Difference between revisions of "Target Field and Kepco Info"
From HallCWiki
Jump to navigationJump to searchLine 2: | Line 2: | ||
==Log Entries== | ==Log Entries== | ||
− | + | * Nov. 26th Kepcos replaced Agilents https://logbooks.jlab.org/entry/3744320 | |
− | + | * Dec. 26th V_in vs Current Calibration for two Kepcos in voltage control mode https://logbooks.jlab.org/entry/3747508 | |
− | + | * Jan. 4th Swapped out Kepco with another Kepco because it was not stable https://logbooks.jlab.org/entry/3758511 | |
− | + | * Jan. 15th Swapped out Kepco with another Kepco because it was running hot and tripping https://logbooks.jlab.org/entry/3764365 | |
− | + | * Feb. 9th Field sweep program updated for Agilent https://logbooks.jlab.org/entry/3780264 | |
− | + | * Feb. 10th Replaced Kepco with Agilent. Rearranged rack for better cooling https://logbooks.jlab.org/entry/3781492 | |
− | + | * Feb. 14th Replaced Agilent with new Kepco. In constant current mode the inductive load option interfered with NMR https://logbooks.jlab.org/entry/3783977 | |
− | + | * March 18th In constant voltage mode, coils need time to warm up https://logbooks.jlab.org/entry/3805990 | |
− | + | * March 22nd New Kepco had odd behavior in voltage mode. Transverse NMR was not working. Left in current mode. https://logbooks.jlab.org/entry/3807357 | |
− | + | * March 22nd Odd behavior explained from above. Noticed possible grounding issues. https://logbooks.jlab.org/entry/3807894 | |
− | + | * March 24th Trouble getting transverse NMR signal. Bad Cable? https://logbooks.jlab.org/entry/3809148 | |
==Coil Currents for D2n== | ==Coil Currents for D2n== | ||
Line 21: | Line 21: | ||
==Plan for returning from COVID shutdown== | ==Plan for returning from COVID shutdown== | ||
− | + | * Follow manufacturers "Check out" procedure for new power supply which was delivered during shutdown | |
− | + | * Measure resistance to ground for both coils | |
− | + | * Install latest new power supply, add additional circuitry | |
− | + | * Test power supplies in both current and voltage control mode | |
− | + | * Look at PS output on scope, with and without RF on. | |
− | + | * Test NMR in both voltage and current mode | |
− | + | * Ensure Labview is ready to go for either configuration | |
==Manuals/Documentation== | ==Manuals/Documentation== | ||
* [[Media:KEPCO.pdf|Note on KEPCO power supplies]] | * [[Media:KEPCO.pdf|Note on KEPCO power supplies]] |
Revision as of 10:28, 1 June 2020
This page is dedicated to all things Target Field related
Log Entries
- Nov. 26th Kepcos replaced Agilents https://logbooks.jlab.org/entry/3744320
- Dec. 26th V_in vs Current Calibration for two Kepcos in voltage control mode https://logbooks.jlab.org/entry/3747508
- Jan. 4th Swapped out Kepco with another Kepco because it was not stable https://logbooks.jlab.org/entry/3758511
- Jan. 15th Swapped out Kepco with another Kepco because it was running hot and tripping https://logbooks.jlab.org/entry/3764365
- Feb. 9th Field sweep program updated for Agilent https://logbooks.jlab.org/entry/3780264
- Feb. 10th Replaced Kepco with Agilent. Rearranged rack for better cooling https://logbooks.jlab.org/entry/3781492
- Feb. 14th Replaced Agilent with new Kepco. In constant current mode the inductive load option interfered with NMR https://logbooks.jlab.org/entry/3783977
- March 18th In constant voltage mode, coils need time to warm up https://logbooks.jlab.org/entry/3805990
- March 22nd New Kepco had odd behavior in voltage mode. Transverse NMR was not working. Left in current mode. https://logbooks.jlab.org/entry/3807357
- March 22nd Odd behavior explained from above. Noticed possible grounding issues. https://logbooks.jlab.org/entry/3807894
- March 24th Trouble getting transverse NMR signal. Bad Cable? https://logbooks.jlab.org/entry/3809148
Coil Currents for D2n
Labview Program Guide
Field Measurements
Plan for returning from COVID shutdown
- Follow manufacturers "Check out" procedure for new power supply which was delivered during shutdown
- Measure resistance to ground for both coils
- Install latest new power supply, add additional circuitry
- Test power supplies in both current and voltage control mode
- Look at PS output on scope, with and without RF on.
- Test NMR in both voltage and current mode
- Ensure Labview is ready to go for either configuration