Difference between revisions of "Sep 25 2024"
From HallCWiki
Jump to navigationJump to search (Created page with "Back to Main Page >> Weekly meetings == Agenda == == Notes ==") |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
== Notes == | == Notes == | ||
+ | # SHMS hcvme04, hcvme06 are ready and upgraded to CODA 3 | ||
+ | # Basic DAQ is good to run | ||
+ | # Bill completed the gate and reference time connections for SHMS DC (https://logbooks.jlab.org/entry/4317022) | ||
+ | # Took HMS cosmic runs with adjust trigger time (https://logbooks.jlab.org/entry/4317449): hodoscope and calorimeter good hits look different from previous runs | ||
+ | # Added Aerogel to HV GUI | ||
+ | To do | ||
+ | # Add ET to CODA configuration | ||
+ | # Saturate the DAQ using a high rate pulser to see the maximum data rate | ||
+ | # Would need more than one ERs to achieve higher maximum data rate. | ||
+ | # Bill will keep working on the triggers with cosmic |
Latest revision as of 14:29, 25 September 2024
Back to Main Page >> Weekly meetings
Agenda
Notes
- SHMS hcvme04, hcvme06 are ready and upgraded to CODA 3
- Basic DAQ is good to run
- Bill completed the gate and reference time connections for SHMS DC (https://logbooks.jlab.org/entry/4317022)
- Took HMS cosmic runs with adjust trigger time (https://logbooks.jlab.org/entry/4317449): hodoscope and calorimeter good hits look different from previous runs
- Added Aerogel to HV GUI
To do
- Add ET to CODA configuration
- Saturate the DAQ using a high rate pulser to see the maximum data rate
- Would need more than one ERs to achieve higher maximum data rate.
- Bill will keep working on the triggers with cosmic