= Overview =
 
= Overview =
  
This How-To discusses the necessary steps required in order to take a pedestal run utilizing the single arm DAQ.  Furthermore, the steps required in-order to determine the appropriate FADC thresholds are discussed.  This [https://hallcweb.jlab.org/wiki/index.php/Hall_C_DAQ How-To] covers the details required to operate the Hall-C DAQ.
+
This How-To discusses the necessary steps required in order to take a pedestal run utilizing the [https://hallcweb.jlab.org/wiki/index.php/Hall_C_DAQ single arm DAQ's].  Furthermore, the steps required in-order to determine the appropriate FADC thresholds are discussed.
 +
 
 +
== Taking Pedestal Runs ==
 +
 
 +
* Ensure that both single arm DAQ's are configured with the "fadcnothr" flag, which is activated via. of the pre-scale GUI, and the configuration has been saved
 +
* With both arms take at least 1000 cosmic or EDTM triggers and note the run numbers
 +
 
 +
== Determining the FADC thresholds ==
 +
 
 +
* With the pedestal runs complete, open a terminal and SSH into cdaql1
 +
  ssh cdaq@cdaql1
 +
* Setup the hallc-online analyzer
 +
go_analysis
 +
* Descend into the hallc-online hcana/podd directory
 +
cd ../hcana/podd/hana_decode/

Revision as of 13:41, 6 December 2017

Overview

This How-To discusses the necessary steps required in order to take a pedestal run utilizing the single arm DAQ's. Furthermore, the steps required in-order to determine the appropriate FADC thresholds are discussed.

Taking Pedestal Runs

  • Ensure that both single arm DAQ's are configured with the "fadcnothr" flag, which is activated via. of the pre-scale GUI, and the configuration has been saved
  • With both arms take at least 1000 cosmic or EDTM triggers and note the run numbers

Determining the FADC thresholds

  • With the pedestal runs complete, open a terminal and SSH into cdaql1
ssh cdaq@cdaql1
  • Setup the hallc-online analyzer
go_analysis
  • Descend into the hallc-online hcana/podd directory
cd ../hcana/podd/hana_decode/