Kaon LT Status Page

From HallCWiki
Revision as of 17:12, 6 October 2018 by Rambrose (talk | contribs)
Jump to navigationJump to search
  • Table of Kaon LT Physics Status
Item Status Comment
Q2=3.0 W=2.32 x=0.40 theta_Shms=15.18 Completed
Q2=3.0 W=2.32 x=0.40 theta_Shms=18.18 Completed
Q2=3.0 W=2.32 x=0.40 theta_Shms=21.18 Completed Summary plot of all three settings
Q2=2.115 W=2.95 x=0.21 theta_Shms=7.74 Completed ~43 % of min statistical goal [1]
Q2=2.115 W=2.95 x=0.21 theta_Shms=10.74 Completed 43 % of min statistical goal [2]
Q2=2.115 W=2.95 x=0.21 theta_Shms=13.74 Completed 43 % of min statistical goal [3] Summary plot of all three settings
Q2=4.4 W=2.74 x=0.4 theta_Shms=9.81 58% of min goal 58% of min statistical goal taken on LH2; Al done Summary plot of this setting
Q2=4.4 W=2.74 x=0.4 theta_Shms=12.81 Al in progress
Q2=4.4 W=2.74 x=0.4 theta_Shms=15.81 To do
  • Table of Kaon LT Commissioning Status.
Item Status Comment
Detector Checkout Completed
HMS Trigger PID Completed
SHMS Trigger PID Completed
BPM calibration check Not done
Beam energy measurement Completed [4]
High and low current BCM calibration Completed low current up to 57uA Calibration plots
HMS/SHMS optics study Completed
HMS/SHMS single arm elastic Completed
HMS/SHMS coincidence ep elastic Completed 25K events ( wanted 50K)
Golden HMS/SHMS sieve run Completed Used to check the stability of beam positions at different energies
Luminosity scan Not done Need fairly stable 65uA