Cabling, power supply modules

The existing cables for the standard Hall-C spectrometers (HMS and SOS) will be used for the signal cables for the ENGE, HKS detectors, though some of them are broken and repair work is necessary. The HV cables exist from G0 patch in Hall C to the 2nd floor of the counting house. The HV crates on the 2nd floor can be used for us.

Table 19 summarizes the number of requires BNC/HV cables and table 20 does the existing cables.


表 19: Required number of signal and HV cables
  signal HV
EHODO 204 102
EDC   5
ENGE total 153 107
HTF 176 88
HAC 42 42
HWC 48 48
HDC   8
HKS total 266 186
Fission 24 3
TDC/ADC/ROC 12  
gate,control    
Grand total 506 296


表 20: The number of cables going upstairs and that could be used for ENGE-HKS
Signal cables  
Used for number of cables  
HMS 200  
SOS 200  
spare 180  
HV cables  
G0 600  

For HKS and Enge drift chambers, low voltage high current power supplies are necessary (section 6.3). Acopian DC power supplies are used for SOS and they will also work for HKS and Enge. Low current, low voltage, but adjustable voltage power supplies are needed for threshold setting of N277 amp-discriminator cards.