I have listed BPMs with their positions and RMS. The worst values are around 0l02 and then again at 0l10. Everything is good from li02 - li06, small and stable, and then at 0i02, things get bad and stay that way. This run was taken starting at 4am this morning.
(R is just sqrt(x^2+y^2))
1i02 R, mean: 0.1378 +-both 4.2830 um 1i04 R, mean: 0.0399 +-both 4.5272 um 1i06 R, mean: 0.1079 +-both 5.3573 um 0i02 R, mean: 0.0655 +-both 14.9942 um 0i02a R, mean: 0.1428 +-both 11.0452 um 0i05 R, mean: 0.1863 +-both 11.8756 um 0i07 R, mean: 0.1230 +-both 15.8662 um 0l02 R, mean: 0.2447 +-both 19.5329 um 0l03 R, mean: 0.1453 +-both 13.3928 um 0l04 R, mean: 0.1112 +-both 11.4993 um 0l05 R, mean: 0.0498 +-both 9.1592 um 0l06 R, mean: 0.1426 +-both 14.4887 um 0l07 R, mean: 0.1152 +-both 12.7743 um 0l08 R, mean: 0.0404 +-both 7.6446 um 0l09 R, mean: 0.0624 +-both 10.0053 um 0l10 R, mean: 0.1688 +-both 20.6556 um
1i02 X, mean: 0.1106 +- 1.3304 um 1i04 X, mean: -0.0394 +- 1.8721 um 1i06 X, mean: -0.1034 +- 1.2746 um 0i02 X, mean: 0.0426 +- 10.4935 um 0i02a X, mean: 0.0987 +- 6.3478 um 0i05 X, mean: -0.1862 +- 8.2094 um 0i07 X, mean: 0.0367 +- 8.6847 um 0l02 X, mean: -0.2381 +- 18.2704 um 0l03 X, mean: -0.0471 +- 5.8958 um 0l04 X, mean: 0.0030 +- 9.4644 um 0l05 X, mean: 0.0407 +- 3.9597 um 0l06 X, mean: 0.1425 +- 13.3605 um 0l07 X, mean: 0.0546 +- 5.9399 um 0l08 X, mean: 0.0044 +- 5.3296 um 0l09 X, mean: -0.0444 +- 5.0733 um 0l10 X, mean: -0.1657 +- 19.2703 um
1i02 Y, mean: 0.0823 +-both 4.0712 um 1i04 Y, mean: -0.0063 +-both 4.1219 um 1i06 Y, mean: 0.0311 +-both 5.2034 um 0i02 Y, mean: 0.0498 +-both 10.7104 um 0i02a Y, mean: 0.1031 +-both 9.0389 um 0i05 Y, mean: -0.0035 +-both 8.5811 um 0i07 Y, mean: 0.1174 +-both 13.2783 um 0l02 Y, mean: 0.0564 +-both 6.9086 um 0l03 Y, mean: -0.1374 +-both 12.0252 um 0l04 Y, mean: -0.1112 +-both 6.5313 um 0l05 Y, mean: 0.0288 +-both 8.2590 um 0l06 Y, mean: 0.0055 +-both 5.6054 um 0l07 Y, mean: 0.1014 +-both 11.3093 um 0l08 Y, mean: 0.0401 +-both 5.4804 um 0l09 Y, mean: 0.0438 +-both 8.6237 um 0l10 Y, mean: 0.0322 +-both 7.4371 um