Elong-13-04-24

From HallCWiki
Jump to: navigation, search

Rates Update

→ For the plot below, I assume the following:

Target Material ND3
Target Length 3 cm
fdil 6/20
pf 0.8
Pzz 20%
E0 11 GeV
xBjorken 0.1, 0.3, 0.5, 0.75, 1.0
Q2 Variable
θq Calculated
θe' Calculated
E' Calculated
W Calculated
→ Total rates have been included, and are shown plotted with the D2 rates
→ Error bars shown are statistical only
→ I found a slight bug from previous calculations: I was assuming the time output was in hours, but it was in fact in days
→ This has now been corrected, but all previous time calculations are under-estimated by a factor of 24
→ F1 and F2 are now calculated using the Bosted fits, which lets us extend into a higher x range
→ It is valid for 0<W<3.2 GeV and 0.2<Q2<5 GeV2
→ The rates note has been updated to fix the sign problems that Oscar and Dustin noted

2013-04-24-time.png

2013-04-24-db1d.png


No Prescales, Max rate = 1kHz

1kHz Max Rate
The max SHMS DAQ rate is 1kHz. The estimates above were done to show what we can do without prescales.
<x> dAzz with SHMS dAzz with HMS
0.1 0.0415 0.0448
0.3 0.0419 0.0415
0.5 0.0428 0.0433
0.75 0.042 0.041
1.0 0.0405 0.030


With Prescales, Max rate = 500kHz

1kHz Max Rate
The max rate that the SHMS can handle is 500kHz. The estimates above were done to show what we can do with prescales.
<x> dAzz with SHMS dAzz with HMS
0.1 0.00189 0.002
0.3 0.0044 0.00345
0.5 0.0174 0.0132
0.75 0.00121 0.0011
1.0 0.00146 0.00107


--E. Long 19:38, 25 April 2013 (UTC)