Difference between revisions of "Hall C EDTM Pulser"

From HallCWiki
Jump to navigationJump to search
Line 2: Line 2:
 
== Remotely adjustable EDTM ==
 
== Remotely adjustable EDTM ==
 
Currently set with a a command-line helper <code>go_edtm</code>'''
 
Currently set with a a command-line helper <code>go_edtm</code>'''
* There is a command-line helper <code>go_edtm</code> to set/readback this PV.  (the prescale_GUI xyz does not set it at the moment.)
+
* There is a command-line helper <code>go_edtm</code> to set/readback this PV.  (the prescale_GUI does not set it at the moment.)
 
* More details are in this log entry:  [https://logbooks.jlab.org/entry/3893007 EDTM pulser switched to cdaqpi1 output]
 
* More details are in this log entry:  [https://logbooks.jlab.org/entry/3893007 EDTM pulser switched to cdaqpi1 output]
 
** The RPi that controls this is cdaqpi1 which runs an EPICS softIOC.  Ellen B. or Brad S. should be contacted if that device has an issue.
 
** The RPi that controls this is cdaqpi1 which runs an EPICS softIOC.  Ellen B. or Brad S. should be contacted if that device has an issue.
Line 9: Line 9:
  
 
<noinclude>
 
<noinclude>
 +
 
==<s> Manually settable pulse generator </s> ==
 
==<s> Manually settable pulse generator </s> ==
 
  '''A version of this will be revived by the xem2 experiment for the HMS singles running.  Ask the experts.  We'll post info ASAP.'''
 
  '''A version of this will be revived by the xem2 experiment for the HMS singles running.  Ask the experts.  We'll post info ASAP.'''

Revision as of 15:47, 30 September 2022

Remotely adjustable EDTM

Currently set with a a command-line helper go_edtm

  • There is a command-line helper go_edtm to set/readback this PV. (the prescale_GUI does not set it at the moment.)
  • More details are in this log entry: EDTM pulser switched to cdaqpi1 output
    • The RPi that controls this is cdaqpi1 which runs an EPICS softIOC. Ellen B. or Brad S. should be contacted if that device has an issue.
    • Note, at present this only works for the SHMS DAQ. Therefore it works for SHMS singles or coincidence running. For HMS, contact the expert.



Manually settable pulse generator

A version of this will be revived by the xem2 experiment for the HMS singles running.  Ask the experts.  We'll post info ASAP.

  • If the EDTM pulse generator located in rack CH03B06 is reset for any reason, the settings must be restored to the following parameters as outlined in this logbook entry

EDTM pulser settings.jpg