Difference between revisions of "Drawings of SHMS magnets"
From HallCWiki
Jump to navigationJump to searchLine 3: | Line 3: | ||
*[[https://hallcweb.jlab.org/wiki/images/9/9c/Shms_magnet_field_summary.pdf Summary table ]] of the SHMS magnets field properties. From Steve Lassiter file magnet_summary.doc on Sept 9th 2011. | *[[https://hallcweb.jlab.org/wiki/images/9/9c/Shms_magnet_field_summary.pdf Summary table ]] of the SHMS magnets field properties. From Steve Lassiter file magnet_summary.doc on Sept 9th 2011. | ||
*Horizontal bender magnet dimensions (Mike Fowler on Sept 12th, 2011): [[https://hallcweb.jlab.org/wiki/images/a/a0/Bender_Dimensions_topview.jpg Top view]] , [[https://hallcweb.jlab.org/wiki/images/c/c7/Bender_Dimensions_3d.jpg 3-D view]], a few more views of the H bender from 2010, [[Media:Hb_topview.png|top view]], [[Media:Hb_topview2.png| top view at the smallest spectrometer angle]], [[Media:Hb_frontface.png| front face view]], [[Media:Hb_sideview1.png|side view]], [[Media:Hb_sidesectional.png| side sectional view]], [[Media:Hb_topsectional.png| top sectional view]], [[Media:ScreenShot112.jpg| view of aperture]] | *Horizontal bender magnet dimensions (Mike Fowler on Sept 12th, 2011): [[https://hallcweb.jlab.org/wiki/images/a/a0/Bender_Dimensions_topview.jpg Top view]] , [[https://hallcweb.jlab.org/wiki/images/c/c7/Bender_Dimensions_3d.jpg 3-D view]], a few more views of the H bender from 2010, [[Media:Hb_topview.png|top view]], [[Media:Hb_topview2.png| top view at the smallest spectrometer angle]], [[Media:Hb_frontface.png| front face view]], [[Media:Hb_sideview1.png|side view]], [[Media:Hb_sidesectional.png| side sectional view]], [[Media:Hb_topsectional.png| top sectional view]], [[Media:ScreenShot112.jpg| view of aperture]] | ||
− | + | ||
[[Category:SHMSinfo]] | [[Category:SHMSinfo]] |
Revision as of 13:22, 19 September 2012
- [Side view drawing ] of the SHMS Q3 and Dipole with distances. The far left cross hair in the drawing is the x_hut=y_hut=z_hut=0 point from which the detector positions are measured in the hut. The distance from the dipole center to the "zero" point projected perpendicular to the mechanical center axis of the dipole is 3.65m as shown on an annotated drawing with the calculation. [Plot] of detector distances from the "zero" point. (From Mike Fowler on Sept 12th, 2011)
- [Drawing ] with measurements of the dipole entrance flange. [3d picture ] of the dipole entrance.
- [Summary table ] of the SHMS magnets field properties. From Steve Lassiter file magnet_summary.doc on Sept 9th 2011.
- Horizontal bender magnet dimensions (Mike Fowler on Sept 12th, 2011): [Top view] , [3-D view], a few more views of the H bender from 2010, top view, top view at the smallest spectrometer angle, front face view, side view, side sectional view, top sectional view, view of aperture