Difference between revisions of "Observables2"
From HallCWiki
Jump to navigationJump to searchLine 13: | Line 13: | ||
− | |||
1.) Measure Np and Nu with same cup same exact material<br> | 1.) Measure Np and Nu with same cup same exact material<br> | ||
2.) Use same B-field<br> | 2.) Use same B-field<br> | ||
Line 21: | Line 20: | ||
6.) Switch from pol to unpol frequently<br> | 6.) Switch from pol to unpol frequently<br> | ||
+ | Reminder:Estimated Systematics<br> | ||
[[Image:sys_error.png|500px]]<br> | [[Image:sys_error.png|500px]]<br> | ||
Revision as of 12:33, 29 April 2013
Azz is an asymmetry so take advantage of numerator denominator systematics cancellation:
1.) Measure Np and Nu with same cup same exact material
2.) Use same B-field
3.) Use NMR on both to measure polarization and un-polarization
4.) Let beam heating an off larmor microwave control un-polarization
5.) Keep both cold (~1K)
6.) Switch from pol to unpol frequently
Reminder:Estimated Systematics
Additionally:
Multiple ways to measure b1, Azz
t20 for elastic or quasi still very accessible