Charge Feedback Parity DAQ
From HallCWiki
The Charge Asymmetry Feedback system is controlled by the Hall A Parity DAQ.
When Hall A is in production mode, the Hall A shift crew will manage the Parity DAQ and control feedback for both Hall A and Hall C beams.
If the Hall A Counting House is not staffed, then Hall C must negotiate with the Parity group to ensure that the Parity DAQ is still running.
- This must be running for all 3He production data! (And should be running in general.)
- The state of this system is monitored in the Hall C alarm handler, and can be overseen by the Hall C Shift crew using the stripchart on the left large wall display (see below).
Instructions
- Parity DAQ Running - with Hall C Feedback passively running (Aug 02, 2020 HClog entry)
- Bring up this vnc session using
go_parity_feedback
under the cdaq account.
- Hall C running parity DAQ for charge feedback (Feb 12, 2020 HCLog entry) -- OLD, just for reference.
Useful Commands
go_parity
Injector parity settings (IHWP status, Hall Laser IA settings, etc)go_parity_feedback
Bring up the Parity DAQ charge feedback VNC session (if Hall C is running alone; see below)go_Qasym_stripchart
Bring up the Hall C Charge Asym monitoring stripcharts (these should always be up on the big wall screens)
How to run the flipper script
Needs to be done when insertable half wave plate (IHWP) state is changed
- This only has to be done when Hall A is not controlling the Aq feedback
- stop the run (parity daq)
- in the vnc session from above
ssh apar@adaq2
cd ~/feedback2019
./FlipPCvaluesHallC
You should see the hallc_IACell_setting variable change on the wall./checkPCvaules
- start a run (parity daq)