12 GeV HMS Optics Data
From HallCWiki
Contents
HMS optics page
Introduction
- HMS is a Q1-Q2-Q3-D magnet system
- New drift chamber were installed in HMS for 12 GeV.
- HMS delta matrix has not been optimized in the 12 GeV era. Still delta matrix from the 6 GeV era.
- All HMS magnets saturate when magnet is set above 5 GeV.
HMS optics at low momentum
HMS Optics at 6.6 GeV/c Table
Run Number | Beam Energy (GeV) | HMS Central Momentum (GeV/c) | HMS Angle (Deg) | Collimator Type | Target | Delta (%) | Comment |
4819 | 10.5965 | 6.59 | -13.005 | Sieve Slit | -10, 0, +10 cm Carbon Foil | N/A | 6.6 GeV/c Carbon-Sieve Data |
4805 | 10.5965 | 6.59 | -18.8 | Large | LH2 | +0.34 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.84204 T |
4806 | 10.5965 | 6.59 | -18.8 | Large | LH2 | +0.34 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.84204 T |
4808 | 10.5965 | 6.59 | -18.8 | Large | LH2 | +0.34 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.83462 T |
4811 | 10.5965 | 6.59 | -18.8 | Large | LH2 | +0.34 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.83462 T |
4816 | 10.5965 | 6.59 | -17.2 | Large | LH2 | +6.84 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.83467 T |
4817 | 10.5965 | 6.59 | -17.2 | Large | LH2 | +6.84 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.83467 T |
4821 | 10.5965 | 6.59 | -19.755 | Large | LH2 | -3.41 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.831 T |
4824 | 10.5965 | 6.59 | -19.755 | Large | LH2 | -3.41 | 6.6 GeV/c Delta Scan Data; NMR Readback = N/A |
4825 | 10.5965 | 6.59 | -19.755 | Large | LH2 | -3.41 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.831 T |
4821 | 10.5965 | 6.59 | -19.755 | Large | LH2 | -3.41 | 6.6 GeV/c Delta Scan Data; NMR Readback = 1.831 T |
HMS optics at 6.6 GeV
- Fall 2018 take series of optics and elastic runs.
- List of runs at Kaon Run list.
- Initial set of runs (4734-4741,4768-4773) with Optics 1 target (-10,0,10) and varied dipole and Quads to try and get ytar vs yptar
- Online Conclusion that it was not converging.
- Series of elastic runs with HMS angle changes to move the elastic across the focal plane. all runs at nominal magnet settings.
- Runs 4805-4811 HMS at 18.79deg LH2, Runs 4812-13 DUmmy
- Runs 4816-17 HMS at 17.20 deg Lh2, Runs 4814-15 Dummy
- Runs 4821,24,25 HMS at 19.755deg LH2, Run 4822 Dummy.
- Series of SHMS (proton) and HMS (electron) ep coincidence
- SHMS p = +4.840 ang = 26.147 HMS p = -6.590 ang = 18.845
- Runs 4855-4860,4862-4963 LH2
- run 4864 dummy
- Series of optics 1 with Sieve runs
- Optic 1 target Run 4819 at 13.005deg.
- Optic 1 target RUn 4820 at 13.005deg (modified Q1 current).
- Single carbon Run 4818 at 13.005deg.
HMS optics at 6.3 GeV
- Fall 2018 take series of optics and elastic runs.
- List of runs at Kaon Run list.
- Initial set of runs 4756-4757 with HMS dipole at +0.685% above nominal and Q1 + 0.3% with Optics 1 target
- Set of runs 4758-65 with HMS dipole at at +0.685% above nominal and Quads at nominal with Optics 1 target.
- Run 4774 with HMS magnets all at nominal with Optics 1 target.
- Run 4775 with HMS dipole at 1.002*nominal with Optics 1 target.
- Run 4776 with HMS dipole at 1.003*nominal with Optics 1 target.
- Run 5335 with HMS dipole at nominal for 6.358 with Optics 1 target.
HMS optics at momentum greater than 5 GeV
- Initial study of HMS saturation in Spring18
- Looked at the yptar versus ytar correlation at HMS momentum 5.1 to 5.9 GeV
- Fixed the Q1-Q2-Q3 to settings for the given set momentum and then varies the HMS dipole
- Logbook entry about the measurement.