Difference between revisions of "Pol He-3 Target Information"
From HallCWiki
Jump to navigationJump to searchLine 118: | Line 118: | ||
* [https://hallaweb.jlab.org/wiki/index.php/Target_Lab_Main EEL Target Lab Main Page] | * [https://hallaweb.jlab.org/wiki/index.php/Target_Lab_Main EEL Target Lab Main Page] | ||
* [https://hallaweb.jlab.org/wiki/index.php/Hall_A_He3_Polarized_Target 2008/9 Hall A Pol 3He Target Page] | * [https://hallaweb.jlab.org/wiki/index.php/Hall_A_He3_Polarized_Target 2008/9 Hall A Pol 3He Target Page] | ||
+ | |||
+ | === Target CAD Files/Photos === | ||
+ | * [https://misportal.jlab.org/jlabDocs/search.seam Document Control Group] | ||
+ | ** Use 'Advanced Search Options': Category='hall c', Document number='67507' | ||
+ | |||
+ | * Selected Target Shop Drawings | ||
+ | ** [[Media:polhe3-target-files/67507-00047.pdf|Target Ladder]] | ||
+ | ** [[Media:polhe3-target-files/67507-00051.pdf|Target Oven]] | ||
+ | ** [[Media:polhe3-target-files/67507-00080-1.pdf|Platform and coils]] | ||
+ | ** [[Media:polhe3-target-files/67507-00087-1.pdf|Carbon Foils]] | ||
+ | |||
+ | * [https://drive.google.com/drive/folders/1Fgofz97IFzQ7719Az3cl8vAUy3tfbaQZ?usp=sharing Photos of Target Setup] (google drive link) | ||
+ | * [https://userweb.jlab.org/~metzger/HALL%20C%20A1N%20D2N%20UPDATED%20DRAWINGS/ CAD Models from Bert] | ||
+ | * [https://drive.google.com/drive/folders/19NzT8S-xV6y6AcHtqN6FyNPesMLzz0wy?usp=sharing JT files] | ||
== Manuals == | == Manuals == |
Revision as of 14:15, 13 May 2020
Target Operator Instructions
- PolHe3 Target Training Slides
- Pol He-3 Target Screen Setup / How-tos
- Pol He3 Operational Restrictions (raster, beam current limits, etc)
Checklists
- Checklist before starting Target Work inside the Enclosure
- Backout Checklist after Hall Access for Target Work
- Backout Checklist after Target Work inside Enclosure
Expert Information
Reference Cell
- Pressure calibration data:
- EPICS data:
- Vacuum readback: ADC channel 7 (raw: HcHPE1313ACh7; "calibrated": polhe3:CellVacuum )
- Pressure readback: ADC channel 8 (raw: HcHPE1313ACh8; "calibrated": polhe3:CellPressure )
- 04 Dec 2019 : Reference Cell Summary Document (These calibrations were done before a 1 uF cap was added on 18 Dec 2019 [1])
- 14 Feb 2020 : Reference Cell pressure calibration (14 Feb 2020)
- A little more information: https://logbooks.jlab.org/entry/3788269
- EPICS data:
Cooling Jet Alignment
Alignment jigs and drawings are stored on the box labeled 'Averett 3He Reference Cell Pts'. And the box is on the floor underneath the Hall C counting house printer.
Pol He3 Field Mapping Data
Circular Raster Information
- Raster Status Presentation Mark J., Bob M. (Dec 10, 2018 Collaboration Meeting)
Reboot Switches
- Reboot Switch Operation --How to use reboot switches
- hcreboot5 --Devices in the Pol He3 Rack behind the Green Wall
- hcreboot6 --Devices in the two racks under the pivot
- hcreboot7 --Devices in the two racks under the pivot
Reset Target Ladder Motion Control
Cable/RTD/Signal Maps
NOTE: If you update a map below Click on a the previous hclog entry and either add a comment pointing to your new entry, or use the 'Follow-up' link on the old entry to make a new entry. That will make it easier to track when/why things change.
- Note: There is a dictionary of EPICS PVs with descriptions at
- ~coda/coda/scripts/EPICS_logging/polhe3-epics.txt
- Laser Fiber End RTDs:
- Hardware notes: https://logbooks.jlab.org/entry/3747838
- Final Map: https://logbooks.jlab.org/entry/3747950
- RTDs on cell:
- Visual gauge photo and PV map: https://logbooks.jlab.org/entry/3747509 (12/06/2019 - 03:48)
- RTD head settings: https://logbooks.jlab.org/entry/3747508
Fiber RTD hardware trip points
- Fire Safety RTDs
- HcFiberTemp0, HcFiberTemp1
- max measured about 32C
- set trip to 36C
- Fiber Temperature RTDs
- HcFiberTemp4+ (except for 12, 14 below)
- Max measured of about 32C
- set trip to 46C (as of Jan 14, 2020 -- will set to 36C during next downtime)
- HcFiberTemp12, 14
- Max measured of 40C
- set trip to 46C
Reset instructions for RTD HW trip points • Expert only (Brad or Ethan) [click]
Address 0xF6 FiberTemp0-1: (and the unused 2, 3) Fire safety RTDs (max 36) Address 0xF5 FiberTemp4--7 * max 36 Address 0xF3 FiberTemp8--11 * max 36 Address 0xF4 FiberTemp12-15 * max 46 due to 12, 14
NOTE: power cycling the acromag controller below will trip the laser interlock!
- Set the hardware trip limits
% ssh pi@polhe3pi2 ('hccuser' password) % cd Documents % scls # select 'acromag' entry, then type Ctrl-C to kill the program # Set the limits % for f in 0xf3 0xf5 0xF6; do ./setupAcro -l 36 -a $f; done % for f in 0xf4; do ./setupAcro -l 46 -a $f; done # Reboot the acromag controller using hcreboot6 # Then restart the software by (for example) running bash again % bash
- Verify that the stripcharts are updating again and close the terminal window.
PolHe3 Alarm Handler defaults
These can be reset this way:
% ssh cvxwrks@cdaql1 % cd alarm_handler_polhe3 % ./set_polhe3_defaults
Type in the number for the fields you wish to reset and hit return.
Additional Documentation
Target CAD Files/Photos
- Document Control Group
- Use 'Advanced Search Options': Category='hall c', Document number='67507'
- Selected Target Shop Drawings
- Photos of Target Setup (google drive link)
- CAD Models from Bert
- JT files