Rough / High-level sketch of d2n kinematic settings

Reduced kinematics list to accommodate limited beam time (dropped 1/4 of kinematics)

      ---------  Beam Params ----------
            E_beam = 10.4 GeV/c
            I_beam = 30 uA
            P_targ = 0.50
            P_beam = 0.80
          ---------  HMS ----------
       E'    theta    x        Q2       W
*C    -4.0   20.0     0.418    5.018   2.806 [Starting here] --  Only setting compatible with SOLID Cherenkov small-angle test.
 A    -4.2   13.5     0.207    2.414   3.178
 B    -4.2   16.4     0.305    3.554   2.993
          --------- SHMS ----------
       E'    theta    x       Q2      W
*X    -7.5   11.0     0.527   2.866   1.859  [Starting here]
 Y    -6.4   14.5     0.565   4.240   2.036
 Z    -5.6   18.0     0.633   5.701   2.046


Run / Shift Schedule

  • We started taking on Swing on Aug 7 (took a few days for beam to stabilize)
  • Beam is scheduled to turn off 8am, Sept 21 (roughly 6 weeks) [1]
  • Hall C Shift Schedule

Data Collection Status

  • Data collection status is best monitored using d2n_status_table on cdaq@cdaql1
[cdaq@cdaql1 ~]$ go_analysis pro
cdaq@cdaql1:~/polhe3/production/hallc_replay$ d2n_status_table 
  • That table is also posted to the HCLog every shift with the subject "Recent SHMS and HMS run list".
    • You can use the Hall C Run List Summaries link under the HCLog Useful Links sidebar on the right as a shortcut.
  • The runtimes and estimated yields are based on Rate Estimate Updates (19 Mar 2020) by Wolfgang
    • (NOTE: Ignore the primed kinematics in the file, they are not relevant anymore.)