: Trigger study : Experimental procedures : Background study   目次

Detector component study

Although all the detectors are to be thoroughly tested before they are installed, performance of the detector components will be examined with beams, first with low beam current and later with the full beam current of around 30 $\mu $A. At this stage, it is important to tune the HV settings for each PMT and then adjust the timing for logics. In addition, the drift chamber operating condition under the required beam intensity environment is to be optimized, that is, HV, threshold voltages and timing of the start signals. Furthermore, the threshold level for water and aerogel Cerenkov counters will be adjusted with real events so as to optimize the rejection efficiencies against pions and protons but still keep high efficiencies for kaons.



Satoshi N. Nakamura 平成16年12月1日