Elong-13-10-09b

From HallCWiki
Jump to navigationJump to search

Azz Rates by Spectrometer

Same calculations as done for the combined optimized rates, except that they're now shown with the statistics that are contributed by each spectrometer. For this plot, the dilution factors were calculated individually for each spectrometer.


<math>E_{\mathrm{beam}}=6.6\mathrm{~GeV}</math>
<math>\mathrm{HMS~}\theta_{e'}=12.382^{\circ}</math>

<math>\mathrm{HMS~}E'=5.862\mathrm{~GeV}</math>
<math>\mathrm{HMS~}Q^2=1.800\mathrm{~(GeV/}c)^2</math>

<math>\mathrm{SHMS~}\theta_{e'}=8.231^{\circ}</math>

<math>\mathrm{SHMS~}E'=6.252\mathrm{~GeV}</math>
<math>\mathrm{SHMS~}Q^2=0.850\mathrm{~(GeV/}c)^2</math>

1 Week Measurement

2013-10-09-e-66-specsplit-1week.png2013-10-07-e-66-opt-cs.png

2 Week Measurement

2013-10-09-e-66-specsplit-2week.png2013-10-07-e-66-opt-cs.png

--E. Long 22:15, 8 October 2013 (UTC)