Difference between revisions of "Elong-13-10-09"

From HallCWiki
Jump to navigationJump to search
(New page: ==b1 With Updated Rates Code== Updated the b1 plots since I made a number of changes to the b1 rates code cross-sections. Using Pzz=30% and SHMS-3 setting for the dilution factor. {| cla...)
 
Line 4: Line 4:
  
 
{| class="wikitable" style="text-align:center; border-collapse:collapse;" border="1"
 
{| class="wikitable" style="text-align:center; border-collapse:collapse;" border="1"
! colspan="2" | <math>E_{\mathrm{beam}}=11.0\mathrm{~GeV}</math>
+
! colspan="5" | <math>E_{\mathrm{beam}}=11.0\mathrm{~GeV}</math>
 
|-
 
|-
|<math>\mathrm{HMS~}\theta_{e'}=?^{\circ}</math><br>
+
|<math>\mathrm{HMS~}\theta_{e'}=12.523^{\circ}</math><br>
<math>\mathrm{HMS~}E'=?\mathrm{~GeV}</math><br>
+
<math>\mathrm{HMS~}E'=7.299\mathrm{~GeV}</math><br>
<math>\mathrm{HMS~}Q^2=?\mathrm{~(GeV/}c)^2</math><br>
+
<math>\mathrm{HMS~}Q^2=3.820\mathrm{~(GeV/}c)^2</math><br>
||<math>\mathrm{SHMS~}\theta_{e'}=?^{\circ}</math><br>
+
||<math>\mathrm{SHMS~1~}\theta_{e'}=7.346^{\circ}</math><br>
<math>\mathrm{SHMS~}E'=?\mathrm{~GeV}</math><br>
+
<math>\mathrm{SHMS~1~}E'=6.701\mathrm{~GeV}</math><br>
<math>\mathrm{SHMS~}Q^2=?\mathrm{~(GeV/}c)^2</math><br>
+
<math>\mathrm{SHMS~1~}Q^2=1.210\mathrm{~(GeV/}c)^2</math><br>
 +
||<math>\mathrm{SHMS~2~}\theta_{e'}=8.962^{\circ}</math><br>
 +
<math>\mathrm{SHMS~2~}E'=7.447\mathrm{~GeV}</math><br>
 +
<math>\mathrm{SHMS~2~}Q^2=2.000\mathrm{~(GeV/}c)^2</math><br>
 +
||<math>\mathrm{SHMS~3~}\theta_{e'}=9.848^{\circ}</math><br>
 +
<math>\mathrm{SHMS~3~}E'=7.958\mathrm{~GeV}</math><br>
 +
<math>\mathrm{SHMS~3~}Q^2=2.580\mathrm{~(GeV/}c)^2</math><br>
 
|-  
 
|-  
| colspan="2" | '''30 Day Measurement'''<br>
+
| colspan="5" | '''30 Day Measurement'''<br>
 
[[Image:2013-10-09-b1.png|1000px]][[Image:2013-10-09-b1-cs.png|350px]]
 
[[Image:2013-10-09-b1.png|1000px]][[Image:2013-10-09-b1-cs.png|350px]]
 
|-   
 
|-   
 
|}
 
|}

Revision as of 17:01, 8 October 2013

b1 With Updated Rates Code

Updated the b1 plots since I made a number of changes to the b1 rates code cross-sections. Using Pzz=30% and SHMS-3 setting for the dilution factor.

<math>E_{\mathrm{beam}}=11.0\mathrm{~GeV}</math>
<math>\mathrm{HMS~}\theta_{e'}=12.523^{\circ}</math>

<math>\mathrm{HMS~}E'=7.299\mathrm{~GeV}</math>
<math>\mathrm{HMS~}Q^2=3.820\mathrm{~(GeV/}c)^2</math>

<math>\mathrm{SHMS~1~}\theta_{e'}=7.346^{\circ}</math>

<math>\mathrm{SHMS~1~}E'=6.701\mathrm{~GeV}</math>
<math>\mathrm{SHMS~1~}Q^2=1.210\mathrm{~(GeV/}c)^2</math>

<math>\mathrm{SHMS~2~}\theta_{e'}=8.962^{\circ}</math>

<math>\mathrm{SHMS~2~}E'=7.447\mathrm{~GeV}</math>
<math>\mathrm{SHMS~2~}Q^2=2.000\mathrm{~(GeV/}c)^2</math>

<math>\mathrm{SHMS~3~}\theta_{e'}=9.848^{\circ}</math>

<math>\mathrm{SHMS~3~}E'=7.958\mathrm{~GeV}</math>
<math>\mathrm{SHMS~3~}Q^2=2.580\mathrm{~(GeV/}c)^2</math>

30 Day Measurement

2013-10-09-b1.png2013-10-09-b1-cs.png