Difference between revisions of "F2/XEM Mar 2, 2018 9:00am"

From HallCWiki
Jump to navigationJump to search
m
Line 2: Line 2:
  
 
== Minutes ==
 
== Minutes ==
 +
 +
*Fernando: Looked into the adc time cuts. [https://hallcweb.jlab.org/elogs/E12-10-002+Preparations/90]
 +
 +
check low momentum run and apply calibration param from the run to higher momentum run. Check pr vs sh correlation for different momenta.
 +
 +
*Abishek: SHMS DC calibration result was shown. [https://hallcweb.jlab.org/elogs/E12-10-002+Preparations/91]
 +
 +
Post residual too. Send the calibration file to Abel.
 +
For HMS, still needs to shift drift time manually for some wires. Check fit quality.
 +
 +
*Abel: Data vs MC comparison. Applied new calorimeter calibration from Fernando, but didn't see much of difference. 
 +
Wait for Mark to look at the SHMS optics.
 +
 +
*Simona: HMS Cer calibration. [https://hallcweb.jlab.org/elogs/E12-10-002+Preparations/92] Still see inefficiency at delta < -6  and bump around 1.5. PMT1 (top) covers negative delta, npe drops at dp < -6 to around 1 (probably the ones below FADC threshold).
 +
We could just put a analysis cut or change (lower) FADC threshold. If we do change the threshold: check data and log run# when change was made.
 +
 +
 +
*F2/XEM git repository: forked from hallc_replay [https://github.com/hallc-f2xem/hallc_replay]
 +
 +
*Run plan: Polarity change after finishing up 33 deg (probably on Sunday).
 +
 +
*Special task plan: boiling study and BCM calibration.
 +
 +
*Dave will discuss with Eric for setting up group disk on ifarm.

Revision as of 10:34, 2 March 2018

Back to DailyMeeting

Minutes

  • Fernando: Looked into the adc time cuts. [1]

check low momentum run and apply calibration param from the run to higher momentum run. Check pr vs sh correlation for different momenta.

  • Abishek: SHMS DC calibration result was shown. [2]

Post residual too. Send the calibration file to Abel. For HMS, still needs to shift drift time manually for some wires. Check fit quality.

  • Abel: Data vs MC comparison. Applied new calorimeter calibration from Fernando, but didn't see much of difference.

Wait for Mark to look at the SHMS optics.

  • Simona: HMS Cer calibration. [3] Still see inefficiency at delta < -6 and bump around 1.5. PMT1 (top) covers negative delta, npe drops at dp < -6 to around 1 (probably the ones below FADC threshold).

We could just put a analysis cut or change (lower) FADC threshold. If we do change the threshold: check data and log run# when change was made.


  • F2/XEM git repository: forked from hallc_replay [4]
  • Run plan: Polarity change after finishing up 33 deg (probably on Sunday).
  • Special task plan: boiling study and BCM calibration.
  • Dave will discuss with Eric for setting up group disk on ifarm.