= Calibrations =
 
= Calibrations =
== Subsystem 1 ==
+
== Basic Template for each Detector/Calibration Procedure ==
 +
For each detector subsystem we would like to capture/document the following information:
 +
* A list of all (or at least the most useful) ROOT tree variables associated with this detector
 +
* Description of the calibration algorithm (That is, how is it supposed to work -- what is the logic behind it?)
 +
* Files involved in the calibration
 +
** THc* or THa* modules that are needed/used
 +
** Database files that will be modified
 +
** Scripts that will be used
 +
** Dependencies of this calibration
 +
*** Reference time cuts should be verified
 +
*** FADC 'hit selection' timing cuts should be verified
 +
*** Calorimeter calibration relies on good optics calibration for momentum determination
 +
*** If tight timing cuts are used, then the hodoscopes may need to be calibrated first, etc
 +
*** ... etc
 +
* Provide a step-by-step "Howto" that shows
 +
** What commands/scripts need to be run, in what order.
 +
** How do you verify that various cuts (ref times, trigger types, etc) are correct before you run the script(s)?
 +
** What do you look for to verify that the code has run correctly after you run the script(s)?
 +
 
 +
 
 +
== Hodoscopes ==
 +
 
 +
== Calorimeter ==
 +
 
 +
== Gas Cerenkovs ==
 +
 
 +
== Aerogel (?) ==
 +
 
 +
== Optics ==
 +
 
 +
== EDTM ==
 +
 
 +
== ... ==

Revision as of 18:30, 25 September 2019

Pol He-3 Analysis Resources

Calibrations

Basic Template for each Detector/Calibration Procedure

For each detector subsystem we would like to capture/document the following information:

  • A list of all (or at least the most useful) ROOT tree variables associated with this detector
  • Description of the calibration algorithm (That is, how is it supposed to work -- what is the logic behind it?)
  • Files involved in the calibration
    • THc* or THa* modules that are needed/used
    • Database files that will be modified
    • Scripts that will be used
    • Dependencies of this calibration
      • Reference time cuts should be verified
      • FADC 'hit selection' timing cuts should be verified
      • Calorimeter calibration relies on good optics calibration for momentum determination
      • If tight timing cuts are used, then the hodoscopes may need to be calibrated first, etc
      • ... etc
  • Provide a step-by-step "Howto" that shows
    • What commands/scripts need to be run, in what order.
    • How do you verify that various cuts (ref times, trigger types, etc) are correct before you run the script(s)?
    • What do you look for to verify that the code has run correctly after you run the script(s)?


Hodoscopes

Calorimeter

Gas Cerenkovs

Aerogel (?)

Optics

EDTM

...