Difference between revisions of "Kaon LT Status Page"
From HallCWiki
Jump to navigationJump to searchLine 15: | Line 15: | ||
|Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 || Completed || 43 % of min statistical goal [https://logbooks.jlab.org/entry/3603234] | |Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 || Completed || 43 % of min statistical goal [https://logbooks.jlab.org/entry/3603234] | ||
|- | |- | ||
− | |Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 || | + | |Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 || Al next || 58% of min statistical goal taken on LH2; will take Al once beam is restored |
|- | |- | ||
|Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 || To do || | |Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 || To do || |
Revision as of 08:56, 6 October 2018
- Table of Kaon LT Physics Status
Item | Status | Comment |
Q2=3.0 W=2.32 x=0.40 theta_Shms=15.18 | Completed | |
Q2=3.0 W=2.32 x=0.40 theta_Shms=18.18 | Completed | |
Q2=3.0 W=2.32 x=0.40 theta_Shms=21.18 | Completed | Summary plot of all three settings |
Q2=2.115 W=2.95 x=0.21 theta_Shms=7.74 | Completed | ~43 % of min statistical goal [1] |
Q2=2.115 W=2.95 x=0.21 theta_Shms=10.74 | Completed | 43 % of min statistical goal [2] |
Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 | Completed | 43 % of min statistical goal [3] |
Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 | Al next | 58% of min statistical goal taken on LH2; will take Al once beam is restored |
Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 | To do | |
Q2=4.4 W=2.74 x=0.4 theta_Shms=15.81 | To do |
- Table of Kaon LT Commissioning Status.
Item | Status | Comment |
Detector Checkout | Completed | |
HMS Trigger PID | Completed | |
SHMS Trigger PID | Completed | |
BPM calibration check | Not done | |
Beam energy measurement | Completed [4] | |
High and low current BCM calibration | Completed low current up to 57uA | Calibration plots |
HMS/SHMS optics study | Completed | |
HMS/SHMS single arm elastic | Completed | |
HMS/SHMS coincidence ep elastic | Completed | 25K events ( wanted 50K) |
Golden HMS/SHMS sieve run | Completed | Used to check the stability of beam positions at different energies |
Luminosity scan | Not done | Need fairly stable 65uA |