Difference between revisions of "Kaon LT Status Page"

From HallCWiki
Jump to navigationJump to search
Line 15: Line 15:
 
|Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 || Completed || 43 % of min statistical goal [https://logbooks.jlab.org/entry/3603234]  
 
|Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 || Completed || 43 % of min statistical goal [https://logbooks.jlab.org/entry/3603234]  
 
|-
 
|-
|Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 || Al in progress || 58% of min statistical goal taken on LH2
+
|Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 || 58% of min goal || 58% of min statistical goal taken on LH2; Al done
 
|-
 
|-
|Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 || To do ||  
+
|Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 || Al in progress ||  
 
|-
 
|-
 
|Q2=4.4 W=2.74 x=0.4 theta_Shms=15.81 || To do ||  
 
|Q2=4.4 W=2.74 x=0.4 theta_Shms=15.81 || To do ||  

Revision as of 12:05, 6 October 2018

  • Table of Kaon LT Physics Status
Item Status Comment
Q2=3.0 W=2.32 x=0.40 theta_Shms=15.18 Completed
Q2=3.0 W=2.32 x=0.40 theta_Shms=18.18 Completed
Q2=3.0 W=2.32 x=0.40 theta_Shms=21.18 Completed Summary plot of all three settings
Q2=2.115 W=2.95 x=0.21 theta_Shms=7.74 Completed ~43 % of min statistical goal [1]
Q2=2.115 W=2.95 x=0.21 theta_Shms=10.74 Completed 43 % of min statistical goal [2]
Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 Completed 43 % of min statistical goal [3]
Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 58% of min goal 58% of min statistical goal taken on LH2; Al done
Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 Al in progress
Q2=4.4 W=2.74 x=0.4 theta_Shms=15.81 To do
  • Table of Kaon LT Commissioning Status.
Item Status Comment
Detector Checkout Completed
HMS Trigger PID Completed
SHMS Trigger PID Completed
BPM calibration check Not done
Beam energy measurement Completed [4]
High and low current BCM calibration Completed low current up to 57uA Calibration plots
HMS/SHMS optics study Completed
HMS/SHMS single arm elastic Completed
HMS/SHMS coincidence ep elastic Completed 25K events ( wanted 50K)
Golden HMS/SHMS sieve run Completed Used to check the stability of beam positions at different energies
Luminosity scan Not done Need fairly stable 65uA