D(e,e'p)n Experiment (E12-10-003) Data Run Sheet
+
*[https://docs.google.com/spreadsheets/d/1POJV6RpUhEnjKHxZRPo0Y_z7sntbdPJeq7AUjSbZDbU/edit#gid=0D(e,e'p)n Experiment (E12-10-003) Data Run Sheet]
 
==April 2018==
 
==April 2018==
 
===Friday 13===
 
===Friday 13===

Revision as of 10:10, 13 April 2018

April 2018

Friday 13

  • Looked at reference time plots for hodoscopes/drift chambers TDCs/ADCs to determine if the reference time cuts set in the parameter file are OK (not cutting real triggers or real accidentals). I looked at 50k events for coincidence run 3267, (80 MeV setting) *See Plots I modified the parameter files accordingly, to include the real physics triggers. The parameter files to adjust the reference time cuts are in:
    • PARAM/HMS/GEN/h_reftime_cut.param
    • PARAM/SHMS/GEN/p_reftime_cut.param