Difference between revisions of "Taking Cosmic Data"
From HallCWiki
Jump to navigationJump to search (Created page with "=Load the NPS HV for cosmic run= * Follow the instruction of "Setting new NPS Calorimeter HV values" to load the HVs for cosmic run: https://hallcweb.jlab.org/wiki/index.php/N...") |
|||
Line 1: | Line 1: | ||
=Load the NPS HV for cosmic run= | =Load the NPS HV for cosmic run= | ||
− | * Follow the instruction | + | * Follow the instruction in the section: "Setting new NPS Calorimeter HV values" to load the HVs for cosmic run: https://hallcweb.jlab.org/wiki/index.php/NPS_Calo_SlowControls |
* Make a logentry after changing the HVs | * Make a logentry after changing the HVs | ||
Revision as of 16:38, 6 December 2023
Load the NPS HV for cosmic run
- Follow the instruction in the section: "Setting new NPS Calorimeter HV values" to load the HVs for cosmic run: https://hallcweb.jlab.org/wiki/index.php/NPS_Calo_SlowControls
- Make a logentry after changing the HVs
Turn on the sintillators
- The sintillators for cosmic trigger are 30-00 and 30-08 with the following setting: Vmax=1600, Vset=1590, Imax=650.
Take cosmic data with Coin Daq Cosmic Configuration
- Follow the daq instructions here: https://hallcweb.jlab.org/wiki/index.php/Hall_C_DAQ#If_the_CODA_vnc_session_disappeared_and_.27go_coin_daq.27_doesn.27t_work
- Start the daq in Coin mode following the instructions above
- In the Run Control GUI select the coda configuration "coin_cosmic"
- Start a run with ps2=0