Difference between revisions of "Elong-13-04-24"
From HallCWiki
Jump to navigationJump to search(7 intermediate revisions by the same user not shown) | |||
Line 7: | Line 7: | ||
|- | |- | ||
| Target Length || 3 cm | | Target Length || 3 cm | ||
+ | |- | ||
+ | | ''f<sub>dil</sub>'' || 6/20 | ||
+ | |- | ||
+ | | ''p<sub>f</sub>'' || 0.8 | ||
|- | |- | ||
| ''P<sub>zz</sub>'' || 20% | | ''P<sub>zz</sub>'' || 20% | ||
Line 32: | Line 36: | ||
:→ F1 and F2 are now calculated using the [http://arxiv.org/abs/1203.2262 Bosted fits], which lets us extend into a higher x range | :→ F1 and F2 are now calculated using the [http://arxiv.org/abs/1203.2262 Bosted fits], which lets us extend into a higher x range | ||
::→ It is valid for 0<''W''<3.2 GeV and 0.2<''Q''<sup>2</sup><5 GeV<sup>2</sup> | ::→ It is valid for 0<''W''<3.2 GeV and 0.2<''Q''<sup>2</sup><5 GeV<sup>2</sup> | ||
+ | :→ The [[media:azz_rates.pdf | rates note]] has been updated to fix the sign problems that Oscar and Dustin noted | ||
+ | |||
+ | [[Image:2013-04-24-time.png]] | ||
+ | |||
+ | [[Image:2013-04-24-db1d.png]] | ||
Line 37: | Line 46: | ||
[[Image:2013-04-24-1kHz-rates.png|900px|frame|none|alt=1kHz Max Rate|The max SHMS DAQ rate is 1kHz. The estimates above were done to show what we can do without prescales.]] | [[Image:2013-04-24-1kHz-rates.png|900px|frame|none|alt=1kHz Max Rate|The max SHMS DAQ rate is 1kHz. The estimates above were done to show what we can do without prescales.]] | ||
− | --[[User:Ellie|E. Long]] | + | :{| class="wikitable" style="text-align:center; border-collapse:collapse;" border="1" |
+ | | style="width: 200px;" | <''x''> || style="width: 200px;" | d''A<sub>zz</sub>'' with SHMS || style="width: 200px;" | d''A<sub>zz</sub>'' with HMS | ||
+ | |- | ||
+ | | 0.1 || 0.0415 || 0.0448 | ||
+ | |- | ||
+ | | 0.3 || 0.0419 || 0.0415 | ||
+ | |- | ||
+ | | 0.5 || 0.0428 || 0.0433 | ||
+ | |- | ||
+ | | 0.75 || 0.042 || 0.041 | ||
+ | |- | ||
+ | | 1.0 || 0.0405 || 0.030 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | ==With Prescales, Max rate = 500kHz== | ||
+ | [[Image:2013-04-24-500kHz-rates.png|900px|frame|none|alt=1kHz Max Rate|The max rate that the SHMS can handle is 500kHz. The estimates above were done to show what we can do with prescales.]] | ||
+ | |||
+ | :{| class="wikitable" style="text-align:center; border-collapse:collapse;" border="1" | ||
+ | | style="width: 200px;" | <''x''> || style="width: 200px;" | d''A<sub>zz</sub>'' with SHMS || style="width: 200px;" | d''A<sub>zz</sub>'' with HMS | ||
+ | |- | ||
+ | | 0.1 || 0.00189 || 0.002 | ||
+ | |- | ||
+ | | 0.3 || 0.0044 || 0.00345 | ||
+ | |- | ||
+ | | 0.5 || 0.0174 || 0.0132 | ||
+ | |- | ||
+ | | 0.75 || 0.00121 || 0.0011 | ||
+ | |- | ||
+ | | 1.0 || 0.00146 || 0.00107 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | |||
+ | --[[User:Ellie|E. Long]] 19:38, 25 April 2013 (UTC) |
Latest revision as of 14:53, 25 April 2013
Rates Update
→ For the plot below, I assume the following:
Target Material ND3 Target Length 3 cm fdil 6/20 pf 0.8 Pzz 20% E0 11 GeV xBjorken 0.1, 0.3, 0.5, 0.75, 1.0 Q2 Variable θq Calculated θe' Calculated E' Calculated W Calculated
- → Total rates have been included, and are shown plotted with the D2 rates
- → Error bars shown are statistical only
- → I found a slight bug from previous calculations: I was assuming the time output was in hours, but it was in fact in days
- → This has now been corrected, but all previous time calculations are under-estimated by a factor of 24
- → F1 and F2 are now calculated using the Bosted fits, which lets us extend into a higher x range
- → It is valid for 0<W<3.2 GeV and 0.2<Q2<5 GeV2
- → The rates note has been updated to fix the sign problems that Oscar and Dustin noted
No Prescales, Max rate = 1kHz
<x> dAzz with SHMS dAzz with HMS 0.1 0.0415 0.0448 0.3 0.0419 0.0415 0.5 0.0428 0.0433 0.75 0.042 0.041 1.0 0.0405 0.030
With Prescales, Max rate = 500kHz
<x> dAzz with SHMS dAzz with HMS 0.1 0.00189 0.002 0.3 0.0044 0.00345 0.5 0.0174 0.0132 0.75 0.00121 0.0011 1.0 0.00146 0.00107
--E. Long 19:38, 25 April 2013 (UTC)