Difference between revisions of "Hall C DAQ"
Line 1: | Line 1: | ||
= How to kill/reset/restart the DAQ, or, "The DAQ is dead, now what..." = | = How to kill/reset/restart the DAQ, or, "The DAQ is dead, now what..." = | ||
+ | |||
+ | === How to connect to VNC session ==== | ||
+ | |||
+ | ssh into cdaq@cdaql1 and from there type: | ||
+ | go_nps_daq or go_coin_daq (they are the same). | ||
+ | |||
+ | If running HMS-standalone type go_hms_daq | ||
=== If you are connected to the appropriate DAQ vncsession === | === If you are connected to the appropriate DAQ vncsession === | ||
− | If you are connected to the appropriate DAQ vncsession | + | If you are connected to the appropriate DAQ vncsession, and |
CODA has hung, or gotten into a funny state, then bring the terminal window at | CODA has hung, or gotten into a funny state, then bring the terminal window at | ||
− | lower left to the foreground and type the | + | lower left to the foreground and type the appropriate kcoda / startCoda script, |
− | % kcoda | + | which depends on what you are running, which is probably coincidence |
+ | % killCoin for coincidence DAQ, kcoda for NPS-standalone, killHMS for HMS-standalone. | ||
Wait for a bit (10 sec). Then restart coda by typing this in the same terminal: | Wait for a bit (10 sec). Then restart coda by typing this in the same terminal: | ||
− | % | + | % startCoin for coincidence DAQ, startCoda for NPS-standalone, startHMS for HMS-standalone. |
You will then have to complete the 'standard' CODA steps: | You will then have to complete the 'standard' CODA steps: | ||
Line 14: | Line 22: | ||
# Click on the 'Tools' icon. | # Click on the 'Tools' icon. | ||
# Then you should be able to start a run as usual. | # Then you should be able to start a run as usual. | ||
+ | |||
+ | If you the components can't connect, it may be that the platform is not running, so you | ||
+ | can restart it by typing "platform &" on coda@cdaql6. But first check the process list | ||
+ | "ps awx | grep platform" | ||
* ''Make an hclog and document the error you saw (screen snapshot, etc) if you choose to do this.'' | * ''Make an hclog and document the error you saw (screen snapshot, etc) if you choose to do this.'' | ||
Line 25: | Line 37: | ||
− | === If the CODA vnc session disappeared and ' | + | === If the CODA vnc session disappeared and 'go_coin_daq' doesn't work === |
NOTE: Ask a DAQ expert and/or the RC '''before''' you do this. It really should never be needed. | NOTE: Ask a DAQ expert and/or the RC '''before''' you do this. It really should never be needed. | ||
Line 32: | Line 44: | ||
can bring things up from scratch outside the VNC session. | can bring things up from scratch outside the VNC session. | ||
− | ==== | + | ==== COIN Mode ==== |
+ | % ssh coda@cdaql6 | ||
+ | In that terminal, run: | ||
+ | % startCoin | ||
+ | |||
+ | ==== NPS standalone ==== | ||
% ssh coda@cdaql6 | % ssh coda@cdaql6 | ||
In that terminal, run: | In that terminal, run: | ||
− | % | + | % startCoda |
− | ==== HMS ==== | + | ==== HMS standalone ==== |
% ssh coda@cdaql5 | % ssh coda@cdaql5 | ||
In that terminal, run: | In that terminal, run: | ||
− | % | + | % startHMS |
− | |||
− | |||
− | |||
− | |||
− | |||
==== If the Event Builder (EB) process keeps dying when you try to start a run ==== | ==== If the Event Builder (EB) process keeps dying when you try to start a run ==== | ||
Line 57: | Line 69: | ||
as the 'cdaq' user: | as the 'cdaq' user: | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
===== Switching Back to Single Arm DAQs ===== | ===== Switching Back to Single Arm DAQs ===== | ||
Line 120: | Line 93: | ||
==== COIN mode ==== | ==== COIN mode ==== | ||
− | Coincidence (COIN) mode uses ''both'' the ''' | + | Coincidence (COIN) mode uses ''both'' the '''NPS''' and '''HMS''' ROCs, so you will need to reboot '''all''' of them using the links in the two sub-sections below. |
− | After you have power cycled all the ROCs, wait for 2--3 minutes then run ''' | + | After you have power cycled all the ROCs, wait for 2--3 minutes then run '''kcodaCoin'''; and '''startCoin'''. If that doesn't work, call an Expert. |
* ''Make an hclog when you do this!'' | * ''Make an hclog when you do this!'' | ||
− | ==== SHMS ==== | + | ==== SHMS (not used during NPS ==== |
− | + | ||
− | |||
− | |||
− | |||
− | |||
− | |||
Reboot them by clicking on the link, and cycling the power. '''Wait for 10s after clicking the 'power' button ''before'' clicking it again'''. The page will automatically refresh when it is ready. | Reboot them by clicking on the link, and cycling the power. '''Wait for 10s after clicking the 'power' button ''before'' clicking it again'''. The page will automatically refresh when it is ready. | ||
Line 141: | Line 109: | ||
==== HMS ==== | ==== HMS ==== | ||
− | The HMS has three ROCs. | + | The HMS has three ROCs. Follow these links to power-cycle: |
* [http://hccrate01 ROC01] (Counting House Electronics Room) | * [http://hccrate01 ROC01] (Counting House Electronics Room) | ||
* [http://hccrate03 ROC03] (HMS Electronics Hut -- the wire chambers) | * [http://hccrate03 ROC03] (HMS Electronics Hut -- the wire chambers) | ||
* [http://hccrate05 ROC05] (Counting House Electronics Room) --- On APC switch. See note below. | * [http://hccrate05 ROC05] (Counting House Electronics Room) --- On APC switch. See note below. | ||
− | The | + | ==== NPS ==== |
+ | The NPS has five ROCs and five VTPs. The VTPs get power cycled when you cycle the ROCs. | ||
+ | * [http://nps-crate1 npsvme1 and npsvtp1] (NPS crate 1) | ||
+ | * [http://nps-crate2 npsvme2 and npsvtp2] (NPS crate 2) | ||
+ | * [http://nps-crate3 npsvme3 and npsvtp3] (NPS crate 3) | ||
+ | * [http://nps-crate4 npsvme4 and npsvtp4] (NPS crate 4) | ||
+ | * [http://nps-crate5 npsvme5 and npsvtp5] (NPS crate 5) | ||
+ | |||
+ | |||
+ | Reboot them by clicking on the link, and cycling the power. '''Wait for 10s after clicking the 'power' button ''before'' clicking it again'''. The page will automatically refresh when it is ready. | ||
+ | |||
+ | After you have power cycled all the ROCs, wait for 2--3 minutes then run the appropriate script (killCoin / startCoin). | ||
'''ROC5/hccrate05''' is on an APC switch. Pick the 'Outlet Status' Tab; click on ''On'' to the left of ''hccrate05'' on Outlet 1. Set the ''Control Action'' to ''Reboot Delayed'', click the checkbox to the left of ''hccrate05'', then click the ''Next>>'' button and click ''Apply'' on the next screen. ''If'' you know where hccrate05 is in the Counting House Electronics Room, you can power cycle it with the switch on the front panel. Turn it off, wait 5 seconds, and turn it | '''ROC5/hccrate05''' is on an APC switch. Pick the 'Outlet Status' Tab; click on ''On'' to the left of ''hccrate05'' on Outlet 1. Set the ''Control Action'' to ''Reboot Delayed'', click the checkbox to the left of ''hccrate05'', then click the ''Next>>'' button and click ''Apply'' on the next screen. ''If'' you know where hccrate05 is in the Counting House Electronics Room, you can power cycle it with the switch on the front panel. Turn it off, wait 5 seconds, and turn it | ||
back on. | back on. | ||
− | |||
− | |||
* ''Make an hclog when you do this!'' | * ''Make an hclog when you do this!'' | ||
==== Rebooting the DAQ computers ==== | ==== Rebooting the DAQ computers ==== | ||
− | In rare instances, we have to reboot the cdaql5 (HMS) and/or the cdaql6 ( | + | In rare instances, we have to reboot the cdaql5 (HMS) and/or the cdaql6 (coinc or NPS) computers. This is best done under the guidance of the DAQ expert, but the link to the general procedure is documented here: [https://logbooks.jlab.org/entry/4123883 https://logbooks.jlab.org/entry/4123883] |
= Live Time Display = | = Live Time Display = | ||
Line 170: | Line 147: | ||
Run the prescale GUI using one of these commands from a terminal in the SHMS or HMS DAQ session. '''Do this from a terminal in the appropriate CODA VNC session.''' | Run the prescale GUI using one of these commands from a terminal in the SHMS or HMS DAQ session. '''Do this from a terminal in the appropriate CODA VNC session.''' | ||
− | % | + | % go_prescale_COIN |
== How to pick a prescale value == | == How to pick a prescale value == |
Revision as of 10:53, 22 August 2023
How to kill/reset/restart the DAQ, or, "The DAQ is dead, now what..."
How to connect to VNC session =
ssh into cdaq@cdaql1 and from there type: go_nps_daq or go_coin_daq (they are the same).
If running HMS-standalone type go_hms_daq
If you are connected to the appropriate DAQ vncsession
If you are connected to the appropriate DAQ vncsession, and CODA has hung, or gotten into a funny state, then bring the terminal window at lower left to the foreground and type the appropriate kcoda / startCoda script, which depends on what you are running, which is probably coincidence
% killCoin for coincidence DAQ, kcoda for NPS-standalone, killHMS for HMS-standalone.
Wait for a bit (10 sec). Then restart coda by typing this in the same terminal:
% startCoin for coincidence DAQ, startCoda for NPS-standalone, startHMS for HMS-standalone.
You will then have to complete the 'standard' CODA steps:
- Choose 'Platform:Connect' from the CODA Run Control GUI menu bar.
- Click on the 'Tools' icon.
- Then you should be able to start a run as usual.
If you the components can't connect, it may be that the platform is not running, so you can restart it by typing "platform &" on coda@cdaql6. But first check the process list "ps awx | grep platform"
- Make an hclog and document the error you saw (screen snapshot, etc) if you choose to do this.
If the kcoda/startcoda process doesn't work
If the system does not restore using the kcoda/startcoda procedure, then you may need to reboot the ROCs following this process
Hall_C_DAQ#If_you_need_to_reboot_a_ROC.
Be patient, then try the kcoda/startcoda procedure as discussed in that section.
If the CODA vnc session disappeared and 'go_coin_daq' doesn't work
NOTE: Ask a DAQ expert and/or the RC before you do this. It really should never be needed.
If everything disappeared and 'go_shms_daq/go_hms_daq' doesn't work then you can bring things up from scratch outside the VNC session.
COIN Mode
% ssh coda@cdaql6
In that terminal, run:
% startCoin
NPS standalone
% ssh coda@cdaql6
In that terminal, run:
% startCoda
HMS standalone
% ssh coda@cdaql5
In that terminal, run:
% startHMS
If the Event Builder (EB) process keeps dying when you try to start a run
This often means there is a memory issue on one of the linux ROCs. It is simplest to follow the Reboot ROCs procedure to resolve this.
How to bring up the DAQ screens on a workstation
The DAQs run inside their own VNC sessions. They can be brought up on any of the Hall C Counting House machines by running these commands logged in as the 'cdaq' user:
Switching Back to Single Arm DAQs
% kcoda % go_COIN_DAQ_Disable
You will be prompted to reboot/power-cycle the HMS crates. Do so following Hall_C_DAQ#If_you_need_to_reboot_a_ROC. Then restart the DAQ in the SHMS DAQ session:
% startcoda
You should see more terminals pop up on the right associated with the additional DAQ components.
Start up the single Arm DAQs as usual. You will need to restore the single-arm CODA session type for the SHMS DAQ. See Hall_C_DAQ#SHMS_Single_Arm
If the system is being fussy. Reboot ALL of the crates following Hall_C_DAQ#If_you_need_to_reboot_a_ROC. Then try startcoda again.
If you need to reboot a ROC
If a ROC gets in a really bad state, its crate may need to be power cycled using the procedure and links below.
It pays to be a little patient with this process. Stagger turning the crate power back on by 10--20 seconds. For example, turn on hccrate01, wait 10s, turn on hccrate02, wait 10s, etc...
NOTE: Open a browser window in the CODA VNC session (usually there is one already running in the left-most workspace). All of the crate reset links are there along with stored login credentials.
COIN mode
Coincidence (COIN) mode uses both the NPS and HMS ROCs, so you will need to reboot all of them using the links in the two sub-sections below.
After you have power cycled all the ROCs, wait for 2--3 minutes then run kcodaCoin; and startCoin. If that doesn't work, call an Expert.
- Make an hclog when you do this!
SHMS (not used during NPS
Reboot them by clicking on the link, and cycling the power. Wait for 10s after clicking the 'power' button before clicking it again. The page will automatically refresh when it is ready.
After you have power cycled all the ROCs, wait for 2--3 minutes then run kcoda; and startcoda. If that doesn't work, call an Expert.
- Make an hclog when you do this!
HMS
The HMS has three ROCs. Follow these links to power-cycle:
- ROC01 (Counting House Electronics Room)
- ROC03 (HMS Electronics Hut -- the wire chambers)
- ROC05 (Counting House Electronics Room) --- On APC switch. See note below.
NPS
The NPS has five ROCs and five VTPs. The VTPs get power cycled when you cycle the ROCs.
- npsvme1 and npsvtp1 (NPS crate 1)
- npsvme2 and npsvtp2 (NPS crate 2)
- npsvme3 and npsvtp3 (NPS crate 3)
- npsvme4 and npsvtp4 (NPS crate 4)
- npsvme5 and npsvtp5 (NPS crate 5)
Reboot them by clicking on the link, and cycling the power. Wait for 10s after clicking the 'power' button before clicking it again. The page will automatically refresh when it is ready.
After you have power cycled all the ROCs, wait for 2--3 minutes then run the appropriate script (killCoin / startCoin).
ROC5/hccrate05 is on an APC switch. Pick the 'Outlet Status' Tab; click on On to the left of hccrate05 on Outlet 1. Set the Control Action to Reboot Delayed, click the checkbox to the left of hccrate05, then click the Next>> button and click Apply on the next screen. If you know where hccrate05 is in the Counting House Electronics Room, you can power cycle it with the switch on the front panel. Turn it off, wait 5 seconds, and turn it back on.
- Make an hclog when you do this!
Rebooting the DAQ computers
In rare instances, we have to reboot the cdaql5 (HMS) and/or the cdaql6 (coinc or NPS) computers. This is best done under the guidance of the DAQ expert, but the link to the general procedure is documented here: https://logbooks.jlab.org/entry/4123883
Live Time Display
If it isn't showing up (ie. after a kcoda/startcoda) then:
- Select the 'Live Time' tab on the right side of the GUI below the 'Run Status' box.
- Click on 'TS0x' in component list under 'Name' column on left of rcGUI to select that component.
- With 'TS0x' selected at the top of the GUI select Options:Charts:Add.
- The live time of 'TS0x' should now plot in the 'Live Time' tab.
Setting Prescales
Run the prescale GUI using one of these commands from a terminal in the SHMS or HMS DAQ session. Do this from a terminal in the appropriate CODA VNC session.
% go_prescale_COIN
How to pick a prescale value
The relationship between the prescale setting and the actual prescale value is somewhat complicated. You can click on the 'Help' button for details.
- The best way to do it is to type in the prescaled rate you want into the Target Rate field and hit return. The Prescaled Rate field will update to show you the rate the DAQ will be accepting.
- You can try adding or subtracting '1' to the 'Value' field if you want to try to tweak the Prescaled Rate a bit.
NOTE: You MUST hit SAVE *before* starting the run!
If the scaler rates in the prescale GUI are not updating
This can happen after CODA gets in a funny state, for example.
- Quit the prescale GUI (Exit button)
- Run the GUI again (as above).
EDTM Settings
Remotely adjustable EDTM
Currently set with a a command-line helper go_edtm
- There is a command-line helper
go_edtm
to set/readback this PV. (the prescale_GUI does not set it at the moment.) - More details are in this log entry: EDTM pulser switched to cdaqpi1 output
- The RPi that controls this is cdaqpi1 which runs an EPICS softIOC.
F250 Pedestal Updates
Overview
This How-To discusses the necessary steps required in order to take a pedestal run utilizing the single arm DAQ's. Furthermore, the steps required in-order to determine the appropriate FADC thresholds are discussed.
NOTE: This is for EXPERTS ONLY. If this is done poorly and not caught the FADCs will not work correctly and the data maybe garbage!
Taking Pedestal Runs
- Ensure that both single arm DAQ's are configured with the "fadcnothr" flag, which is activated via. of the pre-scale GUI, and the configuration has been saved
- The FADC's can either be in mode 9 or 10
- With both arms take at least 1000 cosmic or EDTM triggers and note the run numbers
Determining the FADC thresholds
- The following example will illustrate the necessary steps required to determine the FADC thresholds for SHMS ROC 2
- On the SHMS side, this procedure will have to be repeated for both ROC's 2 and 4
- On the HMS side, this procedure only has to be executed for ROC 1
- With the pedestal runs complete, open a terminal and SSH into cdaql1
ssh cdaq@cdaql1
- Setup the hallc-online analyzer
go_analysis
- Descend into the hallc-online hcana/podd directory
cd ../hcana/podd/hana_decode/apps
- Exectue the tstfadc_main.C script
./tstfadc
- Input the appropriate configurations: raw data file location, run number, number of events, spectrometer name, crate number
Enter the location of the raw CODA file (raw, raw.copiedtotape): raw Enter a Run Number (-1 to exit): 1537 Enter Number of Events to Analyze (-1 = All): -1 All Events in Run 1537 Will be Analayzed Enter the Spectrometer Name (hms or shms): shms Enter the Crate Number to be Analyzed: 2
- If successful, the for file "fadc_data.root" will have been produced
- In order to produce the threshold text file "thresholds.dat" one needs to execute the calc_thresh_hallc.C ROOT script
root -l ./calc_thresh_hallc.cxx
- Input the appropriate configurations: spectrometer name, crate number, FADC mode, threshold in channels
Enter the Spectrometer Name (hms or shms): shms Enter the Crate Number to be Analyzed: 2 Enter The Mode of The F250's: 9 Enter The Number of Channels Above Baseline the Threshold Should Be [40 (10 mV) recommended]: 40
- A ROOT file "fadc_ped_data.root" will have been created which contains the final fits and determines the baseline values and thus the threshold values which are written to the text file "thresholds.dat"
- Open the "thresholds.dat" file and have a sanity check the thresholds
- Most FADC channels should have thresholds set to 400-700 channels
- For channels set to 4095, these channels are empty
- For ROC2 slot 14 channels 12-15 are set to 1 by default since they are fast raster FADC channels
- For ROC4 slot 18 channels 12-15 are set to 1 by default since they are fast raster FADC channels
- In the event that a few thresholds are set to unrealistic values, simply open the "fadc_ped_data.root" file and perform the fit manually if possible
- If a manual fit is not possible, then a new pedestal run with more statistics is recommended
Loading the FADC Thresholds
- These instructions only pertain to the HMS at the moment. For NPS, it is different.
- In order to have the CRL's load the appropriate FADC threshold files the newly created "thresholds.dat" file must be placed in the correct location
- SSH into cdaql1 as coda
ssh coda@cdaql1
- Descend into the respective thresholds directory for the appropriate ROC
cd coda/config_files/SHMS/ROC02/thresholds
- Copy the newly created "thresholds.dat" into the current working directory and tag the "thresholds.dat" file with the current date
cp hana_decode/thresholds.dat thresholds_DDMONYYYY.dat
- Ascend one directory and symbolically link the newly created thresholds file as "thresholds.dat"
cd ../ ln -fs thresholds/thresholds_DDMONYYYY.dat thresholds.dat