NPS
From HallCWiki
Main NPS Wiki <-- Primary NPS wiki found here
Device list in EEL/108
- When possible, I'm assigning addresses in the range 129.57.195.100--150.
PXE Booting
- Devices on the 195 subnet are delivered PXE boot options via DHCP by the CNI DHCP server:
next-server 129.57.195.43; # cdaql3 (on 195 subnet in EEL/108) filename "linux-install/pxelinux.0" # boot file
Misc Devices
- hallc-nps-sw-2022 -- Main router
- cdaql3 129.57.195.43 -- main DAQ computer (located in EEL/108)
- nps-ps1 129.57.195.46 -- PortServer (See VTP Portserver Assignments below)
- nps-pdu1 129.57.195.47 -- APC switchable power supply [user: hccuser]
- nps-lv1 (outlet 1); nps-ps1 (outlet 8)]
Low Voltage Crates
- nps-lv1 129.57.195.131 Weiner MPOD crate
High Voltage Crates
- nps-hv1 129.57.195.130 CAEN 4527 Crate
- nps-hv2 129.57.195.132 CAEN 4527 Crate
VME Crates (with module summary)
- nps-crate1 129.57.195.121 VXS crate
- nps-vme1 129.57.195.101
- nps-vtp1 129.57.195.111
- 15 F250 FADCs installed
- nps-crate2 129.57.195.122 VXS crate
- nps-vme2 129.57.195.102
- nps-vtp2 129.57.195.112
- 15 F250 FADCs installed
- nps-crate3 129.57.195.123 VXS crate
- nps-vme3 129.57.195.103
- nps-vtp3 129.57.195.113
- 15 F250 FADCs installed
- nps-crate4 129.57.195.124 VXS crate
- nps-vme4 129.57.195.104
- nps-vtp4 129.57.195.114 (NOT INSTALLED YET)
- 8 F250 FADCs installed (slots 3--10)
- 1 CAEN 1190 TDC (in slot 20) for testing blocklevel > 1
- (To be installed) 'Example' SIS3801 scaler for testing blocklevel > 1
- (To be installed) LED driver modules
NOTE:
- 0th 'full' crate is the SHMS calorimeter crate presently in use in the Hall (SHMS hut)
- nps-vme0 129.57.168.xxx (Likely best to rename the VME SBC to follow general NPS naming scheme for clarity when the time comes.)
- nps-vtp0 129.57.168.xxx (NOT INSTALLED YET)
- It will be configured to use 15 (of its 16 FADCs) and will function identically to the first 3 'full' crates. (The 16th module will be a spare.)
- It will not be coming to EEL/108 (of course).
VTP MAC / Portserver assignments
- nps-vtp1 ce:ba:f0:03:00:ae 129.57.195.141
- nps-crate1
- Portserver: nps-ps1 2001
- nps-vtp2 ce:ba:f0:03:00:af 129.57.195.142
- nps-crate2
- Portserver: nps-ps1 2002
- nps-vtp3 ce:ba:f0:03:00:b0 129.57.195.143
- nps-crate3
- Portserver: nps-ps1 2003
- nps-vtp4 ce:ba:f0:03:00:b1 129.57.195.144 (NOT INSTALLED YET)
- nps-crate4
- Portserver: nps-ps1 2004
- nps-vtp5 ce:ba:f0:03:00:b2 129.57.195.145
- nps-vtp6 ce:ba:f0:03:00:b3 129.57.195.146
Thermal / Humidity / Chiller Control and Readbacks
Using CrIO CompactRIO
- dsg-nps-crio9045 129.57.195.26
- nps-mux 129.57.195.36 (Spare Keysight)