History of SIMC CVS
Mar 14, 2012
Major changes for SHMS subroutines.
- [Makefile] : add file shared/rotate_vaxis.o
- [simc.f] : more apertures have been added to SHMS spectrometer code mc_shms.f, so additional "STOP" counters added.
- [spectrometers.inc] : Increased max_class = 41 . Added variables to common block "track"
- [shared/transp.f] : Modified SHMS forward optics matrix to shms_forward_cosy_2011_dipole26cm_dm1.2_nov9.dat
- [shared/rotate_vaxis.f] : New code to do rotation around vertical axis. Needed for apertures in SHMS bender
- [shms/structures_shms.inc] : Add "STOP" counters for all new SHMS apertures
- [shms/shms_recon_fit_90deg_1cm_5th_order.dat] : New recon optics matrix
- [shms/shms_forward_cosy_2011_dipole26cm_dm1.2_nov9.dat] : New forward optics matrix
- [shms/mc_shms_recon.f] : Recon Optics matrix shms/shms_recon_fit_90deg_1cm_5th_order.dat
- [shms/mc_shms_hut.f] : Changes for implementing SHMS detector
- [shms/hut.inc] : Changes for implementing SHMS detector
- [shms/mc_shms.f] Major changes. Implement the horizontal bender. Updated info for other magnets.
- [shms/apertures_shms.inc] Implement the horizontal bender. Updated info for other magnets.
Nov 21, 2011
Update radc.f : In subroutine lambda_dave, correct the formula for the proton lambda calculation to agree with formula 59 in PRC 64 054610. Previously, the calculation was missing the factor e3/p3.
June 29, 2011
Updated event.f : When upgrading SIMC for gfortran in June 2009 calls to trip_thru_target for the scattered electron and hadron were moved from the end of the complete_ev subroutine to the end of the generate subroutine. The reason for the calls to trip_thru_target at end of the complete_ev subroutine is that the call to radc_init_ev at the very end of the complete_ev needs information calculated by trip_thru_target. So moving these calls was a mistake. In effect, the radc_init_ev was using info calculated for the previous event.