Jump to navigationJump to searchLine 19: | Line 19: | ||
6.) Switch from pol to unpol frequently<br> | 6.) Switch from pol to unpol frequently<br> | ||
+ | [[Image:sys_error.png|700px]]<br> | ||
− | |||
Additionally:<br> | Additionally:<br> |
Revision as of 12:30, 29 April 2013
Azz is an asymmetry so take advantage of numerator denominator systematics cancellation:
1.) Measure Np and Nu with same cup same exact material
2.) Use same B-field
3.) Use NMR on both to measure polarization and un-polarization
4.) Let beam heating an off larmor microwave control un-polarization
5.) Keep both cold (~1K)
6.) Switch from pol to unpol frequently
Additionally:
Multiple ways to measure b1, Azz
t20 for elastic or quasi still very accessible