== SHMS HB mapping == | == SHMS HB mapping == | ||
+ | * A Lakeshore Hall probe was used for the mapping measurements. The probe has a linearity error as a function of magnetic field which was measured by the company ( [https://hallcweb.jlab.org/wiki/images/1/16/Lakeshore-XHGT-9060-55937-Q1.pdf Table of data]). This linearity error is different for positive and negative field directions. In the data table, the Error = abs(Measured Field)-abs(True Field). So for positive fields True Field = Measured Field - Error. For negative fields True Field = Measured filed + Error. | ||
*[https://hallcweb.jlab.org/wiki/images/5/5e/HB_Field_Mapping.pdf Document and plots] about mapping of B versus I at center of HB bore and the fringe fields in the beam region. | *[https://hallcweb.jlab.org/wiki/images/5/5e/HB_Field_Mapping.pdf Document and plots] about mapping of B versus I at center of HB bore and the fringe fields in the beam region. | ||
** B/I versus I [https://hallcweb.jlab.org/wiki/images/1/1b/Bi_versus_i_hb.pdf plot]. | ** B/I versus I [https://hallcweb.jlab.org/wiki/images/1/1b/Bi_versus_i_hb.pdf plot]. |
Revision as of 11:16, 29 March 2016
Weekly Meetings
- Meetings will be held on Thursdays 11:30-12:30 in F228.
- Next meeting March 31st.
- Join by Bluejeans by phone and computer +1.888.240.2560 (US Toll Free) Enter Meeting ID: 653182486
Notes from March 10th meeting
- Need to check whether the beam pipe will allow one to go to 8-9.5 degrees. (Dave Gaskell will look into this.)
- Get the Q1 mapping information from Steve Lassiter.
- Need to keep track of detector surveys. Contact Bert Metzger.
- Put code for setting field on wiki.
- Double check to understand why there is a 0.7% difference between field at +3900A and -3900A.
- The probe readings had not been corrected.
- Change the effective length of HB by 4% to see effects on the optics. Look at sieve.
- Need table for conversion of all magnet currents to momentum.
- Check with Steve Lassiter about what is exactly thinking of using to mitigate the HB stray fields. Wedges + C-section + iron pipe?
- Work on run plans. (Rolf and Tanja)
Preparation plans
- Magnets.
- Determination of B versus I curve. Develop new code for setting SHMS. Revise HMS field setting codes.
- Cycling procedure especially for HB. Look what is done for the HMS.
- Double check that the magnet field between magnets are superpositions.
- Survey of the positioning of magnets.
- Carbon elastics at 2 pass.
- Survey of collimators, detectors and beamline components.
- Survey of HMS/SHMS pointing at different angles. Look into what was done in the past for HMS commissioning. Determine a list of angles for survey.
- Need to come up with the sieve pattern as a function of quad settings.
- Need to look at use of ideal dipole versus TOSCA field map for HB in COSY.
- Checked with Howard about the quad field centering. The idea that Howard had didn't work. Need to rely on mapping data.
- Integration of detector checkout and optics.
Carbon elastics
- Results from Dipangkar for 1 pass- 2.2 GeV, and 2 pass -4.4 GeV). Measurements at 8-9.5 are doable.
- Need to check whether the beam pipe will allow one to go to 8-9.5 degrees. (Dave Gaskell will look into this.)
SHMS HB mapping
- A Lakeshore Hall probe was used for the mapping measurements. The probe has a linearity error as a function of magnetic field which was measured by the company ( Table of data). This linearity error is different for positive and negative field directions. In the data table, the Error = abs(Measured Field)-abs(True Field). So for positive fields True Field = Measured Field - Error. For negative fields True Field = Measured filed + Error.
- Document and plots about mapping of B versus I at center of HB bore and the fringe fields in the beam region.
- B/I versus I plot.
- Measurements of B at bore center versus I when ramping magnet from 0 to +3900 and back to 0. Then switch polarity and ramp from 0 to -3900 and back to zero.
- plot of absolute difference between B when ramping magnet up and down versus I when going to +3900 and -3900.
- plot of relative difference between B when ramping magnet up and down versus I when going to +3900 and -3900.
- Plot of difference in B between ramping up to +3900 and ramping up to -3900 versus current.
- When ramping to negative currents there was a trip at I= -3139A. Plot of difference between first ramp to -3139A and the second.
- Document and plots about mapping Of B versus z for five different x,y locations (center,top,bottomleft and right) for I = 2000, 3000, 3500 and 3900A.
HMS and SHMS Dipoles
- Pdf version of the HMS field setting program.
SLITS and COLLIMATORS
SHMS Detector Positions
- Detector_Locations_in_SHMS location
SHMS Characteristics
SHMS Drawings of magnets
Study of the SHMS resolution
- Study of the SHMS resolution.
Old HMS information
- HMS Detector survey information,Magnet location surveys
- File with B/I data and plots for dipole and quads.
- Document about dipole field measurements.
- Dipole Transfer Function which compares Tosca and measurements at probe and center.
- Q1 Transfer Function plots and data
- Q2 Transfer Function plots and data
- Q3 Transfer Function plots and data
- Note by Dave Mack on dipole current regulation.
- Plot of Q2 predicted waist versus momentum for effects of zero offset.
- Plots of quads effective field length.
- Plots of quad fringe field.
- Plot X_fp versus momentum.
SNAKE
Moved Snake section here.