Main INDEX, Monthly INDEX, PREV, NEXT
Make New Entry, Make Followup Entry

User name puckett

Log entry time 16:32:19 on January 30, 2008

Entry number 150257

Followups:

keyword=Made separate map for runs with bad S0 cabling:

I made the map gep.map.bad_S0, which applies to the runs for which the S0 TDCs were improperly cabled. The only difference between this map and gep.map.63006 is that the + tubes for S0X1 and S0X2 are commented out, because they are not in the data. Their TDC channels were actually looking at copies of the neg. tube signals. I also updated MAIN.db so that the engine uses this map for runs 67657-68315 (beginning of kin. 7 to end of GEp-2g/beginning of WACS08). Since S0 is not used in the start time determination, this change shouldn't make much of a difference, but it is worth it to change the map to make sure these incorrectly labeled signals cannot have any unintended influence on the analysis.

A copy of this log entry has been emailed to: frw@jlab.org, jones@jlab.org