Elong-14-04-15

From HallCWiki
Revision as of 10:17, 15 April 2014 by Ellie (talk | contribs) (New page: =Pzz=15% with ND3 Scenario= In a worst case scenario where we are stuck with Pzz=15% on an ND3 target, I looked into what single kinematics point we could spend all of our time on that wo...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Pzz=15% with ND3 Scenario

In a worst case scenario where we are stuck with Pzz=15% on an ND3 target, I looked into what single kinematics point we could spend all of our time on that would give us the best measurement.

First I did a Q^2 scan of the SHMS

2014-04-15-shms-q2-scan.gif

This was followed by an x scan of the HMS

2014-04-15-hms-x-scan.gif

and an x scan of the SHMS.

2014-04-15-shms-x-scan.gif

After each of these, it looked like our best point was to put the central SHMS at x=0.28 and Q^2=1.47 with the HMS at x=0.41 and Q^2=3.33. If we do that, and are ok lowering our W^2, we can increase the statistics in the x=0.4 point by opening up the cut

2014-04-15-w2-cut-scan.gif