Jefferson Lab Hall C Logbook for July 04 - Full Listing
Main INDEX
Wednesday
88150 07/28/04 17:24 jroche cosmic data taking
88147 07/28/04 16:57 smithg Target warmup completed
88146 07/28/04 15:54 cdaq Beam Time Accounting
88145 07/28/04 12:24 horn FR correlation - figures
88144 07/28/04 11:54 gaskell FR calibration in engine wrong?
88143 07/28/04 09:40 M Jones Hall C beam energy measurement
88142 07/28/04 08:28 cdaq Beam Time Accounting
88141 07/28/04 07:54 bruell Owl shift summary
88140 07/28/04 04:30 horn Beam gone again
88139 07/28/04 03:54 cdaq Run 50032: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88138 07/28/04 01:18 horn FSD problem
88137 07/28/04 00:48 cdaq Run 50031: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88136 07/28/04 00:45 cseely Target change to LH2 from Al dummy
88135 07/28/04 00:45 cdaq Run 50030: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88134 07/28/04 00:20 horn Target for run 50029 is Dummy
88133 07/28/04 00:10 cdaq Run 50029: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88132 07/28/04 00:06 cseely target checklist
88131 07/28/04 00:04 Y. Liang Shift Summary
88130 07/28/04 00:04 cdaq Beam Time Accounting
Tuesday
88128 07/27/04 23:55 cdaq Run 50028: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88127 07/27/04 23:38 clasie bpm/bcm screenshots
88126 07/27/04 23:36 clasie bpm/bcm screenshots
88125 07/27/04 23:26 cdaq Run 50027: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88124 07/27/04 22:59 clasie MCC called, beam is down
88123 07/27/04 22:40 cdaq Run 50026: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88122 07/27/04 22:10 cdaq Run 50025: Carbon,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88121 07/27/04 21:42 cdaq Run 50024: Carbon,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88120 07/27/04 21:14 cdaq Run 50023: Carbon,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88119 07/27/04 20:58 cdaq Run 50022: Carbon,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88118 07/27/04 20:29 cdaq Run 50021: Carbon,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88117 07/27/04 19:52 cdaq Run 50020: LD2,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88116 07/27/04 19:37 clasie 50015 and 50016 were LH2 runs
88115 07/27/04 19:26 cdaq Run 50019: LD2,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88114 07/27/04 19:15 clasie Ethane bottle
88113 07/27/04 18:51 cdaq Run 50018: Dummy,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88112 07/27/04 18:50 clasie ethane alarm
88111 07/27/04 18:38 clasie Etahne hasmaster alarm
88110 07/27/04 18:21 clasie HMS Q1 trip
88109 07/27/04 18:15 cdaq Run 50017: Dummy,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88108 07/27/04 18:11 clasie Target: move to dummy
88107 07/27/04 17:32 cdaq Run 50016: Dummy,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88106 07/27/04 17:17 Y. Liang change the kinematics of HMS and SOS
88105 07/27/04 17:13 cdaq Run 50015: Dummy,SOS P=1.73 th= 32.32, HMS P=2.074, th=19.99
88104 07/27/04 16:58 clasie HMS power supply replaced
88103 07/27/04 16:54 clasie Target: move to hydrogen
88102 07/27/04 16:50 clasie Target: checklist
88101 07/27/04 16:20 clasie HMSQ3 reboot
88100 07/27/04 16:02 cdaq Beam Time Accounting
88099 07/27/04 15:59 L. Tang Shift summary
88098 07/27/04 15:56 cdaq Run 50014: Dummy,SOS P=-1.19th= 27.76, HMS P=2.793, th=13.60
88097 07/27/04 15:35 cdaq Run 50013: Dummy,SOS P=-1.19th= 27.76, HMS P=2.793, th=13.60
88096 07/27/04 15:33 fomin target moved from LH2 to Al Dummy
88095 07/27/04 15:16 cdaq Run 50012: LH2,SOS P=-1.19th= 27.76, HMS P=2.793, th=13.60
88094 07/27/04 15:07 ddutta Arc Energy measurement
88093 07/27/04 14:52 cdaq Run 50011: LH2,SOS P=-1.19th= 27.76, HMS P=2.793, th=13.60
88092 07/27/04 14:30 cdaq Run 50010: LH2,SOS P=-1.19th= 27.76, HMS P=2.793, th=13.60
88091 07/27/04 14:26 L. Tang HMS rotation
88090 07/27/04 14:05 hcf 49990 was probably 1/2 junk, too
88089 07/27/04 13:18 L. Tang HMS Q2
88088 07/27/04 13:15 cdaq Run 50009: LH2,SOS P=-1.19th= 27.76, HMS P=2.793, th=13.60
88087 07/27/04 13:11 L. Tang HMS Q2
88086 07/27/04 13:11 fomin target moved from Au to LH2
88085 07/27/04 13:09 fomin target camera
88084 07/27/04 12:50 cdaq Run 50008: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88083 07/27/04 12:20 cdaq Run 50007: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88082 07/27/04 11:45 cdaq Run 50006: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88081 07/27/04 11:12 cdaq Run 50005: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88080 07/27/04 10:38 cdaq Run 50004: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88079 07/27/04 10:28 L. Tang Beam energy measurement
88078 07/27/04 08:36 cdaq Run 50003: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88077 07/27/04 08:11 bruell owl shift summary
88076 07/27/04 08:07 cdaq Beam Time Accounting
88075 07/27/04 08:06 fomin target checklist
88074 07/27/04 08:05 cdaq Run 50002: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88073 07/27/04 07:36 cdaq Run 50001: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88072 07/27/04 07:32 cseely cleared cryotarget alarm (the white 'v's)
88071 07/27/04 07:30 cseely cryotarget reboot - smooth recovery
88070 07/27/04 07:09 horn ROC 3 status
88069 07/27/04 07:04 cdaq Run 50000: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88068 07/27/04 07:02 cseely shift checklist scans
88067 07/27/04 06:43 cseely crotarget reboot - smooth recovery
88066 07/27/04 06:34 cdaq Run 49999: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88065 07/27/04 06:22 horn HMS magnets
88064 07/27/04 06:11 cseely bpm and bcm screens
88063 07/27/04 06:08 horn Runs 49991-49997 are junk
88062 07/27/04 06:04 cdaq Run 49998: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88061 07/27/04 05:47 cdaq Run 49997: DAQ TEST
88060 07/27/04 05:43 cdaq Run 49996: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88059 07/27/04 05:33 cdaq Run 49995: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88058 07/27/04 05:28 cdaq Run 49994: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88057 07/27/04 05:15 horn ROC 3 died during run 49990
88056 07/27/04 05:10 cseely scattering chamber vacuum alarm - and IOC reboot
88055 07/27/04 04:38 cdaq Run 49993: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88054 07/27/04 04:36 cdaq Run 49992: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88053 07/27/04 04:32 cdaq Run 49991: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88052 07/27/04 04:00 cdaq Run 49990: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88051 07/27/04 03:33 horn HMS Q2 trip at end of 49988
88050 07/27/04 03:28 cdaq Run 49989: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88049 07/27/04 02:48 horn Run 49987 - short run due to beam position adjustments
88048 07/27/04 02:38 cdaq Run 49988: 6% Au, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88047 07/27/04 02:36 cdaq Run 49987: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88046 07/27/04 02:33 cseely target change: from Cu to Au
88045 07/27/04 02:13 cdaq Run 49986: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88044 07/27/04 01:53 cdaq Run 49985: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88043 07/27/04 01:39 cseely Q3 reboot
88042 07/27/04 01:30 cdaq Run 49984: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88041 07/27/04 00:58 cseely cryotarget IOC reboot - recovery was smooth
88040 07/27/04 00:48 cdaq Run 49983: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88039 07/27/04 00:29 cdaq Run 49982: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88038 07/27/04 00:23 cseely target checklist
88037 07/27/04 00:16 cdaq Run 49981: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88036 07/27/04 00:11 akopper swing shift summary
88035 07/27/04 00:02 cdaq Beam Time Accounting
Monday
88034 07/26/04 23:40 cdaq Run 49980: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88033 07/26/04 23:21 clasie sos thresholds changed back
88032 07/26/04 23:02 cdaq Run 49979: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88031 07/26/04 22:49 clasie updated sos thresholds
88030 07/26/04 22:43 cdaq Run 49978: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88029 07/26/04 22:35 akopper more problems
88028 07/26/04 22:17 clasie Target: change to copper
88027 07/26/04 21:12 clasie problems making the ARC energy measurement
88026 07/26/04 20:44 clasie arc energy measurement
88025 07/26/04 20:32 akopper status
88024 07/26/04 19:58 clasie HMS drift chamber trip
88023 07/26/04 17:59 clasie Target: move to empty
88022 07/26/04 16:55 clasie MCC is bringing RF up
88021 07/26/04 16:21 clasie Target: checklist
88020 07/26/04 16:05 L.Tang Shift summary
88019 07/26/04 16:05 cdaq Beam Time Accounting
88018 07/26/04 15:53 okayasu HMS Q3 tripped
88017 07/26/04 13:29 mack Gobal BCM Calibration for Summer04
88016 07/26/04 10:45 okayasu HV checklist
88015 07/26/04 10:44 mack BCM calibration is stable
88014 07/26/04 09:51 gaskell/seel sSCIN scaler fixed
88013 07/26/04 09:43 cdaq Run 49977: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88012 07/26/04 09:18 cdaq Run 49976: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88011 07/26/04 09:18 cdaq Run 49975: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88010 07/26/04 08:06 bruell owl shift summary
88009 07/26/04 08:05 cdaq Beam Time Accounting
88008 07/26/04 07:47 cseely scan mask errors
88007 07/26/04 07:03 cdaq Run 49974: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88006 07/26/04 06:49 cdaq Run 49973: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88005 07/26/04 06:37 cdaq Run 49972: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88004 07/26/04 06:23 cdaq Run 49971: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88003 07/26/04 06:22 cseely bpm and bcm screens
88002 07/26/04 06:08 cdaq Run 49970: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88001 07/26/04 05:54 cdaq Run 49969: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
88000 07/26/04 05:53 cseely equipment checklist scans
87999 07/26/04 05:52 cseely equipment checklist
87998 07/26/04 05:43 cseely SOS optics plot
87997 07/26/04 05:41 cdaq Run 49968: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87996 07/26/04 05:29 cseely put in SOS LARGE collimator
87995 07/26/04 05:29 cdaq Run 49967: 6% Cu, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87994 07/26/04 05:26 cseely moving to Cu(6%) target from C(3%) target
87993 07/26/04 05:19 cdaq Run 49966: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87992 07/26/04 05:18 cseely screen shot of comfort screen during optics run: 49965
87991 07/26/04 05:16 cdaq Run 49965: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87990 07/26/04 05:11 cseely SOS sieve slit put in for optics run on C(3%)
87989 07/26/04 04:54 cdaq Run 49964: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87988 07/26/04 04:41 cdaq Run 49963: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87987 07/26/04 04:28 cdaq Run 49962: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87986 07/26/04 04:14 cdaq Run 49961: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87985 07/26/04 04:00 cdaq Run 49960: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87984 07/26/04 03:47 cdaq Run 49959: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87983 07/26/04 03:37 cdaq Run 49958: 3% C, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87982 07/26/04 03:29 cseely chaging to C(3%) target from LD2
87981 07/26/04 03:19 cdaq Run 49957: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87980 07/26/04 03:12 cseely BCM calibration run: 49955
87979 07/26/04 03:07 cdaq Run 49956: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87978 07/26/04 02:46 bruell runs 49945-49950 are junk
87977 07/26/04 01:46 cdaq Run 49955: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87976 07/26/04 01:33 cdaq Run 49954: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87975 07/26/04 01:23 cdaq Run 49953: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87974 07/26/04 01:13 cdaq Run 49952: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87973 07/26/04 01:03 cdaq Run 49951: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87972 07/26/04 01:02 cdaq Run 49951: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87971 07/26/04 00:58 cdaq Run 49949: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87970 07/26/04 00:56 cdaq Run 49948: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87969 07/26/04 00:51 cdaq Run 49947: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87968 07/26/04 00:50 cdaq Run 49947: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87967 07/26/04 00:42 cdaq Run 49945: LD2 4cm, SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87966 07/26/04 00:39 cseely target checklist
87965 07/26/04 00:31 cseely changing to LD2 target from Al Dummy target.
87964 07/26/04 00:20 Seely swing shift summary
87963 07/26/04 00:06 cdaq Beam Time Accounting
Sunday
87962 07/25/04 23:59 cdaq Run 49944: dummy,SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87961 07/25/04 23:55 okayasu Target change
87960 07/25/04 23:16 cdaq Run 49943: lh2,SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87959 07/25/04 23:07 cseely updated SOS and HMS thresholds
87958 07/25/04 22:58 cseely Hall A doing a linearity test. should take: '20 minutes'
87957 07/25/04 22:46 cdaq Run 49942: lh2,SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87956 07/25/04 22:32 clasie S1X and S1Y scalers
87955 07/25/04 22:21 cseely HMS set to correct momentum
87954 07/25/04 22:01 cdaq Run 49941: lh2,SOS P=-1.19th= 27.76, HMS P=2.793, th=10.60
87953 07/25/04 21:53 okayasu Target chaged
87952 07/25/04 21:53 cdaq Run 49940: lh2,SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87951 07/25/04 21:43 cdaq Run 49939: dummy,SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87950 07/25/04 21:24 cseely checked S1X and S2Y signals - look good
87949 07/25/04 21:23 cdaq Run 49938: dummy,SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87948 07/25/04 21:15 okayasu Target change
87947 07/25/04 21:11 cdaq Run 49937: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87946 07/25/04 21:03 cdaq Run 49936: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87945 07/25/04 20:41 cdaq Run 49935: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87944 07/25/04 20:25 cdaq Run 49934: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87943 07/25/04 20:07 cdaq Run 49933: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87942 07/25/04 19:36 cdaq Run 49932: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87941 07/25/04 19:06 cdaq Run 49931: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87940 07/25/04 18:37 cdaq Run 49930: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=10.60
87939 07/25/04 18:30 cdaq Run 49929: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=13.60
87938 07/25/04 17:55 cdaq Run 49928: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=13.60
87937 07/25/04 17:25 cdaq Run 49927: lh2 SOS P=-1.19th= 27.76, HMS P=2.2793, th=13.60
87936 07/25/04 17:24 okayasu Target change
87935 07/25/04 16:44 cdaq Run 49926: dummy, SOS P=-1.19th= 27.76, HMS P=2.2793, th=13.60
87934 07/25/04 16:19 kramerk Shift Summary
87933 07/25/04 16:19 cdaq Beam Time Accounting
87932 07/25/04 15:30 cdaq Run 49925: Al Dummy, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87931 07/25/04 15:16 cdaq Run 49924: Al dummy, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87930 07/25/04 14:53 cdaq Run 49923: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87929 07/25/04 14:37 R.Asaturyan target check list
87928 07/25/04 14:13 cdaq Run 49922: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87927 07/25/04 13:27 cdaq Run 49921: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87926 07/25/04 12:41 cdaq Run 49920: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87925 07/25/04 08:23 cseely target checklist
87924 07/25/04 08:00 cdaq Beam Time Accounting
87923 07/25/04 08:00 ent shift summary
87922 07/25/04 03:05 cseely nope. injector problem again.
87921 07/25/04 02:47 cseely target screen shot. set for 70 uA on LH2
87920 07/25/04 02:43 cseely changing target to LH2, beam coming back.
87919 07/25/04 01:53 cseely HMS drift chambers tripped. bringing them back up now.
87918 07/25/04 00:18 cseely moving to empty target till beam comes back
87917 07/25/04 00:08 cseely target checklist
87916 07/25/04 00:05 cseely SOS magnet screenshot
87915 07/25/04 00:03 cdaq Beam Time Accounting
Saturday
87914 07/24/04 23:46 cseely swing shift summary
87913 07/24/04 23:04 cdaq Beam Time Accounting
87912 07/24/04 22:52 cseely sSCIN scaler counts low...trying to find out why
87911 07/24/04 22:36 cdaq Run 49919: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87910 07/24/04 22:00 cdaq Run 49918: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87909 07/24/04 21:58 cdaq Run 49917: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=13.60
87908 07/24/04 21:55 okayasu Target changed.
87907 07/24/04 21:54 cdaq Run 49916: LH2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87906 07/24/04 21:15 cseely bpms/bcms screens
87905 07/24/04 21:12 cdaq Run 49915: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87904 07/24/04 21:03 okayasu Taregt IOC rebooted.
87903 07/24/04 21:01 cseely SOS magnet screenshot
87902 07/24/04 21:01 cseely rebooted cryotarget IOC...recovered fine
87901 07/24/04 20:29 cdaq Run 49914: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87900 07/24/04 20:28 okayasu Run stop.
87899 07/24/04 20:28 cseely hall A half wave plate being inserted. stopped run 49913
87898 07/24/04 20:06 cdaq Run 49913: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87897 07/24/04 19:21 cdaq Run 49912: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87896 07/24/04 19:17 cdaq Run 49911: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87895 07/24/04 18:55 cdaq Run 49910: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87894 07/24/04 18:48 okayasu Target IOC reboot
87893 07/24/04 18:44 cseely
87892 07/24/04 18:35 cdaq Run 49909: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87891 07/24/04 18:16 cdaq Run 49908: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87890 07/24/04 18:08 cdaq Run 49907: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87889 07/24/04 18:04 cseely changed SOS to 3/4 trigger (from ELREAL)
87888 07/24/04 18:03 cdaq Run 49906: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87887 07/24/04 18:02 okayasu HV monitor screenshots
87886 07/24/04 17:41 cseely SOS magnet screenshot
87885 07/24/04 17:31 cdaq Run 49905: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87884 07/24/04 16:49 cseely SOS magnet screenshot
87883 07/24/04 16:46 cdaq Run 49904: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87882 07/24/04 16:28 okayasu Target check list
87881 07/24/04 16:06 cdaq Run 49903: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87880 07/24/04 15:57 kramerk Shift Summary
87879 07/24/04 15:31 cdaq Run 49902: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87878 07/24/04 14:46 tigran Hall A inserts half wave plate.
87877 07/24/04 14:44 cdaq Run 49901: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87876 07/24/04 14:12 cdaq Run 49900: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87875 07/24/04 13:26 cdaq Run 49899: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87874 07/24/04 12:39 cdaq Run 49898: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87873 07/24/04 11:52 cdaq Run 49897: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87872 07/24/04 11:07 R.Asaturyan Target
87871 07/24/04 11:06 cdaq Run 49896: 6% Cu, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87870 07/24/04 10:25 cdaq Run 49895: LD2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87869 07/24/04 09:39 cdaq Run 49894: LD2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87868 07/24/04 08:50 cdaq Run 49893: LD2, SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87867 07/24/04 08:02 ent shift summary
87866 07/24/04 08:02 cdaq Beam Time Accounting
87865 07/24/04 07:53 cseely Loop2 un-parked.
87864 07/24/04 07:46 cdaq Run 49892: Al dummy SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87863 07/24/04 07:43 cseely target change: from LH2 to Al dummy
87862 07/24/04 06:51 cdaq Run 49891: LH2 SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87861 07/24/04 06:01 cdaq Run 49890: LH2 SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87860 07/24/04 05:20 cdaq Run 49889: LH2 SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87859 07/24/04 05:06 cseely cryotarget IOC reboot - smooth recovery
87858 07/24/04 04:37 cdaq Run 49888: 2%C SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87857 07/24/04 04:23 cseely HMS dipole tripped during run 49886, resetting.
87856 07/24/04 04:16 cdaq Run 49887: 2%C SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87855 07/24/04 03:47 cseely rebooted cryotarget IOC...recovered fine
87854 07/24/04 03:26 cdaq Run 49886: 2%C SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87853 07/24/04 01:56 cseely checked fridges in gas shed: temps and flows normal, fridge doors closed tight.
87852 07/24/04 01:45 cdaq Run 49885: 2%C SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87851 07/24/04 01:13 cdaq Run 49884: 2%C SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87850 07/24/04 01:03 ent runs 49882+49883 2% carbon
87849 07/24/04 00:49 cdaq Run 49883: LH2 SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87848 07/24/04 00:47 cdaq Beam Time Accounting
87847 07/24/04 00:22 cdaq Run 49882: LH2 SOS P=-0.73 th= 50.76, HMS P=3.187, th=10.60
87846 07/24/04 00:15 cdaq Run 49881: LH2 SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
87845 07/24/04 00:08 cseely target checklist
87844 07/24/04 00:05 cdaq Run 49880: 3% C SOS P=-1.3 th= 50.76, HMS P=-1.3, th=10.6
87843 07/24/04 00:02 cdaq Run 49879: LH2 SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
Friday
87842 07/23/04 23:42 cseely swing shift summary
87841 07/23/04 23:12 cdaq Run 49878: Al dummy SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
87840 07/23/04 22:58 clasie Target: move to dummy
87839 07/23/04 22:50 Ferrer BPM/BCM Screens
87838 07/23/04 22:33 cdaq Run 49877: LH2 SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
87837 07/23/04 21:53 cdaq Run 49876: LH2 SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
87836 07/23/04 21:30 cdaq Run 49875: LH2 SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
87835 07/23/04 21:27 cdaq Run 49874: LH2 SOS P=-1.3 th= 50, HMS P=-1.3, th=22.15
87834 07/23/04 21:25 cdaq Run 49873: LH2 SOS P=-1.3 th= 25, HMS P=-1.3, th=25
87833 07/23/04 20:30 Xin Unparked the LH2 target and moved the target from 10% carbon to LH2.
87832 07/23/04 20:29 Xin Changed target from 3% carbon to 10% carbon
87831 07/23/04 20:28 Xin Change targe from empty to 3% carbon
87830 07/23/04 20:09 cseely beam position moved -1mm in Y
87829 07/23/04 20:09 cdaq Run 49872: Carbon SOS P=-1.3 th= 25, HMS P=-1.3, th=25
87828 07/23/04 20:07 cdaq Run 49871: Carbon SOS P=-1.3 th= 25, HMS P=-1.3, th=25
87827 07/23/04 19:33 cdaq Run 49869: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87826 07/23/04 19:05 cdaq Run 49868: Gold, SOS P=-1.3 th= 25, HMS P=-1.3, th=25HMS trigger elreal SOS trigger = elreal
87825 07/23/04 18:30 cseely c_physics.f change
87824 07/23/04 16:18 cdaq Beam Time Accounting
87823 07/23/04 16:17 clasie Day shift summary
87822 07/23/04 16:12 Xin Target checklist
87821 07/23/04 15:40 clasie accelerator update
87820 07/23/04 14:16 clasie LN2 manfacturing plant has broken down
87819 07/23/04 12:18 clasie accelerator update
87818 07/23/04 11:26 clasie SOS camera has been replaced
87817 07/23/04 10:40 clasie SOS camera change
87816 07/23/04 10:17 Liang Target moved
87815 07/23/04 10:11 clasie beam spot change
87814 07/23/04 09:33 clasie HMS Q2 max current set alarm
87813 07/23/04 09:02 clasie SOS floor angle camera
87812 07/23/04 08:52 Liang Target checklist of day shift
87811 07/23/04 08:04 cdaq Beam Time Accounting
87810 07/23/04 08:04 horn Owl Shift Summary
87809 07/23/04 06:14 gaskell Recovery from CHL trip - no beam for a while
87808 07/23/04 04:12 gaskell CHL trip
87807 07/23/04 04:11 cdaq Run 49867: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87806 07/23/04 03:32 cdaq Run 49866: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87805 07/23/04 02:51 cdaq Run 49865: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87804 07/23/04 02:10 cdaq Run 49864: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87803 07/23/04 01:42 cdaq Run 49863: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87802 07/23/04 01:16 cdaq Run 49862: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87801 07/23/04 00:54 cdaq Run 49861: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87800 07/23/04 00:39 horn Beam position adjustment
87799 07/23/04 00:35 horn Target: Shift Checklist
87798 07/23/04 00:30 cdaq Run 49860: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87797 07/23/04 00:12 cdaq Beam Time Accounting
87796 07/23/04 00:12 clasie swing shift summary
Thursday
87795 07/22/04 23:58 cdaq Run 49859: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87794 07/22/04 23:31 cdaq Run 49858: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87793 07/22/04 23:18 Bosted Target computer reboot
87792 07/22/04 23:04 cdaq Run 49857: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87791 07/22/04 22:31 cdaq Run 49856: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87790 07/22/04 21:58 cdaq Run 49855: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87789 07/22/04 21:23 cdaq Run 49854: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87788 07/22/04 20:57 clasie VESDA alarms
87787 07/22/04 20:52 cdaq Run 49853: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87786 07/22/04 20:32 Ferrer Equipment Checklist
87785 07/22/04 20:22 cdaq Run 49852: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87784 07/22/04 20:08 cdaq Run 49851: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87783 07/22/04 19:39 clasie No beam for a half hour
87782 07/22/04 19:34 Ferrer BPM//BCM screenshot
87781 07/22/04 19:32 cdaq Run 49850: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87780 07/22/04 19:02 M Jones Hall C beam energy measurement
87779 07/22/04 19:00 cdaq Run 49849: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87778 07/22/04 18:47 Bosted Target reboot
87777 07/22/04 18:33 cdaq Run 49848: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87775 07/22/04 18:03 cdaq Run 49847: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87774 07/22/04 17:48 Bosted Target reboot, slight alarm level change
87773 07/22/04 17:42 cdaq Run 49846: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87772 07/22/04 17:20 clasie Hall A requests that the half waveplate be inserted
87771 07/22/04 17:16 cdaq Run 49845: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87770 07/22/04 17:02 Bosted Target Screen Grab
87769 07/22/04 17:01 clasie Beam taken our of forced gain mode
87768 07/22/04 16:58 cdaq Run 49844: Gold, SOS P=-0.91 th= 55.87, HMS P=3.857, th=10.5
87767 07/22/04 16:57 Bosted Target Screen Grab
87766 07/22/04 16:51 Bosted Put in 6% Gold target
87764 07/22/04 16:11 cdaq Beam Time Accounting
87763 07/22/04 16:03 Keppel day shift summary
87762 07/22/04 15:55 Keppel SOS magnet trip
87761 07/22/04 14:52 tigran Daq problems solved.
87760 07/22/04 14:09 Keppel dipole trip
87759 07/22/04 13:20 cdaq Run 49843: Gold, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87757 07/22/04 12:50 tigran Spectrometer momentum.
87756 07/22/04 12:14 tigran Spectrometer rotation.
87755 07/22/04 12:05 Keppel ESR crash
87754 07/22/04 11:51 smith, meeki target warmup complete following esr crash
87753 07/22/04 08:29 cdaq Run 49841: Gold, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87752 07/22/04 08:21 Xin target checklist
87751 07/22/04 08:03 cdaq Beam Time Accounting
87750 07/22/04 07:58 horn Target: Shift screen
87749 07/22/04 07:54 gaskell Owl Shift Summary
87748 07/22/04 07:54 cdaq Run 49840: 6%Au, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87747 07/22/04 07:53 horn Target: Change of target
87746 07/22/04 07:29 horn Target: IOC Reboot
87745 07/22/04 07:22 cdaq Run 49839: 6%Cu, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87744 07/22/04 06:48 cdaq Run 49838: 6%Cu, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87743 07/22/04 06:45 gaskell HMS drift chambers tripped
87742 07/22/04 06:24 cdaq Run 49837: 6%Cu, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87741 07/22/04 06:00 gaskell Run 49836 really Copper
87740 07/22/04 05:58 gaskell Changed to Q2=2.15 setting
87739 07/22/04 05:53 cdaq Run 49836: 3%C, SOS P=-1.73 th= 28.85, HMS P=3.187, th=13.45
87738 07/22/04 05:53 horn Target: Change of target material
87737 07/22/04 05:35 akihiko BPM & BCM
87736 07/22/04 05:15 cdaq Run 49835: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87735 07/22/04 04:42 cdaq Run 49834: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87734 07/22/04 04:11 cdaq Run 49833: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87733 07/22/04 03:40 cdaq Run 49832: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87732 07/22/04 03:10 gaskell target changed to LH2
87731 07/22/04 03:09 cdaq Run 49831: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87730 07/22/04 02:34 cdaq Run 49830: Dummy, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87729 07/22/04 02:04 gaskell rotated HMS to 10.55 degrees
87728 07/22/04 02:03 cdaq Run 49829: Dummy, SOS P=-1.43 th= 37.76, HMS P=3.418, th=10.55
87727 07/22/04 01:43 cdaq Run 49828: Dummy, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87726 07/22/04 00:50 cdaq Run 49827: Dummy, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87725 07/22/04 00:50 horn Target: Change of target
87724 07/22/04 00:39 cdaq Run 49826: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87723 07/22/04 00:11 gaskell Half wave plate will be going in
87722 07/22/04 00:08 gaskell beam position adjustment
87721 07/22/04 00:07 cdaq Run 49825: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87720 07/22/04 00:01 cdaq Beam Time Accounting
87719 07/22/04 00:01 gabriel shift summary (cont.)
Wednesday
87718 07/21/04 23:59 Bosted Target Screen
87717 07/21/04 23:33 cdaq Run 49824: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87716 07/21/04 23:16 cdaq Run 49823: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87715 07/21/04 22:40 cdaq Run 49822: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87714 07/21/04 21:56 cdaq Run 49821: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87713 07/21/04 21:33 Bosted Changed visual scalar for coincidences
87712 07/21/04 21:30 Bosted HMS angle changed to 15.74
87711 07/21/04 21:29 Bosted Target changed to H2
87710 07/21/04 21:19 cdaq Run 49820: LH2, SOS P=-1.43 th= 37.76, HMS P=3.418, th=15.74
87709 07/21/04 20:41 cdaq Run 49819: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87708 07/21/04 20:09 cdaq Run 49818: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87707 07/21/04 17:14 gabriel shift summary
87706 07/21/04 16:30 cdaq Run 49817: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87705 07/21/04 16:17 adaniel change of helium bottle
87704 07/21/04 16:01 R.Asaturyan day shift summary
87703 07/21/04 16:01 cdaq Beam Time Accounting
87702 07/21/04 15:54 cdaq Run 49816: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87701 07/21/04 15:42 okayasu Screen shot
87700 07/21/04 15:22 cdaq Run 49815: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87699 07/21/04 14:49 cdaq Run 49814: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87698 07/21/04 14:32 smithg Target: Scattering chamber vacuum
87697 07/21/04 14:17 cdaq Run 49813: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87696 07/21/04 13:43 cdaq Run 49812: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87695 07/21/04 13:19 okayasu Data taking started
87694 07/21/04 13:13 cdaq Run 49811: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87693 07/21/04 12:27 okayasu Cryotarget alarm
87692 07/21/04 12:26 Lassiter Q1 Main coil Quench
87691 07/21/04 11:40 okayasu Target change.
87690 07/21/04 10:54 okayasu Screen shots.
87689 07/21/04 09:55 okayasu Q1 down
87688 07/21/04 09:29 okayasu Target changing
87687 07/21/04 09:14 cdaq Run 49810: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87686 07/21/04 08:58 okayasu Beam stop
87685 07/21/04 08:57 cdaq Run 49809: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87684 07/21/04 08:22 okayasu Target GUI monitor.
87683 07/21/04 08:20 cdaq Run 49808: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87682 07/21/04 08:20 okayasu HMS chamber tripped.
87681 07/21/04 08:15 cdaq Run 49807: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87680 07/21/04 08:02 cdaq Beam Time Accounting
87679 07/21/04 07:46 gaskell Owl Shift Summary
87678 07/21/04 07:43 cdaq Run 49806: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87677 07/21/04 07:15 cdaq Run 49805: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87676 07/21/04 06:52 aamer checklist snapshots
87675 07/21/04 06:41 gaskell updated sos thresholds
87674 07/21/04 06:40 cdaq Run 49804: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87673 07/21/04 06:08 cdaq Run 49803: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87672 07/21/04 06:07 horn Target: IOC reboot
87671 07/21/04 05:34 cdaq Run 49802: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87670 07/21/04 05:00 cdaq Run 49801: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87669 07/21/04 04:24 cdaq Run 49800: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87668 07/21/04 03:48 cdaq Run 49799: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87667 07/21/04 03:15 cdaq Run 49798: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87666 07/21/04 02:43 cdaq Run 49797: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87665 07/21/04 02:26 gaskell hall a inserts half wave plate
87664 07/21/04 02:07 gaskell updated sos thresholds
87663 07/21/04 02:06 cdaq Run 49796: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87662 07/21/04 01:54 cdaq Run 49795: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87661 07/21/04 01:20 cdaq Run 49794: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87660 07/21/04 00:46 cdaq Run 49793: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87659 07/21/04 00:14 gaskell Q1 tripped at end of run 49792
87658 07/21/04 00:05 cdaq Run 49792: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87657 07/21/04 00:02 cdaq Beam Time Accounting
Tuesday
87656 07/20/04 23:59 gabriel shift summary
87655 07/20/04 23:16 cdaq Run 49791: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87654 07/20/04 22:17 cdaq Run 49790: Gold, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87653 07/20/04 22:16 Liang Target moved
87652 07/20/04 21:52 cdaq Run 49789: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87651 07/20/04 21:24 cdaq Run 49788: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87650 07/20/04 20:51 cdaq Run 49787: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87649 07/20/04 20:17 cdaq Run 49786: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87648 07/20/04 19:45 cdaq Run 49785: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87647 07/20/04 19:10 cdaq Run 49784: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87646 07/20/04 18:46 clasie BCM screen
87645 07/20/04 18:34 cdaq Run 49783: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87644 07/20/04 17:31 cdaq Run 49782: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87643 07/20/04 17:02 cdaq Run 49781: Copper, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87642 07/20/04 17:01 Liang Target moved
87641 07/20/04 16:51 R.Asaturyan Day shift summary
87640 07/20/04 16:37 cdaq Run 49780: Carbon, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87639 07/20/04 16:29 cseely changed HV on bad SOS calorimeter channel
87638 07/20/04 16:11 cdaq Run 49779: Carbon, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87637 07/20/04 16:04 Liang Target checklist
87636 07/20/04 16:03 cdaq Run 49778: Carbon, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87635 07/20/04 16:00 cdaq Beam Time Accounting
87634 07/20/04 15:47 cseely missing channel in SOS calorimeter
87633 07/20/04 15:28 cdaq Run 49777: Carbon, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87632 07/20/04 15:12 Miyoshi cryotarget IOC reboot
87631 07/20/04 14:58 cdaq Run 49776: Carbon, SOS P=-1.43 th= 37.76, HMS P=3.418, th=12.74
87630 07/20/04 14:56 Miyoshi changing LD2 to 3%carbon(2%@MCCscreen)
87629 07/20/04 14:21 cdaq Run 49775: LD2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87628 07/20/04 14:21 Miyoshi Target is LD2 (from run 49774)
87627 07/20/04 13:59 Miyoshi Target checklist - day shift
87626 07/20/04 13:47 cdaq Run 49774: LD2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87625 07/20/04 13:08 cdaq Run 49773: Dummy, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87619 07/20/04 10:11 Miyoshi screen shot of graph for target
87615 07/20/04 09:39 Miyoshi Beam off until 2pm
87614 07/20/04 09:07 gaskell new sos angle marker straightened
87613 07/20/04 08:47 horn/gaskell Scattering chamber vacuum
87612 07/20/04 08:34 cdaq Beam Time Accounting
87611 07/20/04 00:09 cdaq Beam Time Accounting
Monday
87610 07/19/04 21:08 gabriel shift summary
87609 07/19/04 16:02 R.Asaturyan Day shift summary
87608 07/19/04 16:01 cdaq Beam Time Accounting
87607 07/19/04 14:11 Miyoshi Target checklist day shift
87604 07/19/04 12:39 Lassiter HMS Q2 repairs
87603 07/19/04 12:29 Miyoshi dummy target
87601 07/19/04 10:03 Miyoshi HV screen
87600 07/19/04 09:28 Fowler Rebooting Quad PC's
87599 07/19/04 09:15 cdaq Run 49772: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87598 07/19/04 09:00 cdaq Run 49771: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87597 07/19/04 08:12 cdaq Run 49770: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87596 07/19/04 08:11 cdaq Beam Time Accounting
87595 07/19/04 07:57 cseely MCC called to inform us that hall A has requested that the half wave plate be inserted
87594 07/19/04 07:52 cdaq Beam Time Accounting
87593 07/19/04 07:52 aamer owl summary shift
87592 07/19/04 07:22 cseely Q3 PC problem. caused trip, ramping down
87591 07/19/04 07:16 cdaq Run 49769: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87590 07/19/04 06:15 cdaq Run 49768: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87589 07/19/04 06:06 cseely cryotarget IOC reboot
87588 07/19/04 05:44 cdaq Run 49767: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87587 07/19/04 05:13 cseely status of target alarms after last IOC reboot
87586 07/19/04 05:12 cdaq Run 49766: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87585 07/19/04 04:57 cseely followup to H(e,e'p) data vs. monte carlo comparisons
87584 07/19/04 04:41 cdaq Run 49765: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87583 07/19/04 04:35 cseely Q2 trip note
87582 07/19/04 04:25 aamer Q2 tripped
87581 07/19/04 04:21 cseely Q2 tripped. PC frozen, so rebooting it.
87580 07/19/04 04:18 cseely rebooted cryotarget IOC
87579 07/19/04 04:10 cdaq Run 49764: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87578 07/19/04 03:39 cdaq Run 49763: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87577 07/19/04 03:37 cseely H(e,e'p) data vs. monte carlo comparisons (resubmission of 87572, but with a title)
87576 07/19/04 03:09 cdaq Run 49762: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87575 07/19/04 02:38 cdaq Run 49761: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87574 07/19/04 02:16 cseely Q2 tripped again. trim coil quench. restarting it.
87573 07/19/04 02:10 cdaq Run 49760: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87572 07/19/04 02:04
87571 07/19/04 01:39 cdaq Run 49759: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87570 07/19/04 01:28 cdaq Run 49758: 6%Copper, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87569 07/19/04 01:25 cseely changing to Cu(6%) target from C(3%) target
87568 07/19/04 01:25 cseely changing to Cu(6%) target from C(3%) target
87567 07/19/04 01:15 cdaq Run 49757: 3%Carbon, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87566 07/19/04 00:24 cdaq Run 49756: 3%Carbon, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87565 07/19/04 00:19 akopper swing shift summary
87564 07/19/04 00:14 cseely target checklist - owl shift
87563 07/19/04 00:12 cseely unparked Loop 1
87562 07/19/04 00:07 cdaq Beam Time Accounting
Sunday
87561 07/18/04 23:49 cdaq Run 49755: 3%Carbon, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87560 07/18/04 23:18 cdaq Run 49754: 3%Carbon, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87559 07/18/04 23:02 Liang Target checklist
87558 07/18/04 23:01 Liang Target checklist
87557 07/18/04 22:57 cdaq Run 49753: 3%Carbon, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87556 07/18/04 22:56 Liang Target Moved
87555 07/18/04 22:36 cdaq Run 49752: LD2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87554 07/18/04 22:14 cdaq Run 49751: LD2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87553 07/18/04 21:01 cdaq Run 49750: LD2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87552 07/18/04 20:32 Liang Target moved
87551 07/18/04 20:28 cdaq Run 49749: LD2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87550 07/18/04 20:01 cdaq Run 49748: Dummy, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87549 07/18/04 19:44 Liang Move target
87548 07/18/04 19:39 cdaq Run 49747: Dummy, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87547 07/18/04 19:28 akopper raster problems -- false alarm
87546 07/18/04 19:07 cdaq Run 49746: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87545 07/18/04 18:55 cdaq Run 49745: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87544 07/18/04 18:49 akopper raster is too big and we can't get it smaller
87543 07/18/04 18:05 cdaq Run 49744: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87542 07/18/04 18:02 cdaq Run 49743: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87541 07/18/04 17:44 cdaq Run 49742: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87540 07/18/04 17:19 akopper SOS cuurent settings resolved
87539 07/18/04 17:06 akopper SOS current different
87538 07/18/04 16:21 Bosted Day shift summary
87537 07/18/04 16:17 cdaq Beam Time Accounting
87536 07/18/04 15:23 Bosted Problem setting Q3
87535 07/18/04 15:19 Bosted HMS dipole problems
87534 07/18/04 15:13 Bosted SOS Delta Scan and Sieve slit running
87533 07/18/04 14:35 cdaq Run 49741: LH2, SOS P=-1.43 th= 37.76, HMS P=-3.418, th=12.74
87532 07/18/04 14:32 yuan Target change from 3% Carbon to LH2
87531 07/18/04 14:14 cdaq Run 49740: LH2 - SOS Only. SOS P=-1.43 theta = 37.76
87530 07/18/04 14:14 yuan Target change from LH2 to 3% Carbon
87529 07/18/04 13:49 cdaq Run 49739: LH2 - SOS Only Delta scan. SOS P=-1.43 theta = 51.78
87528 07/18/04 13:33 cdaq Run 49738: LH2 - SOS Only Delta scan. SOS P=-1.43 theta = 53.66
87527 07/18/04 13:19 cdaq Run 49737: LH2 - SOS Only Delta scan. SOS P=-1.43 theta = 55.68
87526 07/18/04 13:01 cdaq Run 49736: LH2 - SOS Only Delta scan. SOS P=-1.43 theta = 57.9
87525 07/18/04 12:44 cdaq Run 49735: LH2 - SOS Only Delta scan. SOS P=-1.43 theta = 60.12
87524 07/18/04 12:20 cdaq Run 49734: LH2 - SOS Only Delta scan. SOS P=-1.43 theta = 62.58
87523 07/18/04 12:05 cdaq Run 49733: LH2 - SOS Only sieve slit run. SOS P=-1.43 theta = 60.22
87522 07/18/04 11:46 yuan Target change from Dummy to LH2
87521 07/18/04 11:27 cdaq Run 49732: LH2 - SOS Only sieve slit run.
87520 07/18/04 11:25 cdaq Run 49731: LH2 - SOS Only sieve slit run.
87519 07/18/04 10:09 yuan Target change from LH2 to Al Dummy
87518 07/18/04 10:06 cdaq Run 49730: Al. Dummy - HMS P=3.857 theta =13.545
87517 07/18/04 08:51 cdaq Run 49729: LH2 - HMS P=3.857 theta =13.545
87516 07/18/04 08:24 yuan Target checklist
87515 07/18/04 08:16 cdaq Run 49728: LH2 - HMS P=3.857 theta =13.545
87514 07/18/04 08:02 cdaq Beam Time Accounting
87513 07/18/04 07:40 cdaq Run 49727: LH2 - HMS P=3.857 theta =13.545
87512 07/18/04 07:30 clasie QE measurement
87511 07/18/04 07:16 clasie MCC: Half wave plate is being moved out for hall A
87510 07/18/04 06:56 cdaq Run 49726: LH2 - HMS P=3.857 theta =13.545
87509 07/18/04 06:14 ent HMS Rotation: careful!
87508 07/18/04 06:00 cdaq Run 49725: LH2 - HMS P=3.857 theta =13.545
87507 07/18/04 05:58 clasie HMS DC tripped again without beam
87506 07/18/04 05:18 cdaq Run 49724: LH2 - HMS P=3.857 theta =13.545
87505 07/18/04 05:16 clasie Target: GUI Beam current
87504 07/18/04 04:55 cdaq Run 49723: LH2 - HMS P=3.857 theta =13.545
87503 07/18/04 04:22 ent Run 49722 also LH2, 13.545 degrees
87502 07/18/04 04:15 ent Run 49721 LH2, 13.545 degrees
87501 07/18/04 04:11 cdaq Run 49722: 6% Cu - HMS P=3.857 theta =10.545
87500 07/18/04 03:16 ent Q2 + rotation fixed
87499 07/18/04 03:15 cdaq Run 49721: 6% Cu - HMS P=3.857 theta =10.545
87498 07/18/04 02:29 clasie HMS wire chamber trip with no beam
87497 07/18/04 00:39 ent Q2 trim coil problem
87496 07/18/04 00:34 cdaq Beam Time Accounting
87495 07/18/04 00:10 clasie Target: checklist
87494 07/18/04 00:01 cdaq Run 49720: 6% Cu - HMS P=3.857 theta =10.545
Saturday
87493 07/17/04 23:55 cseely swing shift summary
87492 07/17/04 23:53 okayasu Q2 trip
87491 07/17/04 23:33 okayasu Q2 trip again.
87490 07/17/04 23:22 cdaq Run 49719: 6% Cu - HMS P=3.857 theta =10.545
87489 07/17/04 23:13 okayasu Run start
87488 07/17/04 23:12 cseely back in business
87487 07/17/04 23:05 okayasu SOS & HMS detectors' HV status
87486 07/17/04 22:14 okayasu Chaging target
87485 07/17/04 20:38 cseely followup, and correction to entry 87479
87484 07/17/04 20:06 cseely scal and hcal calibration parameters updated from run 49511
87483 07/17/04 20:06 cdaq Run 49718: 6% Cu - HMS P=3.857 theta =10.545
87482 07/17/04 20:05 okayasu Q2 trip trouble recovered.
87481 07/17/04 20:04 cdaq Run 49717: 6% Cu - HMS P=3.857 theta =10.545
87480 07/17/04 19:51
87479 07/17/04 19:47 cseely rotation and Q2 problems update
87478 07/17/04 19:24 okayasu Q2 trouble.
87477 07/17/04 19:14 okayasu Q2 trip again.
87476 07/17/04 19:11 okayasu Q2 alarm again.
87475 07/17/04 19:10 okayasu Q2 alarm again.
87474 07/17/04 19:04 okayasu Cryotarget alarm.
87473 07/17/04 18:58 okayasu Q2 trip was recovered.
87472 07/17/04 18:56 cdaq Run 49716: 6% Cu - HMS P=3.857 theta =10.545
87471 07/17/04 18:25 okayasu HMS Q2 tripped.
87470 07/17/04 18:17 cseely hcal.param set back to old values
87469 07/17/04 18:02 cdaq Run 49715: 6% Cu - HMS P=3.857 theta =10.545
87468 07/17/04 17:30 cdaq Run 49714: 6% Cu - HMS P=3.857 theta =10.545
87467 07/17/04 17:28 cseely hcal and scal calibrations performed using run 49511 (both arms: e-, 25 deg., -1.3 GeV)
87466 07/17/04 17:23 cdaq Run 49713: 6% Cu - HMS P=3.857 theta =10.545
87465 07/17/04 16:56 okayasu Caution !!!
87464 07/17/04 16:36 cdaq Run 49712: 6% Cu - HMS P=3.857 theta =10.545
87463 07/17/04 16:29 okayasu Target Changed from LH2 to Cu.
87462 07/17/04 16:09 ddutta Day shift summary
87461 07/17/04 16:09 ddutta Day shift summary
87460 07/17/04 16:01 cdaq Beam Time Accounting
87459 07/17/04 15:58 yuan Target checklist
87458 07/17/04 15:53 ddutta Q2 tripped
87457 07/17/04 15:50 cdaq Run 49711: 6% Cu - HMS P=3.857 theta =10.545
87455 07/17/04 15:42 yuan Target change to LH2
87454 07/17/04 15:09 cdaq Run 49710: 6% Cu - HMS P=3.857 theta =10.545
87453 07/17/04 14:36 cdaq Run 49709: 6% Cu - HMS P=3.857 theta =10.545
87452 07/17/04 14:15 tigran Changed helium bottle.
87451 07/17/04 14:04 cdaq Run 49708: 6% Cu - HMS P=3.857 theta =10.545
87450 07/17/04 13:50 ddutta Dipole finally back in business
87449 07/17/04 13:33 cdaq Run 49707: 6% Cu - HMS P=3.857 theta =10.545
87448 07/17/04 11:38 yuan IOC reboot
87447 07/17/04 11:30 tigran Hall A half wave plate in.
87446 07/17/04 10:52 yuan IOC reboot
87445 07/17/04 10:52 ddutta Dipole trips without alarming
87444 07/17/04 10:11 cdaq Run 49706: 6% Cu - HMS P=3.857 theta =10.545
87443 07/17/04 09:39 ddutta Q3 trips
87442 07/17/04 09:37 cdaq Run 49705: 6% Cu - HMS P=3.857 theta =10.545
87441 07/17/04 08:50 cdaq Run 49704: 6% Cu - HMS P=3.857 theta =10.545
87440 07/17/04 08:24 yuan Target checklist
87439 07/17/04 08:19 cdaq Run 49703: 6% Cu - HMS P=3.857 theta =10.545
87438 07/17/04 08:01 cdaq Beam Time Accounting
87437 07/17/04 07:57 cdaq Run 49702: 6% Cu - HMS P=3.857 theta =10.545
87436 07/17/04 06:44 cdaq Run 49701: 6% Cu - HMS P=3.857 theta =10.545
87435 07/17/04 06:41 cdaq Run 49700: 6% Cu - HMS P=3.857 theta =10.545
87434 07/17/04 04:43 cdaq Run 49699: 6% Cu - HMS P=3.857 theta =10.545
87433 07/17/04 03:51 cdaq Run 49698: 6% Cu - HMS P=3.857 theta =10.545
87432 07/17/04 03:10 clasie HMS wire chamber trip
87431 07/17/04 03:06 cdaq Run 49697: 6% Cu - HMS P=3.857 theta =10.545
87430 07/17/04 02:55 cdaq Run 49696: 6% Cu - HMS P=3.857 theta =10.545
87429 07/17/04 02:36 clasie Target: IOC reboot
87428 07/17/04 02:11 cdaq Run 49695: 6% Cu - HMS P=3.857 theta =10.545
87427 07/17/04 01:32 cdaq Run 49694: 6% Cu - HMS P=3.857 theta =10.545
87426 07/17/04 00:57 clasie Target: ioc reboot
87425 07/17/04 00:50 cdaq Run 49693: 6% Cu - HMS P=3.857 theta =10.545
87424 07/17/04 00:27 clasie Target: checklist
87423 07/17/04 00:18 cdaq Run 49692: 6% Cu - HMS P=3.857 theta =10.545
87422 07/17/04 00:01 cdaq Beam Time Accounting
Friday
87421 07/16/04 23:52 Huber Swing shift summary
87420 07/16/04 23:40 cdaq Run 49691: 6% Cu - HMS P=3.857 theta =10.545
87419 07/16/04 23:10 cdaq Run 49690: 6% Cu - HMS P=3.857 theta =10.545
87418 07/16/04 22:51 cdaq Run 49689: 6% Cu - HMS P=3.857 theta =10.545
87417 07/16/04 22:07 cdaq Run 49688: 6% Cu - HMS P=3.857 theta =10.545
87416 07/16/04 21:29 clasie Scan of shift checklist
87415 07/16/04 21:11 cdaq Run 49687: 6% Cu - HMS P=3.857 theta =10.545
87414 07/16/04 21:05 cdaq Run 49686: 6% Cu - HMS P=3.857 theta =10.545
87413 07/16/04 20:59 Huber HMS Dipole PC is frozen
87412 07/16/04 20:42 cseely target checklist
87411 07/16/04 20:39 cseely another cryotarget IOC reboot - recovered fine
87410 07/16/04 20:36 cdaq Run 49685: 6% Cu - HMS P=3.857 theta =10.545
87409 07/16/04 20:08 cdaq Run 49684: 6% Cu - HMS P=3.857 theta =10.545
87408 07/16/04 19:31 cseely 'Hall Cam UP' went out while panning around the hall
87407 07/16/04 18:39 cseely ROOT trees hack in replay script
87406 07/16/04 18:32 cdaq Run 49683: 6% Cu - HMS P=3.857 theta =10.545
87405 07/16/04 18:03 cdaq Run 49682: 6% Cu - HMS P=3.857 theta =10.545
87404 07/16/04 17:27 mack BCM calibrations still stable
87403 07/16/04 17:13 cseely cdaq account: updated Analyzer from CVS (for ROOT TTree stuff), and remade Analyzer
87402 07/16/04 17:13 cseely cdaq account: updated Analyzer from CVS (for ROOT TTree stuff), and remade Analyzer
87401 07/16/04 16:08 cseely rebooted cryotarget IOC - no problems
87400 07/16/04 16:03 cdaq Beam Time Accounting
87399 07/16/04 15:52 ddutta Day Shift summary
87398 07/16/04 15:25 cseely attn. target operators: IOC reboot problem today
87397 07/16/04 15:18 cdaq Run 49681: 6% Cu - HMS P=3.857 theta =10.545
87396 07/16/04 14:56 yuan Target IOC reboot
87395 07/16/04 14:46 cdaq Run 49680: 6% Cu - HMS P=3.857 theta =10.545
87394 07/16/04 14:12 cdaq Run 49679: 6% Cu - HMS P=3.857 theta =10.545
87393 07/16/04 14:05 cdaq Run 49678: 6% Cu - HMS P=3.857 theta =10.545
87392 07/16/04 13:24 cdaq Run 49677: 6% Cu - HMS P=3.857 theta =10.545
87391 07/16/04 13:16 cdaq Run 49676: 6% Cu - HMS P=3.857 theta =10.545
87388 07/16/04 10:26 ddutta Q3 did not recover from the trip
87387 07/16/04 09:26 ddutta Q3 tripped
87386 07/16/04 09:03 cdaq Run 49675: 6% Cu - HMS P=3.857 theta =10.545
87385 07/16/04 08:56 yuan target condition
87384 07/16/04 08:32 cdaq Run 49674: 6% Cu - HMS P=3.857 theta =10.545
87383 07/16/04 08:01 cdaq Beam Time Accounting
87382 07/16/04 07:59 cdaq Run 49673: 6% Cu - HMS P=3.857 theta =10.545
87381 07/16/04 07:56 clasie owl shift summary
87380 07/16/04 07:50 R.Asaturyan Target
87379 07/16/04 07:31 cdaq Run 49672: 6% Cu - HMS P=3.857 theta =10.545
87378 07/16/04 07:12 clasie HMS Q1 is now on
87376 07/16/04 07:01 cdaq Run 49671: 6% Cu - HMS P=3.857 theta =10.545
87375 07/16/04 06:56 clasie HMS Q1 trip
87374 07/16/04 06:24 cdaq Run 49670: 6% Cu - HMS P=3.857 theta =10.545
87373 07/16/04 05:55 cdaq Run 49669: 6% Cu - HMS P=3.857 theta =10.545
87372 07/16/04 05:25 cdaq Run 49668: 6% Cu - HMS P=3.857 theta =10.545
87371 07/16/04 04:37 cdaq Run 49667: 6% Cu - HMS P=3.857 theta =10.545
87370 07/16/04 04:05 cdaq Run 49666: 6% Cu - HMS P=3.857 theta =10.545
87369 07/16/04 03:49 cdaq Run 49665: 6% Cu - HMS P=3.857 theta =10.545
87368 07/16/04 03:41 clasie MCC: RF zone trip
87367 07/16/04 03:18 Donal Shift check list
87366 07/16/04 03:13 cdaq Run 49664: 6% Cu - HMS P=3.857 theta =10.545
87365 07/16/04 02:41 cdaq Run 49663: 6% Cu - HMS P=3.857 theta =10.545
87364 07/16/04 02:27 cdaq Run 49662: 6% Cu - HMS P=3.857 theta =10.545
87363 07/16/04 02:24 clasie moller quad ioc was rebooted by request from MCC
87362 07/16/04 02:22 clasie cdaql3 froze and was rebooted at 12:50 am
87361 07/16/04 02:06 cdaq Beam Time Accounting
87360 07/16/04 02:00 cdaq Run 49661: 6% Cu - HMS P=3.857 theta =10.545
87359 07/16/04 01:57 cdaq Run 49660: daq test
87358 07/16/04 01:56 cdaq Run 49659: daq test
87357 07/16/04 01:54 cdaq Run 49626: daq test after cdaql3 reboot
87356 07/16/04 00:59 R.Asaturyan Target
87355 07/16/04 00:44 cdaq Run 49658: 6% Cu - HMS P=3.857 theta =10.545
87354 07/16/04 00:36 clasie Negative sigma on the thresholds for run 49657
87353 07/16/04 00:18 cdaq Run 49657: 3% Carbon - HMS P=3.857 theta =10.545
87352 07/16/04 00:08 cseely third time's a charm: 49652 is the run with the problem during replay...
Thursday
87351 07/15/04 23:56 Huber Swing shift summary
87350 07/15/04 23:29 cdaq Run 49656: 3% Carbon - HMS P=3.857 theta =10.545
87349 07/15/04 22:55 Huber HMS drift chambers tripped off at end of run 49655
87348 07/15/04 22:52 cseely third time's a charm: 49652 is the run with the problem during replay...
87347 07/15/04 22:51 cdaq Run 49655: 3% Carbon - HMS P=3.857 theta =10.545
87346 07/15/04 22:36 cdaq Run 49654: 3% Carbon - HMS P=3.857 theta =10.545
87345 07/15/04 22:36 cseely run 49653 is run with the problem during replay, not 49602...
87344 07/15/04 22:36 cseely run 49653 is run with the problem during replay, not 49602...
87343 07/15/04 22:16 cseely run 49602 replay stopped after 1/3 of the run???
87342 07/15/04 22:02 cdaq Run 49653: 3% Carbon - HMS P=3.857 theta =10.545
87341 07/15/04 21:27 cdaq Run 49652: 3% Carbon - HMS P=3.857 theta =10.545
87340 07/15/04 20:53 cdaq Run 49651: 3% Carbon - HMS P=3.857 theta =10.545
87339 07/15/04 20:18 cdaq Run 49650: 3% Carbon - HMS P=3.857 theta =10.545
87338 07/15/04 20:15 cdaq Run 49649: 3% Carbon - HMS P=3.857 theta =10.545
87337 07/15/04 19:39 cdaq Run 49648: 3% Carbon - HMS P=3.857 theta =10.545
87336 07/15/04 19:06 cseely Loop 1 temperature droped by 1 degree. recovered now
87335 07/15/04 19:06 cdaq Run 49647: 3% Carbon - HMS P=3.857 theta =10.545
87334 07/15/04 18:35 cdaq Run 49646: 3% Carbon - HMS P=3.857 theta =10.545
87333 07/15/04 18:35 hcf about warm alcohol
87332 07/15/04 18:07 cdaq Run 49645: 3% Carbon - HMS P=3.857 theta =10.545
87331 07/15/04 17:28 cdaq Run 49644: cosmics run to check SOS DC
87330 07/15/04 17:27 cseely updated SOS thresholds with cosmics run thresholds: 49643
87329 07/15/04 17:26 cseely
87328 07/15/04 16:49 cdaq Run 49643: cosmics run to check SOS DC
87327 07/15/04 16:32 cseely target checklist.
87326 07/15/04 16:26 cdaq Run 49642: cosmics run to check SOS DC
87325 07/15/04 16:24 cseely SOS Hodoscope pedestals
87324 07/15/04 16:16 cdaq Beam Time Accounting
87323 07/15/04 16:15 Bosted Day shift summary
87322 07/15/04 16:09 Bosted HMS DC trip
87321 07/15/04 16:08 Bosted Fridge door found open in gas shed
87320 07/15/04 16:06 bosted HMS magnets restore
87319 07/15/04 15:46 cdaq Run 49641: SOS pedestal test - New ADC in slot 9
87318 07/15/04 15:41 Vipuli target check list
87317 07/15/04 15:33 hcf SOS DC1X49 fixed
87316 07/15/04 15:28 saw ADC Swap
87315 07/15/04 14:53 cdaq Run 49638: SOS pedestal test
87314 07/15/04 14:29 Bosted plan for next shift
87313 07/15/04 14:26 Bosted HMS quadrupoles
87312 07/15/04 14:08 hcf drift chamber hot/dead wire fixes
87311 07/15/04 13:34 cdaq Run 49637: COSMIC run to test HMS DC
87310 07/15/04 13:15 mack ADC problem apparently not due to dropping a single bit
87309 07/15/04 13:03 cdaq Run 49636: 3COSMIC run for PEDS
87308 07/15/04 12:52 cdaq Run 49635: 3COSMIC run for PEDS
87307 07/15/04 12:31 cdaq Run 49634: 3COSMIC run for PEDS
87306 07/15/04 11:20 johna SOS pedestal problems
87305 07/15/04 10:54 cdaq Run 49633: 3COSMIC run for PEDS
87303 07/15/04 10:32 cdaq Run 49632: 3COSMIC run for PEDS
87302 07/15/04 10:15 cdaq Run 49631: Cosmic test with nob beam
87301 07/15/04 09:17 cdaq Run 49630: 3% Carbon - HMS P=3.857 theta =10.545
87300 07/15/04 08:28 cdaq Run 49629: 3% Carbon - HMS P=3.857 theta =10.545
87299 07/15/04 08:16 cdaq Beam Time Accounting
87298 07/15/04 08:12 clasie owl shift summary
87296 07/15/04 07:33 cdaq Run 49628: 3% Carbon - HMS P=3.857 theta =10.545
87295 07/15/04 07:01 cdaq Run 49627: 3% Carbon - HMS P=3.857 theta =10.545
87294 07/15/04 06:54 clasie HMS pc
87293 07/15/04 06:29 cdaq Run 49626: 3% Carbon - HMS P=3.857 theta =10.545
87292 07/15/04 05:55 cdaq Run 49625: 3% Carbon - HMS P=3.857 theta =10.545
87291 07/15/04 05:01 cdaq Run 49624: 3% Carbon - HMS P=3.857 theta =10.545
87290 07/15/04 05:01 R.Asaturyan target
87289 07/15/04 05:00 R.Asaturyan target
87288 07/15/04 04:29 cdaq Run 49623: Al dummy - HMS P=3.857 theta =10.545
87287 07/15/04 04:16 cdaq Run 49622: Al dummy - HMS P=3.857 theta =10.545
87286 07/15/04 03:51 R.Asaturyan target
87285 07/15/04 03:30 cdaq Beam Time Accounting
87284 07/15/04 03:26 clasie Beam is back
87283 07/15/04 03:25 cdaq Run 49621: LH2 - HMS P=3.857 theta =10.545
Wednesday
87282 07/14/04 21:16 Huber Down until storm passes
87281 07/14/04 20:11 cdaq Run 49620: LH2 - HMS P=3.857 theta =10.545
87280 07/14/04 19:38 cdaq Run 49619: LH2 - HMS P=3.857 theta =10.545
87279 07/14/04 18:48 cdaq Run 49618: LH2 - HMS P=3.857 theta =10.545
87278 07/14/04 18:07 cdaq Run 49617: LH2 - HMS P=3.857 theta =10.545
87277 07/14/04 17:37 cdaq Run 49616: LH2 - HMS P=3.857 theta =10.545
87276 07/14/04 17:07 cdaq Run 49615: LH2 - HMS P=3.857 theta =10.545
87275 07/14/04 16:20 akopper elog test
87274 07/14/04 16:17 cdaq Beam Time Accounting
87273 07/14/04 16:09 akopper target checklist
87272 07/14/04 16:09 akopper target checklist
87271 07/14/04 15:56 vulcan day shift summary
87270 07/14/04 15:55 vulcan day shift summary
87269 07/14/04 15:25 cdaq Run 49614: LH2 - HMS P=3.857 theta =10.545
87268 07/14/04 15:19 vulcan HWP
87267 07/14/04 14:48 okayasu Target change
87266 07/14/04 14:47 okayasu Target change
87265 07/14/04 14:44 cdaq Run 49613: LH2 - HMS P=3.857 theta =10.545
87264 07/14/04 14:12 cdaq Run 49612: LD2 - HMS P=3.857 theta =10.545
87263 07/14/04 14:07 cseely BCM calibration run: 49592
87262 07/14/04 13:39 cdaq Run 49611: LD2 - HMS P=3.857 theta =10.545
87261 07/14/04 13:37 tigran Hot wire.
87260 07/14/04 13:06 cdaq Run 49610: LD2 - HMS P=3.857 theta =10.545
87259 07/14/04 12:35 cdaq Run 49609: LD2 - HMS P=3.857 theta =10.545
87258 07/14/04 11:57 vulcan Entry to hall
87256 07/14/04 11:33 cseely ramping down HMS dipole
87251 07/14/04 08:24 cdaq Run 49608: LD2 - HMS P=3.857 theta =10.545
87250 07/14/04 08:06 cseely target checklist
87249 07/14/04 08:01 cdaq Beam Time Accounting
87248 07/14/04 07:50 R.Asaturyan owl shift summary
87247 07/14/04 07:49 cdaq Run 49607: LD2 - HMS P=3.857 theta =10.545
87246 07/14/04 07:19 cdaq Run 49606: LD2 - HMS P=3.857 theta =10.545
87245 07/14/04 07:07 clasie changes to missing mass in the analyzer
87243 07/14/04 06:32 cdaq Run 49605: LD2 - HMS P=3.857 theta =10.545
87242 07/14/04 06:00 cdaq Run 49604: LD2 - HMS P=3.857 theta =10.545
87241 07/14/04 05:13 cdaq Run 49603: LD2 - HMS P=3.857 theta =10.545
87240 07/14/04 04:40 cdaq Run 49602: LD2 - HMS P=3.857 theta =10.545
87239 07/14/04 04:37 clasie Target: change to deuterium
87238 07/14/04 04:37 clasie Target: HPH loop2 alarm
87237 07/14/04 03:52 cdaq Run 49601: H2 - HMS P=3.857 theta =10.545
87236 07/14/04 03:11 cdaq Run 49600: H2 - HMS P=3.857 theta =10.545
87235 07/14/04 03:03 clasie `MCC: half wave plate will be removed for hall A
87234 07/14/04 02:32 clasie MCC: Box supply went down
87233 07/14/04 02:17 cdaq Run 49599: H2 - HMS P=3.857 theta =10.545
87232 07/14/04 02:10 donal BCM screens
87231 07/14/04 01:39 cdaq Run 49598: H2 - HMS P=3.857 theta =10.545
87230 07/14/04 01:18 clasie MCC: lost two rf zones
87229 07/14/04 01:06 cdaq Run 49597: H2 - HMS P=3.857 theta =10.545
87228 07/14/04 01:04 cdaq Run 49596: H2 - HMS P=3.857 theta =10.545
87227 07/14/04 01:03 cdaq Run 49595: H2 - HMS P=3.857 theta =10.545
87226 07/14/04 00:55 cdaq Run 49594: H2 - HMS P=3.857 theta =10.545
87225 07/14/04 00:53 cdaq Run 49593: H2 - HMS P=3.857 theta =10.545
87224 07/14/04 00:10 cdaq Beam Time Accounting
87223 07/14/04 00:10 clasie Target: checklist
87221 07/14/04 00:04 cseely swing shift summary
Tuesday
87220 07/13/04 23:32 cdaq Run 49592:
87219 07/13/04 23:24 cseely target checklist
87218 07/13/04 23:11 cseely AND WE'RE BACK!
87217 07/13/04 22:56 cseely putting in LH2 target - beam is coming!
87216 07/13/04 21:38 cseely "good news and bad news" - from MCC
87214 07/13/04 19:04 cseely HMS magnets back up. ready for beam if we can get it...
87211 07/13/04 18:52 cseely gasmaster alarm
87201 07/13/04 16:42 cseely HMS Quads ramped down, now in standby. dipole still ramping down
87198 07/13/04 16:28 cseely ramping down all HMS magnets for work in hall
87197 07/13/04 16:22 cdaq Beam Time Accounting
87195 07/13/04 16:08 cseely target checklist
87194 07/13/04 15:15 vulcan Beam,Where art thou!
87193 07/13/04 14:33 fomin target moved to empty
87192 07/13/04 13:50 fomin Drift Chamber High Voltage trip
87182 07/13/04 10:16 fomin target checlist
87181 07/13/04 08:18 cdaq Beam Time Accounting
87180 07/13/04 01:36 villaa BEAM DOWN for the night (at least)
87179 07/13/04 01:21 villaa Power Surge/ HPH power spike
Monday
87178 07/12/04 23:58 cdaq Beam Time Accounting
87173 07/12/04 22:18 Huber Down for Hall C laser work
87171 07/12/04 19:22 M Jones Change to Analyzer engine
87170 07/12/04 18:22 cseely one more set of luminosity scan plots
87169 07/12/04 17:31 Huber Run 49591 is first BCM calibration run
87168 07/12/04 17:19 cdaq Beam Time Accounting
87167 07/12/04 16:50 cseely shift summary, day
87166 07/12/04 16:23 cdaq Run 49591:
87165 07/12/04 16:09 lassiter Rotation of HMSs
87164 07/12/04 16:05 cdaq Run 49590:
87163 07/12/04 16:04 akopper target checklist
87162 07/12/04 16:03 akopper target checklist
87161 07/12/04 16:02 akopper target checklist
87160 07/12/04 15:38 cdaq Run 49589:
87159 07/12/04 15:00 saw Reasons for running unbuffered mode
87157 07/12/04 14:48 cseely DAQ running in unbuffered mode
87156 07/12/04 14:05 cdaq Run 49588: H2 - HMS P=3.187 theta =13.44
87155 07/12/04 13:56 cdaq Run 49587: H2 - HMS P=3.187 theta =13.44
87154 07/12/04 12:59 clasie pion plots
87153 07/12/04 12:25 cdaq Run 49586: H2 - HMS P=3.187 theta =13.44
87152 07/12/04 12:05 cdaq Run 49585: H2 - HMS P=3.187 theta =13.44
87151 07/12/04 11:54 fomin target moved to LH2
87150 07/12/04 11:32 cseely HMS Q1 and Q2 ready
87149 07/12/04 11:24 fomin target moved to EMPTY for beam studies
87148 07/12/04 11:11 cseely checked radcon area markers - all clear
87144 07/12/04 08:26 fomin LD2 target parked
87143 07/12/04 08:16 fomin target checklist
87142 07/12/04 08:06 aamer checklist scan
87141 07/12/04 08:03 cdaq Beam Time Accounting
87140 07/12/04 07:39 R.Asaturyan Owl shift summary
87139 07/12/04 06:17 cdaq Run 49583: Au - HMS P=3.187 theta =13.44
87138 07/12/04 05:43 cdaq Run 49582: Au - HMS P=3.187 theta =13.44
87137 07/12/04 05:31 cdaq Run 49581: Au - HMS P=3.187 theta =13.44
87136 07/12/04 04:56 cdaq Run 49580: Au - HMS P=3.187 theta =13.44
87135 07/12/04 04:20 cdaq Run 49579: Au - HMS P=3.187 theta =13.44
87134 07/12/04 03:43 cdaq Run 49578: Cu - HMS P=3.187 theta =13.44
87133 07/12/04 03:17 cdaq Run 49577: Cu - HMS P=3.187 theta =13.44
87132 07/12/04 02:43 cdaq Run 49576: Cu - HMS P=3.187 theta =13.44
87131 07/12/04 02:11 cdaq Run 49575: Cu - HMS P=3.187 theta =13.44
87130 07/12/04 01:42 cdaq Run 49574: Cu - HMS P=3.187 theta =13.44
87129 07/12/04 01:11 cdaq Run 49573: Cu - HMS P=3.187 theta =13.44
87128 07/12/04 00:34 cdaq Run 49572: Cu - HMS P=3.187 theta =13.44
87127 07/12/04 00:01 cdaq Beam Time Accounting
Sunday
87126 07/11/04 23:59 cdaq Run 49571: Cu - HMS P=3.187 theta =13.44
87125 07/11/04 23:54 Huber Swing shift summary
87124 07/11/04 23:25 cdaq Run 49570: Au - HMS P=3.187 theta =13.44
87123 07/11/04 22:55 cdaq Run 49569: Au - HMS P=3.187 theta =13.44
87122 07/11/04 22:24 cseely target IOC reboot.
87121 07/11/04 22:22 cdaq Run 49567: Au - HMS P=3.187 theta =13.44
87120 07/11/04 21:52 cdaq Run 49566: Au - HMS P=3.187 theta =13.44
87119 07/11/04 21:37 cdaq Run 49565: Au - HMS P=3.187 theta =13.44
87118 07/11/04 21:36 cseely corrected luminosity scan plots - thes include delta cuts
87117 07/11/04 21:12 Huber Will Robinson
87116 07/11/04 21:08 cdaq Run 49564: Au - HMS P=3.187 theta =13.44
87115 07/11/04 21:00 Huber More HMS Q2 trips
87114 07/11/04 21:00 cdaq Run 49563: Au - HMS P=3.187 theta =13.44
87113 07/11/04 20:57 cseely corrected luminosity scan plots - thes include delta cuts
87112 07/11/04 19:27 mack Dave requests a BCM calibration
87111 07/11/04 19:19 cseely Q2 tripped again...called MCC to ask for lower current: 30uA
87110 07/11/04 19:09 Huber HMS Q2 trip
87109 07/11/04 19:08 cdaq Run 49562: Au - HMS P=3.187 theta =13.44
87108 07/11/04 18:53 cseely target change: from LH2 to Au
87107 07/11/04 18:42 cseely yields per mC for luminosity scan
87106 07/11/04 18:39 cdaq Run 49561: Au - HMS P=3.187 theta =13.44
87105 07/11/04 18:08 cdaq Run 49560: Au - HMS P=3.187 theta =13.44
87104 07/11/04 18:07 mack raising ion chamber thresholds
87103 07/11/04 18:06 Huber HMS moved to 13.44deg
87102 07/11/04 17:31 Garrow New SOS pedestal thresholds
87101 07/11/04 17:28 cdaq Run 49559: LH2 - HMS P=3.187 theta =10.54
87100 07/11/04 17:19 cseely changed to LH2 target from Au
87099 07/11/04 17:19 cdaq Run 49558: LH2 - HMS P=3.187 theta =10.54
87098 07/11/04 17:00 bosted Day shift summary
87097 07/11/04 16:40 clasie gas yard checks
87096 07/11/04 16:37 Huber HMS moved to 10.54deg
87095 07/11/04 16:37 cdaq Beam Time Accounting
87094 07/11/04 16:10 cseely target checklist
87093 07/11/04 12:39 cdaq Run 49557: HMS P=3.187 theta =10.53
87092 07/11/04 12:37 clasie Target: target changed to 6%Au
87091 07/11/04 12:26 cdaq Run 49556: HMS P=3.187 theta =10.53
87090 07/11/04 12:17 clasie Target: change to 6%Cu
87089 07/11/04 12:01 bosted WC HV trip
87088 07/11/04 11:37 clasie Target: Change to empty
87087 07/11/04 11:32 bosted beam current limited to 40 muA
87086 07/11/04 11:07 cdaq Run 49555: HMS P=3.187 theta =10.53
87085 07/11/04 10:28 garrow Increase in beam dump and pivot ion chanber thresholds
87084 07/11/04 10:20 cdaq Run 49554: HMS P=3.187 theta =10.53
87083 07/11/04 10:16 clasie Target: change to LH2
87082 07/11/04 10:03 clasie Target: target changed to empty
87081 07/11/04 09:33 cdaq Run 49553: HMS P=3.187 theta =10.53
87080 07/11/04 09:28 cdaq Run 49552: HMS P=3.187 theta =16.45
87079 07/11/04 08:53 cdaq Run 49552: HMS P=3.187 theta =16.45
87078 07/11/04 08:49 clasie Target: change to Al Dummy
87077 07/11/04 08:15 clasie Target: target checklist
87076 07/11/04 08:09 cdaq Beam Time Accounting
87075 07/11/04 07:59 aamer owl shift summary
87074 07/11/04 07:45 cdaq Run 49551: HMS P=3.187 theta =16.45
87073 07/11/04 07:12 cdaq Run 49550: HMS P=3.187 theta =16.45
87072 07/11/04 06:38 cdaq Run 49549: HMS P=3.187 theta =16.45
87071 07/11/04 06:37 cdaq Run 49548: HMS P=3.187 theta =16.45
87070 07/11/04 06:34 bruell target moved to LH2, 6% copper target impossible to run!
87069 07/11/04 06:31 aamer HMS angle is 16.45 degrees
87068 07/11/04 06:31 aamer Trip with Cu target too
87067 07/11/04 05:02 bruell target changed to Al (dummy)
87066 07/11/04 05:02 cdaq Run 49547: HMS P=3.187 theta =13.44
87065 07/11/04 04:55 bruell target changed to LD2
87064 07/11/04 04:16 cdaq Run 49546: HMS P=3.187 theta =13.44
87063 07/11/04 04:10 cseely corrected luminoisity scans for HMS and SOS
87062 07/11/04 03:47 cdaq Run 49545: HMS P=3.187 theta =13.44
87061 07/11/04 03:07 cdaq Run 49544: HMS P=3.187 theta =13.44
87060 07/11/04 03:05 aamer hall A
87059 07/11/04 02:31 bruell target changed to LH2
87058 07/11/04 02:28 cdaq Run 49543: HMS P=3.187 theta =13.44
87057 07/11/04 01:47 ddutta SOS beam steering test
87056 07/11/04 01:44 ddutta SOS beam steering test
87055 07/11/04 01:35 cdaq Run 49542: HMS P=3.187 theta =13.44
87054 07/11/04 00:47 cdaq Run 49541: HMS P=3.187 theta =13.44
87053 07/11/04 00:17 cdaq Run 49540: HMS P=3.187 theta =13.44
87052 07/11/04 00:07 Huber Swing shift summary
87051 07/11/04 00:04 cdaq Beam Time Accounting
Saturday
87050 07/10/04 23:04 cdaq Run 49539: Heep run - Dummy - HMS P=+4.116 angle 18
87049 07/10/04 21:44 Huber Down again for another injector access
87048 07/10/04 21:36 cseely luminosity scan on C(3%), LH2, LD2 - HMS results
87047 07/10/04 21:24 cseely minor hi alarm from target_vacuum
87046 07/10/04 21:19 cdaq Run 49538: Heep run - Dummy - HMS P=+4.116 angle 18
87045 07/10/04 20:16 Huber Runs 49528-49537 are not sieve slit. Run header is in error.
87044 07/10/04 20:15 cseely moved to Al dummy target from LH2 target
87043 07/10/04 18:47 Huber Beam off for next 2 hours for injector access
87042 07/10/04 18:16 cdaq Run 49537: Heep run - HMS P=+4.116 angle 18 sieve slit
87041 07/10/04 17:40 cseely target checklist
87040 07/10/04 17:35 cdaq Run 49536: Heep run - HMS P=+4.116 angle 18 sieve slit
87039 07/10/04 17:08 cdaq Run 49535: Heep run
87038 07/10/04 16:49 clasie Shift summary
87037 07/10/04 16:47 cseely stepped Loop 2 JT closed a bit
87036 07/10/04 16:38 cdaq Run 49534: Heep run
87035 07/10/04 16:08 cdaq Beam Time Accounting
87034 07/10/04 16:08 cdaq Run 49533: Heep run
87033 07/10/04 16:03 cdaq Run 49532: HMS angle 18 sieve slit
87032 07/10/04 16:03 cdaq Run 49532: HMS angle 18 sieve slit
87031 07/10/04 15:58 cdaq Run 49530: HMS angle 18 sieve slit
87030 07/10/04 15:27 cdaq Run 49528: HMS angle 18 sieve slit
87029 07/10/04 15:26 Xin Target was changed back to H2 at 15:30.
87028 07/10/04 15:26 Xin Change target to 3% carbon at 13:00
87027 07/10/04 14:51 cdaq Run 49527: HMS angle 18 sieve slit
87026 07/10/04 14:49 cdaq Run 49526: HMS angle 18 sieve slit
87025 07/10/04 14:34 cdaq Run 49525: BPM check with 3%C and sieve slit in HMS
87024 07/10/04 13:46 cdaq Run 49524: Heep run
87023 07/10/04 13:40 cdaq Run 49523: HMS angle 25 pion collimator
87022 07/10/04 13:24 cdaq Run 49522: HMS angle 25 pion collimator
87021 07/10/04 13:23 cdaq Run 49522: HMS angle 25 pion collimator
87020 07/10/04 11:36 cdaq Run 49520: HMS angle 25 pion collimator
87019 07/10/04 11:09 cdaq Run 49519: Heep run
87018 07/10/04 10:59 Xin Change target to H2
87017 07/10/04 09:19 cdaq Beam Time Accounting
87016 07/10/04 09:05 clasie HMS Q2 can be controlled from the CH
87015 07/10/04 08:59 Xin Target checklist
87014 07/10/04 06:34 aamer owl shift summary
87013 07/10/04 06:22 bruell target moved to LD2
87012 07/10/04 06:22 bruell target moved to LH2
87011 07/10/04 06:21 bruell target moved to Al (dummy)
87010 07/10/04 06:21 cdaq Run 49518: HMS angle 25 pion collimator
87009 07/10/04 06:14 cdaq Run 49517: HMS angle 25 pion collimator
87008 07/10/04 06:07 cdaq Run 49516: HMS angle 25 pion collimator
87007 07/10/04 06:01 cdaq Run 49515: HMS angle 25 pion collimator
87006 07/10/04 05:56 cdaq Run 49514: HMS angle 25 pion collimator
87005 07/10/04 05:51 bruell target moved to 3% Carbon
87004 07/10/04 05:48 cdaq Run 49513: HMS angle 25 pion collimator
87003 07/10/04 05:47 bruell target moved to LD2
87002 07/10/04 05:41 cdaq Run 49512: HMS angle 25 pion collimator
87001 07/10/04 05:35 cdaq Run 49511: HMS angle 25 pion collimator
87000 07/10/04 05:32 cdaq Run 49510: HMS angle 25 pion collimator
86999 07/10/04 05:32 bruell target moved to LH2
86998 07/10/04 05:26 bruell target moved to LD2
86997 07/10/04 05:25 cdaq Run 49509: HMS angle 25 pion collimator
86996 07/10/04 05:16 cdaq Run 49508: HMS angle 25 pion collimator
86995 07/10/04 05:10 bruell target moved to 3% Carbon
86994 07/10/04 05:04 bruell target moved to LD2
86993 07/10/04 05:01 bruell
86992 07/10/04 05:00 cdaq Run 49507: HMS angle 25 pion collimator
86991 07/10/04 05:00 bruell target moved to LH2
86990 07/10/04 04:48 cdaq Run 49506: HMS angle 25 pion collimator
86989 07/10/04 04:33 cdaq Run 49505: HMS angle 25 pion collimator
86988 07/10/04 04:21 ddutta beam position with sieve slits
86987 07/10/04 04:19 bruell
86986 07/10/04 03:26 cdaq Run 49504: HMS angle 25
86985 07/10/04 02:54 cdaq Run 49503: HMS angle 25
86984 07/10/04 02:49 cseely same harp scan...
86983 07/10/04 02:45 cseely harp scan
86982 07/10/04 02:43 Bruell target moved to 10% Carbon
86981 07/10/04 02:38 cdaq Run 49502: HMS angle 25
86980 07/10/04 02:14 Bruell fan speed of deuterium target
86979 07/10/04 02:07 cdaq Run 49501: HMS angle 24.9
86978 07/10/04 02:00 Bruell target movement
Friday
86977 07/09/04 23:41 cdaq Run 49500: dummy run
86976 07/09/04 21:03 cseely SOS new angle vernier and camera moved back to original position
86975 07/09/04 20:00 cseely moving from 6% Cu back to 'empty'
86974 07/09/04 20:00 cseely moving from LH2 target to 6% Cu target
86973 07/09/04 19:53 cseely moving target from empty to LH2
86972 07/09/04 18:42 cseely target operators: check loop 1, sensor 2 for alarm settings
86971 07/09/04 18:20 smithg Target cooldown completed
86970 07/09/04 18:18 Fowler Spectrometer Rotation
86956 07/09/04 15:51 cdaq Run 49499: short run to check SOS TOF 2x16+
86955 07/09/04 14:55 cdaq Run 49498: short run to check SOS TOF 2x16+
86954 07/09/04 14:28 saw Divided RF to TDC
86953 07/09/04 14:17 cdaq Run 49497: Test RF into TDC
86952 07/09/04 14:15 smithg Target status
86951 07/09/04 12:56 cseely reformatted: scer, hcer, haero calibrations using comsics
86950 07/09/04 12:56 cseely scer, hcer, haero calibrations using comsics
86949 07/09/04 11:48 hcf HMS DC1-X113 card swapped AND -5V PS fuse replaced
86948 07/09/04 11:36 gaskell sos 2x16+ signal found
86947 07/09/04 11:35 cdaq Run 49496: cosmic check of sos h2x plane
86946 07/09/04 10:33 cseely HMS calorimeter trip - bad tube?
86945 07/09/04 10:25 cdaq Run 49495: quick cosmic run to check sos h2x signals
86944 07/09/04 08:12 gaskell SOS magnets turned off
Thursday
86943 07/08/04 20:37 cdaq Run 49494: long cosmics run overnight...
86942 07/08/04 20:28 cseely adjustment to new SOS angle vernier scale and camera
86941 07/08/04 19:19 cseely moved hpre200 signal to new level translator
86940 07/08/04 18:33 cdaq Run 49493: cosmics run - HMS trigger test, 1/4 trigger, put pre200 signal into where hCERHI was, electronics map updated
86939 07/08/04 18:15 cdaq Run 49492: cosmics run - HMS trigger test, 1/4 trigger, put pre200 signal into where hCERHI was, electronics map updated
86938 07/08/04 18:09 cdaq Run 49491: cosmics run - HMS trigger test, 1/4 trigger, put pre200 signal into where hCERHI was, electronics map updated
86937 07/08/04 17:56 cdaq Run 49490: cosmics run - HMS trigger test, 1/4 trigger, put pre200 signal into where hCERHI was
86936 07/08/04 17:48 cdaq Run 49489: cosmics run - test. removed hCERHI
86935 07/08/04 17:21 cseely SOS cerenkov pedestals and thresholds in Analyzer
86934 07/08/04 17:21 cseely SOS cerenkov pedestals and thresholds in Analyzer
86933 07/08/04 17:13 cdaq Run 49488: cosmics run - testing SOS cer threshold outputs
86932 07/08/04 17:08 nakahara Additional TLDs placed in Hall
86930 07/08/04 17:08 cseely replaced 3 bases on SOS hodoscopes
86929 07/08/04 16:35 cseely replaced 3 bases on SOS hodoscopes
86928 07/08/04 16:16 cdaq Run 49487: cosmics run - new SOS hodo bases
86927 07/08/04 15:07 cdaq Run 49486: cosmics run - new SOS hodo bases
86926 07/08/04 14:52 saw HV guil updated for SOS S2x7-
86925 07/08/04 14:22 cdaq Run 49485: HMS pre50 study...1/4 trigger.
86924 07/08/04 13:33 cdaq Run 49484: HMS pre50 study...1/4 trigger. pre100=pre150 and PION=pre150
86923 07/08/04 13:24 cdaq Run 49483: HMS pre50 study...1/4 trigger. pre100=pre200 and PION=pre200
86922 07/08/04 13:08 cdaq Run 49482: HMS pre50 study...1/4 trigger. pre100=pre100 and PION=pre100
86921 07/08/04 12:59 cdaq Run 49481: HMS pre50 study...1/4 trigger. pre100=pre50 and PION=pre50
86920 07/08/04 12:25 cdaq Run 49480: HMS pre50 study...1/4 trigger. pre100=pre150 and PION=pre150
86919 07/08/04 12:19 cdaq Run 49479: HMS pre50 study...1/4 trigger. pre100=pre200 and PION=pre200
86918 07/08/04 12:10 cdaq Run 49478: HMS pre50 study...1/4 trigger. pre100=pre150 and PION=pre150
86917 07/08/04 11:59 Lassiter HMS Magnets
86916 07/08/04 11:38 cdaq Run 49477: HMS pre50 study...1/4 trigger. pre100=pre100 and PION=pre100
86915 07/08/04 11:23 cdaq Run 49476: HMS pre50 study...1/4 trigger. pre50=pre50 and PION=pre50
86914 07/08/04 11:14 cdaq Run 49475: HMS pre50 study...1/4 trigger. removed PION signal from its level translator
86913 07/08/04 11:03 cdaq Run 49474: HMS pre50 study...1/4 trigger. normal setup
86912 07/08/04 10:37 cseely moved S2x7- to a new HV channel
86911 07/08/04 10:22 cdaq Run 49473: cosmics to check new HV channel for S2x7-
Wednesday
86910 07/07/04 18:51 cseely SOS Cerenkov pedestals
86909 07/07/04 18:27 cseely no resolution of HMS pre50 problem
86908 07/07/04 18:06 cdaq Run 49472: long cosmics run, 3/4 trigger
86907 07/07/04 18:04 cseely HV on for cosmics run overnight: SOS 2x7- hodoscope undervoltage so turned off...
86906 07/07/04 17:37 cdaq Run 49471: HMS and SOS trigger test
86905 07/07/04 17:30 cdaq Run 49470: HMS and SOS trigger test
86904 07/07/04 17:23 cdaq Run 49469: HMS and SOS trigger test
86903 07/07/04 17:00 cdaq Run 49468: HMS and SOS trigger test
86902 07/07/04 16:55 cdaq Run 49467: HMS and SOS trigger test
86901 07/07/04 16:46 cdaq Run 49466: HMS and SOS trigger test
86900 07/07/04 16:36 cdaq Run 49465: HMS and SOS trigger test
86899 07/07/04 16:30 cdaq Run 49464: HMS and SOS trigger test
86898 07/07/04 16:24 cseely quick note about HMS pre50 and pre200 weirdness
86897 07/07/04 15:44 Lassiter HMS Dipole
86896 07/07/04 15:38 cdaq Run 49463: HMS and SOS trigger test
86895 07/07/04 15:30 cdaq Run 49462: HMS and SOS trigger test
86894 07/07/04 15:18 cdaq Run 49461: HMS and SOS trigger test
86893 07/07/04 15:04 cdaq Run 49460: HMS and SOS trigger test
86892 07/07/04 14:54 cdaq Run 49459: HMS and SOS trigger test
86891 07/07/04 14:37 cdaq Run 49458: HMS and SOS trigger test
86890 07/07/04 14:23 cdaq Run 49457: HMS and SOS trigger test
86889 07/07/04 14:17 cseely SOS Hodoscope HV on for trigger tests...
86888 07/07/04 13:21 cdaq Run 49456: HMS trigger test
86887 07/07/04 12:58 cdaq Run 49455: HMS trigger test
86886 07/07/04 12:52 cdaq Run 49454: HMS trigger test
86885 07/07/04 12:35 cdaq Run 49453: HMS trigger test
86884 07/07/04 12:14 cdaq Run 49452: HMS trigger test
86883 07/07/04 11:26 cdaq Run 49451: HMS trigger test
86882 07/07/04 11:16 cdaq Run 49450: HMS trigger test
86881 07/07/04 11:12 cseely HMS Hodoscops and Cer HV are on for some trigger tests
86880 07/07/04 10:37 cdaq Run 49448: DAQ Test
86879 07/07/04 10:20 clasie HMS gas Cerenkov pressure was increased yesturday
Tuesday
86878 07/06/04 17:13 cseely followup to SOS Cerenkov threshold message
86876 07/06/04 16:38 cdaq Run 49447: DAQ Test
86875 07/06/04 16:38 smithg target & pivot girder alignment survey results
86874 07/06/04 15:13 cseely SOS Cerenkov thresholds set to 0
86872 07/06/04 13:22 cdaq Run 49446: dummy
86871 07/06/04 12:11 cseely termination in trigger logic
86870 07/06/04 11:57 nakahara More TLDs in Hall
86868 07/06/04 11:16 nakahara TLD readings in HallC
Saturday
86866 07/03/04 20:31 cdaq Run 49444: HMS trigger test
86865 07/03/04 20:27 cdaq Run 49443: HMS trigger test
86864 07/03/04 20:23 cdaq Run 49442: HMS trigger test
86863 07/03/04 19:31 cdaq Run 49441: HMS trigger test
86862 07/03/04 19:23 cdaq Run 49440: HMS trigger test
86861 07/03/04 19:18 cdaq Run 49439: HMS trigger test
86860 07/03/04 19:11 cdaq Run 49438: HMS trigger test
86859 07/03/04 19:01 cdaq Run 49437: HMS trigger test
86858 07/03/04 18:55 cdaq Run 49436: HMS trigger test
Friday
86856 07/02/04 14:57 Lung Limited Weekend Access to Hall
86855 07/02/04 14:47 cdaq Beam Time Accounting
86854 07/02/04 14:18 hamlet HV on all HMS and SOS detectors are OFF
86853 07/02/04 14:02 hamlet HMS Aerogel detector back to normal operation
86852 07/02/04 11:22 Lung Radiation Survey
86851 07/02/04 10:45 hamlet,varda HMS Aerogel moved in
86850 07/02/04 10:39 cdaq Run 49435: HMS Aerogel cosmic test
86849 07/02/04 10:34 Lung Hall C Access
86848 07/02/04 08:45 hamlet SOS magnets off, HMS magnets set to 0 current
86847 07/02/04 08:30 Reimer Target: Moved to Empty
86846 07/02/04 08:20 clasie Target: changed to empty
86845 07/02/04 08:16 clasie Target: IOC reboot
86844 07/02/04 08:09 cdaq Beam Time Accounting
86843 07/02/04 08:06 M Jones Owl shift summary
86842 07/02/04 08:00 cdaq Run 49434: HMS: p=+1.32, th=46.00, SOS: p=+1.5, th=60.00
86841 07/02/04 07:57 clasie Target: change to 6%copper
86840 07/02/04 07:42 cdaq Run 49433: HMS: p=+1.32, th=46.00, SOS: p=+1.5, th=60.00
86839 07/02/04 07:20 cdaq Run 49432: HMS: p=+1.32, th=46.00, SOS: p=+1.5, th=60.00
86838 07/02/04 07:15 clasie Target: change to 3%carbon
86837 07/02/04 07:05 cdaq Run 49431: HMS: p=+1.32, th=46.00, SOS: p=+1.5, th=60.00
86836 07/02/04 06:58 clasie Target: change to dummy
86835 07/02/04 06:35 cdaq Run 49430: HMS: p=+1.32, th=46.00, SOS: p=+1.5, th=60.00
86834 07/02/04 06:26 clasie Target: change to LD2
86833 07/02/04 06:02 cdaq Run 49429: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86832 07/02/04 05:37 cdaq Run 49428: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86831 07/02/04 05:33 clasie Target: change to copper
86830 07/02/04 05:17 cdaq Run 49427: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86829 07/02/04 04:49 cdaq Run 49426: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86828 07/02/04 04:25 cdaq Run 49425: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86827 07/02/04 04:21 clasie Target: change to 3%Carbon
86826 07/02/04 04:02 cdaq Run 49424: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86825 07/02/04 03:34 cdaq Run 49423: HMS: p=+1.54, th=46.00, SOS: p=+1.5, th=60.00
86824 07/02/04 02:50 clasie Target: target changed to LD2
86823 07/02/04 02:27 cdaq Run 49422: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86822 07/02/04 02:17 clasie Target: change to dummy target
86821 07/02/04 01:48 clasie HMS dipole is back
86820 07/02/04 01:46 cdaq Run 49421: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86819 07/02/04 01:07 jwright HMS calorimeter: Channel misbehaving
86818 07/02/04 00:54 M Jones Beam energy modulation
86817 07/02/04 00:31 clasie HMS dipole trip
86816 07/02/04 00:25 cdaq Run 49420: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86815 07/02/04 00:08 clasie Target: target checklist
86814 07/02/04 00:03 cdaq Run 49419: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86813 07/02/04 00:02 cdaq Beam Time Accounting
Thursday
86812 07/01/04 23:51 ddutta swing shift summary
86811 07/01/04 23:32 cdaq Run 49418: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86810 07/01/04 23:04 Xin Target Checklist
86809 07/01/04 23:04 cdaq Run 49417: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86808 07/01/04 23:03 Xin Change target from carbon to copper
86807 07/01/04 22:29 cdaq Run 49416: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86806 07/01/04 21:47 cdaq Run 49415: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86805 07/01/04 21:31 Xin Changed target from LD2 to Carbon.
86804 07/01/04 21:31 cdaq Run 49414: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86803 07/01/04 21:20 cdaq Run 49413: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86802 07/01/04 19:52 gaskell Hall A energy modulation tests
86801 07/01/04 19:48 cdaq Run 49412: HMS: p=+1.8, th=46.00, SOS: p=-1.5, th=60.00
86800 07/01/04 19:46 Xin Change target from copper to LD2
86799 07/01/04 19:34 Donal Dipole problems
86798 07/01/04 18:33 cdaq Run 49410: HMS: p=not set, th=46.00, SOS: p=-1.7, th=60.00
86797 07/01/04 17:30 Xin Unpark the LD2 target
86796 07/01/04 17:30 Xin Unpark the LD2 target
86795 07/01/04 17:26 cdaq Run 49409: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86794 07/01/04 17:22 ddutta ens of run failed for 49407
86793 07/01/04 17:22 cdaq Run 49408: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86791 07/01/04 16:50 cdaq Run 49407: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86790 07/01/04 16:45 cdaq Run 49406: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86789 07/01/04 16:18 cdaq Run 49405: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86788 07/01/04 16:04 cdaq Beam Time Accounting
86787 07/01/04 16:03 Xin Target checklist
86786 07/01/04 16:00 Lung Day shift summary
86785 07/01/04 15:44 cdaq Run 49404: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86784 07/01/04 15:42 fomin Target moved to Copper
86783 07/01/04 15:24 fomin hms drift chamber (DC) high voltage trip
86782 07/01/04 15:19 cdaq Run 49403: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86781 07/01/04 14:58 cdaq Run 49402: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86780 07/01/04 14:38 cdaq Run 49401: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86779 07/01/04 14:23 fomin target moved from Carbon to Beryllium
86778 07/01/04 14:14 cdaq Run 49400: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86777 07/01/04 14:06 Lung HMS Q2 back on
86776 07/01/04 13:59 cdaq Run 49399: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86775 07/01/04 13:30 fomin HMS Q2 trip
86774 07/01/04 13:06 cdaq Run 49398: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86773 07/01/04 12:35 cdaq Run 49397: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86772 07/01/04 12:21 fomin LD2 target parked
86771 07/01/04 12:17 fomin target moved from LD2 to Carbon
86770 07/01/04 11:25 cdaq Run 49396: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86769 07/01/04 11:20 fomin target moved from Al Dummy to LD2
86768 07/01/04 11:07 Donal Ion chambers
86767 07/01/04 10:56 cdaq Run 49395: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=50.00
86766 07/01/04 10:49 fomin sos rotation
86765 07/01/04 10:49 fomin target moved from Cu to Al Dummy.
86764 07/01/04 10:34 cdaq Run 49394: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=40.00
86763 07/01/04 10:06 tigran Problem with run# 49392 .
86762 07/01/04 10:02 cdaq Beam Time Accounting
86761 07/01/04 09:57 cdaq Run 49393: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=40.00
86760 07/01/04 09:45 Donal Readings on the beamline
86759 07/01/04 09:45 cdaq Run 49392: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=40.00
86758 07/01/04 09:43 Fowler Rebooting HMS magnet computers
86757 07/01/04 09:41 cdaq Run 49391: HMS: p=-1.32, th=46.00, SOS: p=-1.7, th=40.00
86756 07/01/04 09:15 fomin target scattering chamber vacuum alarm
86755 07/01/04 08:46 fomin target chamber camera
86754 07/01/04 08:11 fomin target checklist
86753 07/01/04 07:51 rohe 7:30:vacuum experts went into hall
86752 07/01/04 07:49 vardan target vacuum
86751 07/01/04 06:40 rohe vacuum readings again
86750 07/01/04 04:37 rohe Vacuum readings
86749 07/01/04 00:44 vardan target checklist
86748 07/01/04 00:43 vardan
86747 07/01/04 00:04 cdaq Beam Time Accounting
This file generated by /group/hallc/www/hallcweb/apps/logbooks/hclog/src/hclogscript version HC2.04
If you have any comments or problems, please contact:
Stephen A. Wood
saw@jlab.org
(757) 269-7367