Asym monitoring stripcharts (these should always be up on the big wall screens)