Thursday, Mar. 22, 2018
Where do we start we SHMS?
--> we start at 33 deg (SHMS is at 32.975 deg) and -1.7 GeV/c (negative polarity)
--> here we take data on LH2, LD2 and Al
Where do we go next with SHMS?
--> we change polarity to + and start the CSB measurements (highest to lowest angle, no need to cycle magnets)
Where do we start with HMS?
--> we start at 59 deg (HMS is at 58.98 deg) and +1.2 GeV/c (CSB measurements)
--> we have some LH2 running at +1.2 GeV/c and then we can go to the last momentum setting at this angle: +1.05 GeV/c; this will complete the F2 physics running with HMS
Where do we go next with HMS?
--> change polarity to negative and take a Cherenkov eff./calibration run and then do boiling studies (it should not impede the SHMS running though)
Simona's checklist before running
--> check SHMS and HMS angles (again), set SHMS to -1.7 and HMS to +1.2 GeV/c
--> trigger types should be: ELREAL for SHMS and ELCLEAN for HMS
--> check the E.D.T. setup for SHMS and HMS (should correspond to ELREAL and ELCLEAN, respectively)
--> check PID trigger legs thresholds
--> check hodoscope thresholds
--> set EDTM rate to 3 Hz (need to see the physics rates again)
--> When beam comes:
--> beam spot on the YAG without raster --> turn raster on --> C hole run with SHMS