Line 35: Line 35:
 
|BPM calibration check || Not done || Need to have 7A harp operational, during Friday down will be looked at
 
|BPM calibration check || Not done || Need to have 7A harp operational, during Friday down will be looked at
 
|-
 
|-
|Beam energy measurement || Not done ||
+
|Beam energy measurement || Completed [https://logbooks.jlab.org/entry/3604093] ||
 
|-
 
|-
 
|High and low current BCM calibration || Completed low current up to 57uA || [https://logbooks.jlab.org/entry/3602122 Calibration plots]
 
|High and low current BCM calibration || Completed low current up to 57uA || [https://logbooks.jlab.org/entry/3602122 Calibration plots]

Revision as of 15:33, 5 October 2018

  • Table of Kaon LT Physics Status
Item Status Comment
Q2=3.0 W=2.32 x=0.40 theta_Shms=15.18 Completed
Q2=3.0 W=2.32 x=0.40 theta_Shms=18.18 Completed
Q2=3.0 W=2.32 x=0.40 theta_Shms=21.18 Completed Summary plot of all three settings
Q2=2.115 W=2.95 x=0.21 theta_Shms=7.74 Completed ~43 % of min statistical goal [1]
Q2=2.115 W=2.95 x=0.21 theta_Shms=10.74 Completed 43 % of min statistical goal [2]
Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 Completed 43 % of min statistical goal [3]
Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 To do We start here
Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 To do
Q2=4.4 W=2.74 x=0.4 theta_Shms=15.81 To do
  • Table of Kaon LT Commissioning Status.
Item Status Comment
Detector Checkout Completed
HMS Trigger PID Completed
SHMS Trigger PID Completed
BPM calibration check Not done Need to have 7A harp operational, during Friday down will be looked at
Beam energy measurement Completed [4]
High and low current BCM calibration Completed low current up to 57uA Calibration plots
HMS/SHMS optics study Completed
HMS/SHMS single arm elastic Completed
HMS/SHMS coincidence ep elastic Completed 25K events ( wanted 50K)
Golden HMS/SHMS sieve run Completed Used to check the stability of beam positions at different energies
Luminosity scan Not done Need fairly stable 65uA